USB TEMPERATURE CONVERTER FOR THERMOCOUPLE - ENHANCED PRECISION Only Type-k and type-j converters are supplied with a connector. INSTALLATION TIME Less than 10 minutes UNIQUE SERIAL NUMBER Each unit is assigned a unique serial number allowing for traceability and certification FREE DAQ SOFTWARE Real-time data visualization and logging DATA INTEGRATION Command-line tools for direct data access and integration OPTIONS ◌ Virtual COM Port (VCP) communication protocol ◌ 3-point user calibration mechanism ALSO AVAILABLE Traceability certificates The TMC200x acquires temperature using a 24-bit analog to digital engine with a built-in noise filter. It performs non-linearity compensation using standard coefficients from the NIST ITS-90 thermocouple database as well as cold-junction temperature compensation, resulting in excellent stability, resolution and accuracy. As a new functionality, the TMC200x provides the user with error status of the thermocouple connection to avoid false readings. Status displays such as “Probe Disconnected” allows the user to intervene when readings are interrupted, and ensures that only relevant readings are recorded. In comparison to the TMC100x, the TMC200x comes with improved precision and resolution. SPECIFICATIONS Parameter TMC200k Thermocouple type Thermocouple operating range[1] Typical accuracy[2] Maximum accuracy TMC200j Thermocouple type Thermocouple operating range[1] Typical accuracy[2] Maximum accuracy TMC200t Thermocouple type Thermocouple operating range[1] Typical accuracy[2] Maximum accuracy TMC200n Thermocouple type Thermocouple operating range[1] Typical accuracy[2] Maximum accuracy TMC200e Thermocouple type Thermocouple operating range[1] Typical accuracy[2] Maximum accuracy Dracal Technologies Inc. All Rights Reserved ◌ Pharmaceutical processes ◌ Food processes ◌ Environmental chamber ◌ Engineering and R&D ◌ Pre-certification ◌ Scientific research ◌ Oven ◌ Temperature detection racks SPECIFICATIONS Value E -100 to – 1000 Junction at 25°C ±0.5 Junction from 25 to 50°C ±1 Parameter ADC resolution Temperature resolution Samples rate Cold junction compensation Buit-in correction Buit-in noise filter Long-term stability Connector compatibility Condition Hot- and Cold-junction – Up to 5 SPS – NIST ITS-90 – – mini 2 and mini 3-pin Power supply Voltage Current Consumption Mechanical Dimensions Powered through a USB port At 5V See drawing below – – Colour Weight Housing Temperature operating range – Humidity operating range [3] Non-condensing Material – IP rating [3] – System galvanic isolation – Miscellaneous Communication – Actual temperature range is probe dependant. [2] Minimum precision over the complete thermocouple operating range. [3] If water condensation is possible, it is recommended to install the probe pointing down to reduce the risk of water build-up in the sensor. If water splashing is possible, protect the sensor and cable conv
Open the catalog to page 1PRODUCT DIMENSIONS Dracal Technologies inc. www.dracal.com CAUTION: Keep in mind that electromagnetic interferences (EMI) may adversely reduce the precision of the sensor. Avoid using this unit close to EMI sources such as or, transformers, high voltage and fluorescent light. NOTE: This product is not waterproof and must be protected if contact with water is possible. TIP: Avoid installing the sensor in a location where considerable vibrations may be present. Large vibrations can introduce extra inaccuracy in the pressure readings. TIP: As for any precision measurement equipment, it is advised...
Open the catalog to page 2