The Dranetz HDPQ Xplorer 400 is a power quality analyzer with capabilities for 50Hz, 60Hz, and 400Hz applications, making it suitable for aviation, naval, and military uses. It measures differential voltage and current with high precision and captures high-speed transients. The device complies with standards such as IEC 61000-4-30 Class A and IEEE 1159 for power quality, and IEC 61000-4-7 for harmonics.

Measured Parameters
The analyzer measures differential voltage and current with a resolution of 16 bits and supports high-speed transient capture. It operates within a frequency range of 42.5-69Hz and 380-420Hz.

Calculated Parameters
It calculates power and energy parameters such as real power, apparent power, reactive power, power factor, and energy demand. It also analyzes distortion and harmonics.

Ease of Use Features
The device offers automatic setups, pre-programmed monitoring modes, and dashboards for power quality, demand, and energy. It includes AnswerModules for diagnosing power quality issues.

Standards Compliance
The Xplorer 400 complies with various standards for power quality, harmonics, and voltage flicker, including IEC and IEEE standards.

General Specifications
The device is compact and lightweight, with a 7-inch color touch display. It operates in temperatures from 0 to 50°C and has a battery life of 2.5 hours on a full charge.

Communications
It supports Ethernet, wireless, USB, and Bluetooth communications, allowing remote control and data access via apps and VNC.

Applications
The Xplorer 400 is suitable for power quality surveys, transient studies, fault recording, motor testing, and harmonic analysis. It is designed for both traditional and 400Hz applications.

Advanced Capabilities
The device captures high-speed transients and includes AnswerModules for automatic identification of power quality problems. It offers safe remote accessibility and an intuitive user interface.

Demand and Energy Surveys
The analyzer provides extensive demand and energy monitoring capabilities, with dashboards for real-time and accumulated readings. It supports billing reports and data upload to Dran-View 7 software for analysis.

Reporting & Analysis
The Dranetz HDPQ Mini Report tool allows for easy screen snapshots and report compilation. Dran-View 7 software enhances data visualization and analysis, offering advanced analytical capabilities.
See more

Catalog excerpts

Dranetz HDPQ® Xplorer 400 Brochure-1

SPECIFICATIONS MEASURED PARAMETERS STANDARDS COMPLIANCE (50/60Hz only) (4) Differential Voltage: 512 s/c @50/60Hz (1MHZ for High Speed Transient), 16 bit resolution. 64 S/C @400Hz 0-1000Vrms, AC/DC, ±0.1 % reading, <40V ±0.5%FS IEC 61000-4-30 Class A: 60-1000Vrms, ±0.1 % of Udin, range of 10% ~ 150% of Udin. (50/60Hz only) Transients - High Speed: 10-2000Vpk, +/- 10% of reading, +/- 0.5%FS Transients: 0-1500Vpk, ±0.2 % of Udin (4) Current (rms): 512 s/c (1MHZ for HS Trans.), 16 bit resolution. 64 S/C @400Hz Range probe dep., AC/DC, +/- 0.1% reading +/- 0.05% FS Transients - High Speed: Range probe dep., 10% of Reading +/- 0.5%FS Transients: Range probe dep., ±0.2 % of Udin IEC 61000-4-30 Class A: Edition 2 (2008) IEEE 1159: 2009 Voltage Flicker IEC 61000-4-15: Edition 2 (2010) IEEE 1453: 2011 CALCULATED PARAMETERS GENERAL SPECIFICATIONS Power/Energy - 1 Second sampling Real Power (W) - P: meets 0.2S requirements, range probe dep. Apparent Power (VA) - S: meets 0.2S requirements, range probe dep. Reactive Power (var) - Q: meets 0.2S requirements, range probe dep. Power Factor (W/VA) -”true” 1 to 0 to -1 Displacement PF 1 to 0 to -1 Demand (in W): meets 0.2S requirements, range probe dep. Energy (in Wh): meets 0.2S requirements, range probe dep. Distortion - 200ms, 3 sec, 10 min windows Vthd: 0-100%, +/- 5% for V>=1% Vnom, V Ind Harm: DC, 2-127 @50/60Hz, 2-15 @400Hz, +/- 5% for V>=1% Vnom Ithd: 0-100%, +/- 5% for I>=1% Vnom, I Ind Harm: DC, 2-63@50/60Hz, 2-15 @400Hz, +/- 5% for I>=1% Vnom Size (10”w x 8”h x 2.75”d) (25.4cm x 20.3cm x 7.00 cm) Weight: 1.9 kg, 4.3lbs Operating temperature: 0 to 50 deg C Storage temperature: -20 to 60 deg C Humidity: 10-90% non condensing Clock accuracy and resolution Internal: +/- 1 sec/day at 25deg C NTP: +/-10 msec GPS: +/-1 msec AC Adapter: 90-264Vac 50/60Hz Battery capacity and charge time: 2.5 hours run time on full charge (3 hour charge time) Memory size: 4GB Display: 7” WVGA color graphic, icon based touch LCD, LED Backlit Languages: English, German, Spanish, French, Italian, Swedish, Finnish, Polish, Chinese (traditional and simplified), Thai, Korean Automatic Setups Pre-programmed monitoring modes AnswerModules®- Sag/Dip Directivity, PF Cap, Motor (50/60Hz only) Dashboards - PQ, Demand & Energy Simultaneous PQ, Demand & Energy Mini Report, Screen Snapshots Dranetz HDPQ Xplorer 400 Brochure.indd 1-2 Power Quality Ethernet, 802.11 b/g/n Wireless USB On the Go Bluetooth via USB adapter VNC remote control Android® & Apple® App Take Dranetz PQ Monitoring to the Air or Sea with 400Hz Capability! tel 732.287.3680 • fax 732.248.1834 • 1000 New Durham Road • Edison, New Jersey 08818 USA Dranetz HDPQ AnswerModule and Dranview are trademarks of Dranetz. ©2015 Dranetz. All rights reserved. Printed in the United States. Specifications are subject to change without notice.

 Open the catalog to page 1
Dranetz HDPQ® Xplorer 400 Brochure-2

Take Dranetz PQ Monitoring to the Air or Sea! Applications – 50Hz, 60Hz & 400Hz Capabilities! The Dranetz HDPQ Xplorer 400 takes PQ, Demand and Energy monitoring to new heights by adding 400Hz monitoring capabilities to the already powerful Dranetz HDPQ Xplorer. Applications, such as aviation, naval, military and others require 400Hz capabilities that are not available in most PQ and Energy analyzers that can only measure 50/60Hz. The Dranetz HDPQ Xplorer 400 was designed with 400Hz applications in mind, but it is also an all-purpose tool that can be used for any traditional 50/60Hz application....

 Open the catalog to page 2

All Dranetz catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.