Signal Converters | Isolation Amplifiers DRAGO | AUTOMATION engineered for your success Isolation Amplifiers
Open the catalog to page 1The Isolation Amplifier DB 6200 is used for isolation and conversion of bipolar and unipolar industrial signals. Due to the easy selection of the input and output ranges, the new universal power supply and the ultra-small housing the Isolation Amplifier is suitable for flexible use. High reliability and Protective Separation are further characteristics that make the DB 6200 unrivaled. The order key allows you to select the desired input and output ranges to which the unit will be adjusted at the factory before delivery. These can be easily reconfigured at any time by means of DIP switch settings....
Open the catalog to page 2Technical Data Input Input signals (terminal/switch selectable) Input resistance Input capacitance Overload Output signals (switch selectable) Linear transmission range Residual ripple General Data Transmission error Temperature coefficient1 Zero/Span compensation Cut-off frequency -3 dB (switchable) Response time T99 Test voltage Working voltage1 2 3 (Basic Insulation) Protection against electrical shock2 Ambient temperature Power supply Voltage Current Voltage limitation via 30 V Z-Diode, < 200 mA Voltage Current 4 kV AC, 50 Hz, 1 min. Input against output against power supply 1 000 V AC/DC...
Open the catalog to page 3Filter Isolation Amplifier DB 6230Isolation and Conversion of Industrial Signals with Configurable Filter FunctionThe Filter Isolation Amplifier DB 6230 is used for isolation and conversion of bipolar and unipolar industrial signals. Due to the easy selection of the input and output ranges, the new universal power pack and the ultra-small housing the Isolation Amplifier is suitable for flexible use. High reliability and Protective Separation are further characteristics that make the DB 6230 unrivaled. The order key allows you to select the desired input and output ranges to which the unit will...
Open the catalog to page 4Technical Data Input Input signals (terminal/switch selectable) Input resistance Input capacitance Overload Output signals (switch selectable) Linear transmission range Residual ripple General Data Transmission error Zero/Span compensation Filter function Cut-off frequency -3 dB (switchable) Response time T99 Test voltage Working voltage2) (Basic Insulation) Protection against electrical shock2) Voltage Current Voltage limitation via 30 V Z-Diode, < 200 mA Voltage Current Ambient temperature Power supply 4 kV AC, 50 Hz, 1 min. Input against output against power supply 1 000 V AC/DC for overvoltage...
Open the catalog to page 5Inverse Isolation Amplifier DB 6250Isolation and Conversion ofIndustrial Signals with Inverse Characteristic The Inverse Isolation Amplifier DB 6250 is used for isolation and conversion of industrial signals with inverse characteristic. Due to the easy selection of the input and output ranges, the new universal power pack and the ultra-small housing the Isolation Amplifier is suitable for flexible use. High reliability and Protective Separation are further characteristics that make the DB 6250 unrivaled. The order key allows you to select the desired input and output ranges to which the unit...
Open the catalog to page 6Technical Data Input Input signals (terminal/switch selectable) Input resistance Input capacitance Overload Output signals, inverse characteristic (switch selectable) Linear transmission range Residual ripple General Data Transmission error Temperature coefficient1 Zero/Span compensation Cut-off frequency -3 dB (switchable) Response time T99 Test voltage Working voltage1 2 3 (Basic Insulation) Protection against electrical shock2 Ambient temperature Power supply Voltage Current Voltage limitation via 30 V Z-Diode, < 200 mA Voltage Current 4 kV AC, 50 Hz, 1 min. Input against output against power...
Open the catalog to page 7Passive Isolator DH 1000Separation of 0(4) ... 20 mA Standard Signals The input loop-powered isolator DH 1000 provides galvanic separation for 0(4) ... 20mA standard signals, while transferring the measurement signal to the output with a high degree of accuracy. In this way, the unit avoids interference voltage carry-over, effectively suppressing interference. The very low drop voltage of 2.0 V, a high level of accuracy and a compact design all work together to make the DH 1000 the first choice in system design. The slim housing with 12.5 mm width for one or two channels saves space in your switch...
Open the catalog to page 8Technical Data Input Cut-off frequency -3 dB_100 Hz at 500 Q load Response time T99 5 ms at 500 Q load Residual ripple < 10 mVrms < 0.03 % of measured value / 100 Q load Temperature coefficient1 < 15 ppm/K of measured value / 100 Q load DH 101X Test voltage 1.5 kV AC, 50 Hz, 1 min. all circuits against one another DH 102X Test voltage 4 kV AC, 50 Hz, 1 min. all circuits against one another Working voltage2) (Basic 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61 01 0-1 Protection against electrical Protective separation according to EN 61140 by reinforced insulation...
Open the catalog to page 9The Isolation Amplifier DK 8000 is used for isolation and • Customer-Specific Solutions conversion of customer-specific industrial signals. Special Input and output range on request When it comes to individualized solutions, the know-how advantage of our development team stands ready to serve. This allows us to offer customer-specific solutions with the proverbial DRAGO quality in the shortest possible time; solutions which, as a result of individualized consultation, optimally meet all customer needs, including their economic ones. The slim housing with 12.5 mm width saves space in the switch...
Open the catalog to page 10Input signal Customer-specific technical data as orders (see label) Input resistance Current input approx. 25 Q (depends on measuring range) Voltage input approx. 1 MQ (depends on measuring range) Overload Max. 120 % of final value Output signal Transmission range Residual ripple General Data Transmission error Temperature coefficient1 Zero/Span Adjustment Cut-off frequency (-3 dB) Test voltage Working voltage2) (Basic Insulation) Ambient temperature technical data as orders (see label) Typical 0.1 % full scale (max. 0.3 %, depends on measuring range) 4 kV AC, 50 Hz, 1 min. input against output...
Open the catalog to page 112 Pages
2 Pages
2 Pages
2 Pages
2 Pages
115 Pages
14 Pages
18 Pages
16 Pages
32 Pages
116 Pages
2 Pages
2 Pages