1. Catalogs
  2. Düker GmbH
  3. Bottom Outlet Valves

Bottom Outlet Valves

Bottom Outlet Valves

Bottom Outlet Valves

Product catalog summary
Overview: Düker bottom outlet valves are renowned for their reliability, long service life, and ease of maintenance. They comply with various standards including the PED Pressure Equipment Directive, TA-Luft, SIL II, and ATEX. All gaskets in contact with the medium meet FDA regulations.
Types and Variations: Four basic types are available: glass lined, glass lined gap-free, stainless steel or Hastelloy, and FireSafe according to EN ISO 10497. Additional options include hand wheel, pneumatic actuators, and block flange configurations.
Design and Maintenance: The design focuses on reducing component diversity, leading to cost savings in spare parts and training. Components like temperature control and limit switches can be easily upgraded. The gap-free version minimizes residue adhesion and simplifies cleaning.
Specifications: The valves feature a PFA valve seat with a stainless steel core, a new TFM1600 bellow, and a stainless steel actuator. They are easy to install and maintain, with features like a flushing nozzle and limit switch compatibility.
FireSafe Valves: These valves are designed to withstand fire for at least 30 minutes, ensuring vessel sealing. They feature a welded steel housing, stainless steel actuator, and a TFM bellow.
Quality Assurance: Düker maintains high-quality standards with certifications in ISO 9001, ISO 14001, ISO 50001, and BS OHSAS 18001. Regular audits and a quality management system ensure product reliability.
Contact Information: Düker GmbH & Co. KGaA, Hauptstraße 39-41, D-63846 Laufach, Tel: +49 6093 87-244, Email: [email protected]
See more

Catalog excerpts

Bottom Outlet Valves-1

GLASS LINING TECHNOLOGIES Bottom Outlet Valves

 Open the catalog to page 1
Bottom Outlet Valves-2

Düker Bottom Outlet Valves – Reliable, Resistant, Durable... Düker bottom outlet valves are known for their reliability and long service During the design of the bottom outlet valves, special attention life together with ease of maintenance and cleaning. They are manufactured was placed on reducing the component diversity within the overall in line with the standards of the PED Pressure Equipment Directive and product range: comply with Technical Instructions on Air Quality Control (TA-Luft), Safety Integrity Level II (SIL II) and ATEX. • This means that a number of components are identical in...

 Open the catalog to page 2
Bottom Outlet Valves-3

Glass Lined Gap-free Bottom Outlet Valves – Safer, Cleaner, more Efficient This gap-free version is especially easy to maintain and clean. In this gene- The “sealing cap” is suitable for all Düker bottom ration the bellows has been reduced to only 6 convolutions. This results in a outlet valves and prevents a gap between the glass significantly lowered risk of adhesions or crystallisation from residue, as well lined outlet connection and valve seat. The various offers easier cleaning. O-ring sizes enable large tolerances to be compensated. Attention: The sealing cap must not protrude into the...

 Open the catalog to page 3
Bottom Outlet Valves-4

Glass Lined Bottom Outlet Valves Bottom Outlet Valves The block flange version opens either into the vessel or Düker stainless steel valves also correspond to the PED and are in line with the air quality control TA-Luft standards. All gaskets are designed with Block Flange in Stainless Steel and Hastelloy to meet the FDA guidelines. The modular design includes: • ealing with valve seat in the glass lined outlet flange S • ellow (6 convolutions and gap-free sealing through B The modular design includes: FEP-covered O-ring) • PT 100 easy to replace (without dismantling of the valve) • ealing with...

 Open the catalog to page 4
Bottom Outlet Valves-5

Glass Lined FireSafe Bottom Outlet Valve Glass Lined Standard Bottom Outlet Valves in line with the latest EN ISO 10497 The name says it all. The Düker “FireSafe” bottom outlet valve securely seals This type is Düker’s standard bottom outlet valve specification. The range of the vessel in the case of fire. application includes temperatures between -60°C and +200°C and operating pressures between -1 bar and +10 bar. When testing to the standard, the valve is filled with water and then exposed to flame. The valve needs to be entirely surrounded by fire. The temperature at valve body ranges from...

 Open the catalog to page 5
Bottom Outlet Valves-6

Accessories for Bottom Outlet Valves Quality on the Highest Level Depending on the individual applications, Düker bottom outlet valves may be The pharmaceutical and chemical industries in particular place great emphasis modified with various accessory parts. Some components, such as on extremely safe and secure handling and production processes. The same the pneumatic actuator or temperature measurement may be up- applies to maintenance and care. graded later if required. Düker technical enamels fulfil all these requirements without compromise. We set the highest requirements for the quality...

 Open the catalog to page 6
Bottom Outlet Valves-7

GLASS LINING TECHNOLOGIES JOBBING FOUNDRY FITTINGS AND VALVES DRAINAGE TECHNOLOGY Düker GmbH & Co. KGaA Hauptstraße 39-41 D-63846 Laufach Tel +49 6093 87-244 Fax +49 6093 87-303 08.15 Specifications subject to change without notice. Internet: www.dueker.de E-Mail: [email protected]

 Open the catalog to page 7
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.