Catalog excerpts
TWO SEPARATE REVENUE FOR AIR AND OIL The mixing valve SMX is the base of Air/Oil progressive modular system. USE ANY TYPE OF LUBRICANT WITH VISCOSITY BETWEEN 15 AND 1000 CST AT A FLUIDS WORKING TEMPERATURE BETWEEN Outlet exclusion plug The Air/Oil dispenser applies the SMX progressive modular dispenser to air/oil system. Air line exclusion plug Modular elements are assembled on sub‐ base that delivers – through special fitting‐ Air/Oil mixture or, as needed, only oil. Fitting for oil only Aria/olio mixer fitting Atomizer fitting MODULAR CONCEPT ECONOMY IN LUBRICANT CONTROL FUNCTION APPLICATIONS ROLLING MILLS ROLLING MILL BOX GUIDE FORMATION OF LOOP HOLDING SUPPORT EXTENSIONS The SMX Air/Oil has two inlets for compressed air connected to both the right and left outlets of the base and one inlet for oil. Oil accurately metered by SMX metering elements through the special “Air‐oil” fitting mounted on the outlets of the base is injected into the air stream. SMX metring Just by changing the fitting on the outlet parts of element SMX metring the SMX Air/Oil and on the lubrication points it element is possible to spray fine (atomizer fitting) or course (spray fitting) Air/Oil mixture on the bearing or to deliver oil (oil fitting) to other friction points such as slides, gears etc.. this means that in one assembly you can have the three possibilities as mentioned above. The Air/Oil system is economic because lubricant quality is accurately metered and is independent from oil viscosity. The “Air/Oil” system is safe to use and is no Fitting health hazard to the operator since no oil mist is Oil inlet produced. AREAS OF AIR/OIL LUBRICATION APPLICATION ‐ ROLLER BEARING STRAIGHTENERS SIZES STRIP TRAIN Lubrication of high speed rotating elements, where a steady distribution of small quantities of lubricant is required and is able to maintain, between moving elements, the lubricating film which tends to be carried off by the high centrifuge power. Lubrication of machinery parts working at high temperatures where the lubricant tends to be dried or burned spray lubrication of chains or gears Lubrication of slides and ways which require a thin film of lubricant all over their surface Lubrication of bearings which need protection for dust infiltration, water or other damaging substances. The mixed air flow creates a slight over pressure inside the lubricated element, preventing the ingress of other polluted bodies Lubrication of point which cannot be reached by traditional lubrication system, where only an oil spray a solve the problem. 1/4
Open the catalog to page 1MODULAR CONCEPT Of the SMX progressive metering elements allows flexibility of the lubrication system to suit the need of the installed project. COMPATIBILITY With DROPSA progressive system installations. The air‐oil distributor is compatible with the traditional SMX systems thus allowing to fit one or more air‐oil distributor on existing installations, it’s only necessary to have a compressed air generator. ECONOMY IN LUBRICANT The oil delivered into air stream is accurately metered according to the effective requirement of the lubrication ...
Open the catalog to page 2fittings to be mounted on base outputs connectors to be mounted on lubrication points (air/oil rough mixture type with terminal spray) (air/oil fine mixture with terminal atomizer) Fittings to be mounted on the base. Oil introduced from the metering chamber of SMX metering unit, is delivered through passage “A” into the oil fitting where it is brought into the compressed air stream which reaches the same fitting through passage “B”. Connector fitting to be mounted on the base. Air passage "B" is closet, thus the ...
Open the catalog to page 3ORDERING INFORMATION 1) Select the code of base assy. According to the number of metering units to be mounted (see table below) 2) Select the codes of SMX metering or units or select the delivery and other technical information 3) Select the code of fittittings mounted on lubrication points (see next page) 4) Select the code of fittings mounted on lubrication points (see next page) (vedi pag. precedente) BASE ASSEMBLY AIR/OIL FOR SIX METERING ELEMENTS Final base Initial base COMPONENTS CHOOSE Description Final Base Intermediate base ...
Open the catalog to page 4All Dropsa spa catalogs and technical brochures
-
FEMTO Pump
5 Pages
-
DL-1 G AND DL-1 O INJECTORS
3 Pages
-
Electric Pumps:Bravo
5 Pages
-
DRAGON X
4 Pages
-
SMART 3
4 Pages
-
Automatic Omega pump
4 Pages
-
OMEGA pump
4 Pages
-
Dragon X
4 Pages
-
Locopump S3
2 Pages
-
SMX Stainless steel
4 Pages
-
nP - nano Progressive
5 Pages
-
Products overview
9 Pages
-
Mini-SUMO II Atex
3 Pages
-
SUMO II ATEX
3 Pages
-
C2248P
4 Pages
-
MaxClean
1 Pages
-
Mini-SUMOII
4 Pages
-
MaXtreme
6 Pages
-
C2175P
2 Pages
-
Hydraulic pump
2 Pages
-
MiQueLEXT
4 Pages
-
SMART OIL 2
1 Pages
-
7LT oil reservoir
1 Pages
-
PoliPUMP-Eco
2 Pages
-
MaXtreme Oil
2 Pages
-
PRM pump
3 Pages
-
C2001PE WK 28/07
2 Pages
-
C2204P
4 Pages
-
LocopumpS2
2 Pages
-
C2045PE
2 Pages
-
CannonPump
2 Pages
-
High pressure hand pump
2 Pages
-
MiQueL EXT - External pump
4 Pages
-
PoliPUMP FP
4 Pages
-
Dividers- DM-Modular valve
6 Pages
-
Magnom CP
2 Pages
-
Drain Reservoir
2 Pages
-
Smart Oil
1 Pages
-
Dropsa BLUE
1 Pages
-
VIP4 ToolsPro
10 Pages
-
Pump Series 12130
2 Pages
-
VIP5 Controller
4 Pages
-
Piccola
2 Pages