DH 1000
1 /2Pages

DH 1000

DH 1000
1 /2Pages

Catalog excerpts

DH 1000-1

Passive Isolator DH 1000Separation of 0(4) ... 20 mA Standard Signals The input loop-powered isolator DH 1000 provides galvanic separation for 0(4) ... 20mA standard signals, while transferring the measurement signal to the output with a high degree of accuracy. In this way, the unit avoids interference voltage carry-over, effectively suppressing interference. The very low drop voltage of 2.0 V, a high level of accuracy and a compact design all work together to make the DH 1000 the first choice in system design. The slim housing with 12.5 mm width for one or two channels saves space in your switch cabinet and facilitates by the practical plug-in screw terminal blocks the assembly. The DH 10X2 requires only 6.3 mm DIN-rail space per channel. Intelligent design and their consequential avoidance of highly integrated components result in extremely long service lives and reliability without any falsification of the measurement signal. To protect both maintenance personnel as well as downstream equipment against impermissibly high voltages, the DH 1 02X offers Protective Separation with a test voltage of 4 kV AC. The DH 1000 requires no additional power supply since the auxiliary power is obtained from the input signal without distorting it. This not only saves costs during installation, but also increases reliability. • Galvanic isolation across input and output Protection against erroneous measurements due to parasitic voltages or ground loops • No power supply required Saving costs since wiring is reduced and line influences are omitted • Extremely compact design, 1 - and 2-channel versions Only 6.3 mm DIN-rail per channel • High accuracy No falsification of measured signal • Protective Separation Protects service personnel and downstream devices against impermissibly high voltage • Maximum reliability No maintenance costs • 5 Years Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender) DRAGO Signal Converter - Isolation Amplifiers - www.drago-automation.de

 Open the catalog to page 1
DH 1000-2

Technical Data Input Cut-off frequency -3 dB_100 Hz at 500 Q load Response time T99 5 ms at 500 Q load Residual ripple < 10 mVrms < 0.03 % of measured value / 100 Q load Temperature coefficient1 < 15 ppm/K of measured value / 100 Q load DH 101X Test voltage 1.5 kV AC, 50 Hz, 1 min. all circuits against one another DH 102X Test voltage 4 kV AC, 50 Hz, 1 min. all circuits against one another Working voltage2) (Basic 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61 01 0-1 Protection against electrical Protective separation according to EN 61140 by reinforced insulation...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.