Open the catalog to page 1Standard Signal AI Module DMB 96100Measuring input for Standard Signals, Modbus RTU The Modbus Standard Signal AI Module is used for electrical isolated conversion of unipolar standard voltage and current signals. A transmitter power supply is provided for the operation of 2-wire and 3-wire transmitters. All parameters can be set via the Modbus RTU interface and via a programming socket behind the front panel. A free PC configuration software also offers extended setting options and extensive diagnostic functions during operation. A subset of the most common settings is also available via DIP...
Open the catalog to page 2Technical Data Input Input signal Input resistance Overload Transmitter supply Module addressing Response delay Baud rate Configuration Connectivity Indication Measuring range General Data Measuring error Temperature coefficient1' Resolution Sampling rate 16 V (open circuit/short circuit < 22 V / 35 mA) Test voltage Working voltage2' (Basic insulation) Protection against dangerous body currents2' Ambient temperature Power supply EMC3' Parity: Even, Odd, None 2 stop bits, None 1 stop bit Up to 247 DRAGO Modbus devices without additional repeater (1 /8 Load) Yellow LED on front panel 0 to 115 %...
Open the catalog to page 34 Channel AI Module DMB 962004 Fully Isolated Analog Inputs, Modbus RTU The Modbus 4 Channel Al Module provides four fully isolated, independently configurable inputs. Each input can be configured as either a current input or a voltage input. Various filter functions can be used to suppress interferences. All parameters can be set via the Modbus RTU interface and via a programming socket behind the front panel. A free PC configuration software also offers extended setting options and extensive diagnostic functions during operation. A subset of the most common settings is also available via DIP...
Open the catalog to page 4Technical Data Input Input signal Input resistance Overload Module addressing Baud rate Configuration Connectivity Measuring error Temperature coefficient1' Resolution Test voltage Working voltage2' (Basic insulation) Protection against dangerous body currents1' Ambient temperature Voltage Current Parity: Even, Odd, None 2 stop bits, None 1 stop bit Response delay: 1 to 1 000 ms Up to 247 DRAGO Modbus devices without additional repeater (1 /8 Load) 3 kV AC, 50 Hz, 1 min. All channels against each other and against Modbus/power supply 600 V AC/DC for overvoltage category II and pollution degree...
Open the catalog to page 54 Channel 2AI/2AO Module DMB 964004 Fully Isolated Analog I/O Channels, Modbus RTU The Modbus 4 Channel Analog Module provides four fully isolated, independently configurable channels. Two inputs can be configured as current or voltage inputs. In addition, these can be configured as digital inputs or digital outputs (open collector). Two outputs can be configured as current or voltage outputs. In addition, these can be configured as digital outputs (active logic 0/10 V). All parameters can be set via the Modbus RTU interface and via a programming socket behind the front panel. A free PC configuration...
Open the catalog to page 6Technical Data Input Input signal Input resistance Overload Additional function Output signal DO: Open collector switching output, . 30 V / . 100 mA (drop voltage < 2V) Voltage Current Residual ripple Additional function Module addressing Baud rate Configuration Connectivity Measuring error Temperature coefficient1' Resolution Test voltage Working voltage2' (Basic insulation) Protection against dangerous body currents1' Ambient temperature DO: active switching output 0/10 V Parity: Even, Odd, None 2 stop bits, None 1 stop bit Response delay: 1 to 1000 ms Up to 247 DRAGO Modbus devices without...
Open the catalog to page 7Universal AI/DI Module DMB 96500Universal Measuring Input, Modbus RTUThe Modbus Universal AI/DI Module is intended to be used with a wide range of industrial sensors. All parameters can be set via the Modbus RTU interface and via a programming socket behind the front panel. A free PC configuration software also offers extended setting options and extensive diagnostic functions during operation. A subset of the most common settings is also available via DIP switches. The measuring value can be read over the Modbus RTU (RS485) interface. The 2-way isolation guarantees reliable decoupling of the...
Open the catalog to page 8Technical Data Input Resistor / Pot 5000, 5k0, 20kO, 100kQ Measuring rate Resitor / Pot Connection /Sensor current /Cable resistance 0.05 % full scale 1 00 ppm/K Measuring rate Cold junction compensation Measuring rate Current / Voltage Input resistance Measuring modes Input signal Push-Pull level /NPN pullup /PNP pulldown Module addressing Baud rate Configuration Connectivity Test voltage Working voltage2) (Basic insulation) Protection against dangerous body currents2) internal, external Pt1 00 / PT1 000, programmable, uncompensated 0.05 % full scale 1 00 ppm/K 0.05 % full scale 1 00 ppm/K 0.05...
Open the catalog to page 94 Channel DI/DO Module DMB 967004 independent controllable digital I/O channels, Modbus RTU The Modbus 4-channel DI/DO module provides four independently configurable inputs/outputs. The inputs can be used either as a binary, frequency or counter input with three selectable input levels. The open collector outputs are usable as binary, frequency, pulse or PWM outputs. Various time functions can be used to set the switching behaviour. All parameters can be set via the Modbus RTU interface and via a programming socket behind the front panel. A free PC configuration software also offers extended...
Open the catalog to page 10Technical Data Input Input level Input voltage Functions Frequency: 0.1 Hz to 1 kHz Min. pulse width: 0.5 ms Output Output type Max. voltage / current Residual voltage Functions Open collector 32 V DC, 100 mA < 1.5 V DC Binary Pulse: 1 to 60000 /min Min. pulse width: min. 0.3 ms , programmable Modbus Protocol Module addressing Baud rate Configuration Connectivity General Data Indication Test voltage Protection against dangerous body currents1' Ambient temperature Parity: Even, Odd, None 2 stop bits, None 1 stop bit Response delay: 1 to 1000 ms Up to 247 DRAGO Modbus devices without additional...