PRECISION USB TEMPERATURE AND HUMIDITY SENSOR The TRH420 is specifically designed for environmental ◌ OEM ◌ Greenhouse ◌ Server rooms ◌ Manufacturing ◌ Pre-certification ◌ LIMS integration ◌ Humidity control ◌ Scientific research ◌ Building automation ◌ Engineering and R&D ◌ Environmental chamber temperature and humidity acquisition. With its factory calibrated, linearized and temperature-compensated digital sensor chip, it is field interchangeable. Thanks to its precision electronics, extremely small variations in temperature and humidity can be detected using a standard USB port. The compact probe eases integration, even in space-constrained locations, and the built-in particle filter provides protection against dust, soot and other contaminants. INSTALLATION TIME UNIQUE SERIAL NUMBER Each unit is assigned a unique serial number allowing for traceability and certification FREE DAQ SOFTWARE Real-time data visualization and logging Parameter Temperature Operating range[1] Accuracy Accuracy Resolution Repeatability Response time Factory calibrated Relative humidity Operating range[3] DATA INTEGRATION Command-line tools for direct data access and integration ○ Virtual COM Port (VCP) communication protocol ○ 3-point user calibration mechanism ALSO AVAILABLE Less than 10 minutes Resolution Repeatability Factory calibrated Filter - Layer 1 Material Filter - Layer 2 Material Efficiency Power supply Polyethylene terephthalate (PET) mesh Current consumption <=18 Mechanical Dimensions See schema below – Colour – Cyan Weight (without USB – 40 cable) Housing and USB cable Temperature operating – 0 to 70 range Humidity operating range Non condensing 10 to 90 Material – ABS IP rating[3] – 51 System galvanic isolation – None USB cable length – 1 (3) Miscellaneous ADC resolution – 16 Long-term stability PTFE membrane Particle size 99.99 ≥200 nm Traceability certificates Powered through a USB port At 5V Temperature compensated Only if cable is not moved/flexed while the temperature is below 0°C. Each sensor is individually conditioned by the manufacturer of the semi-conductor sensor chips, in the best stable condition and their correction coefficients are recorded in each of them. [3] If water condensation or splashing is possible, it is recommended to install the probe pointing down to reduce the risk of water build-up in the sensor. If water splashing is possible, protect the sensor and cable converter using extra precautions. Extra housing may be required depending on the application. [2]
Open the catalog to page 1TRH420 Typical and maximum temperature/humidity tolerances T°C: typical tolerance T°C: maximal tolerance %RH: typical tolerance %RH: maximal tolerance Temperature (°C) & Humidity (%RH) Dracal Technologies inc. www.dracal.com AVAILABLE CHANNEL(S) PRODUCT DIMENSIONS As displayed in our logging software CHANNEL ID* SHT31 Temperature SHT31 Relative Humidity Dew point Humidex Heat index Temperature Relative Humidity Dew point Humidex Heat index Real Real Virtual Virtual Virtual * Channel Id as it appears in QTenki. Virtual channel Id differ in QTenki and usbtenkiget. CAUTION: Keep in mind that electromagnetic...
Open the catalog to page 2