Signal Converters | Isolation Amplifiers DRAGO | AUTOMATION engineered for your success Isolation Amplifiers Complete Catalog www.drago-automation.de
Open the catalog to page 1DRAGO | AUTOMATION DRAGO Automation GmbH, Waldstr. 86-90, 13403 Berlin, GERMANY
Open the catalog to page 2DRAGO Automation GmbH DRAGO Automation GmbH has been manufacturing and supplying high quality signal converters and transmitter since 2002. We supply particularly durable and reliable components for automation technology, both for the standard sector and solutions to meet individual requirements. We want our customers to be able to work with even greater economic efficiency. Our standardised DRAGO device concept and our universal measurement range conversion make it easy to use our devices in applications and they are available worldwide. Special DRAGO switching techniques, the use of DRAGO protective...
Open the catalog to page 3DRAGO | AUTOMATION DRAGO Automation GmbH, Waldstr. 86-90, 13403 Berlin, GERMANY
Open the catalog to page 4Application Example Loop-Powered Isolators The loop-powered isolator is used for electrical isolation and processing of 0(4) to 20 mA standard signals. The galvanic isolation guarantees reliable decoupling of the sensor circuit from the processing circuit and prevents linked measurement circuits from influencing each other. The Protective Separation with high isolation level provides protection for personnel and downstream devices against impermissibly high voltage. Functioning: The input signal is modulated and then electrically decoupled using a transformer. The isolated signal is then made...
Open the catalog to page 5Passive Isolator DH 18Separation of 0(4) ... 20 mA Standard SignalsThe input loop-powered isolator DH 18 is used for the electrical isolation of 0(4) ... 20 mA standard signals. The DH 18 transfers the measuring signal to the output with a high degree of accuracy and avoids interference voltage carry-over and suppressing interferences effectively. The slim housing with 1 1.2 mm wide for one or two channels saves significant space on the DIN-rail. Intelligent design and their consequential avoidance of highly integrated components result in extremely long service lives and reliability without...
Open the catalog to page 6Technical Data Input Voltage drop Overload Output signal Load Residual ripple < 10 mVrms General Data Transmission error Load error < 0.05 % of measured value / 100 Q load Temperature coefficient1 < 0.004 %/K of measured value / 100 Q load Test voltage 3 kV, 50 Hz all circuits against one another Working voltage (Basic Insulation) 1 2 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010-1 Protection against electrical shock2 Protective separation according to EN 61140 by reinforced insulation in accordance with EN 61010-1 up to 300 V AC/DC for overvoltage category II...
Open the catalog to page 7Passive Isolator DH 1000Separation of 0(4) ... 20 mA Standard Signals The input loop-powered isolator DH 1000 provides galvanic separation for 0(4) ... 20mA standard signals, while transferring the measurement signal to the output with a high degree of accuracy. In this way, the unit avoids interference voltage carry-over, effectively suppressing interference. The very low drop voltage of 2.0 V, a high level of accuracy and a compact design all work together to make the DH 1000 the first choice in system design. The slim housing with 12.5 mm width for one or two channels saves space in your switch...
Open the catalog to page 8Technical Data Input Cut-off frequency -3 dB_100 Hz at 500 Q load Response time T99 5 ms at 500 Q load Residual ripple < 10 mVrms < 0.03 % of measured value / 100 Q load Temperature coefficient1 < 15 ppm/K of measured value / 100 Q load DH 101X Test voltage 1.5 kV AC, 50 Hz, 1 min. all circuits against one another DH 102X Test voltage 4 kV AC, 50 Hz, 1 min. all circuits against one another Working voltage2) (Basic 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61 01 0-1 Protection against electrical Protective separation according to EN 61140 by reinforced insulation...
Open the catalog to page 9Passive Isolator DH 11000Separation of 0(4) ... 20 mA Standard Signal CC The input loop-powered isolator DH 11000 provides galvanic separation for 0(4) ... 20 mA standard signals, while transferring the measurement signal to the output with a high degree of accuracy. The unit avoids interference voltage carry-over and effectively suppressing parasitic noise. The very low drop voltage of 2.3 V and the high level of accuracy work together to make the DH 1 1 000 the first choice in system design. Intelligent design and their consequential avoidance of highly integrated components result in extremely...
Open the catalog to page 10Technical DataInput Input signal 0(4) ... 20 mA Residual ripple < 10 mVrms < 0.05 % of measured value / 100 Q load Test voltage 3 kV AC, 50 Hz, 1 min. all circuits against one another Working voltage2) (Basic insulation) 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010-1 Protection against electrical shock 2) Protective separation according to EN 61140 by reinforced insulation in accordance with EN 61010-1 up to 300 V AC/DC for overvoltage category II and pollution degree 2 between all circuits Ambient temperature Operation - 25 to + 70 °C (— 13 to + 158 °F) Approvals...
Open the catalog to page 11DRAGO | AUTOMATION DRAGO Automation GmbH, Waldstr. 86-90, 13403 Berlin, GERMANY
Open the catalog to page 12Application Example The repeater power supply is used to supply and separate 2-and 3-wire transmitters and active sensor signals. Additionally the measuring input accepts active 4 to 20 mA signals from 4-wire transmitters. The galvanic isolation across input and output protects against erroneous measurements due to parasitic voltages or gorund loops. To protect both maintenance personnel as well as downstream equipment against impermissibly high voltages, the repeater offers Protective Separation in according to EN 61140. The input signal is modulated and then electrically decoupled using a transformer....
Open the catalog to page 13Passive Transmitter Repeater DC 58Powering and Isolation of 2-wire transmitters The Passive Transmitter Repeater DC 58 is used for powering of 2-wire transmitters and isolation of 4 ... 20 mA standard signals. The 24 V power from the control system is transferred to the 2-wire transmitter with low voltage drop. The transmitter loop current is available galvanic isolated on output of the DC58. Additionally the measuring input accepts active 4 ... 20 mA signals from 4-wire transmitters. For communication with HART-Transmitters the internal 250 Ohm resistor on terminal 4 can be used. The slim housing...
Open the catalog to page 142 Pages
2 Pages
2 Pages
2 Pages
2 Pages
115 Pages
14 Pages
18 Pages
22 Pages
16 Pages
32 Pages
2 Pages
2 Pages