Overview
The LTS 670L is a leakage testing device designed for testing hollow bodies using compressed air or vacuum. It can be operated manually or via external control signals and provides clear test-result indications.

Basic Functions
  • Indicates test results with visible lamps for 'good' or 'reject'.
  • Displays measurement values during four time-based test steps.
  • Includes constant self-testing and diagnostic functions.
  • Features a serial interface for outputting results to a printer or PC.
  • Offers one test program with adjustable limits and step times.

Optional Features
  • Digital inputs and outputs for master control.
  • Enhanced power supply and data protection programming pin.
  • Test and calibration tools available.

Technical Data
  • Electrical supply: 110 - 240 V, 47 - 60 Hz.
  • Pneumatic supply: Clean compressed air, min 1 bar above test pressure, max 7 bar or vacuum.
  • Measurement resolution: 1/20,000 of sensor range.
  • Adjustable times for filling, stabilization, testing, and emptying: 0.05 to 999.95 seconds.
  • Designs: Desktop housing IP 40, available in two sizes.

Test Method
  • Operates using differential-pressure or flow method.
  • Differential-pressure method ranges: ± 20 mbar, with various test-pressure ranges available.
  • Flow method ranges: 0.3 to 125 l/min, with various test-pressure ranges available.

Testing Procedure
  • Initiate test via 'Start' button or external signal.
  • Steps include filling, stabilization, testing, hold, evaluation, and emptying.
  • Test can be stopped or aborted at any stage.

Test Results
  • Green LED indicates 'good' result; red LED indicates 'reject'.
  • Both LEDs indicate test aborted.
  • Results stored until next test or 'Stop' button pressed.

Displays During Test-Run
  • Step counter and measurement display show relevant data for each test step.

Interfaces
  • I/O interface for start, stop/acknowledge, and test-result outputs.
  • Serial interface with specific data parameters for result transmission.
See more

Catalog excerpts

LTS 670L-1

Leakage testing device LTS 670L Basic Functions The leakage testing device LTS 670L can be used for testing leakage on hollow bodies of all kinds, applying either compressed air or vacuum. Assuming the form of a desktop unit it is operated either manually or optionally via external control signals . Designed on one specific test method, it incorporates the following features: - Test-result indication of „good“ and „reject“ results catered for by clearly visible indicator lamps, - Measurement-value indication during four time-based test steps, - numerical indication of the test steps, - Constant self-testing through monitoring of measurement recording signals, - Serial Interface for outputting test results on an inline printer or PC, - Test-run sequence controllable either manually or via external signals (option), - Diagnostic functions, - One test program with adjustable limits and step times. Technical Data Energy Supply: electrical: U = 110 - 240 V, 47 - 60 Hz pneumatic: clean compressed air, min 1 bar above test pressure, max. 7 bar or vacuum Test Pressure and Range of Measurement: corresponding to installed pneumatic module Resolution of Measurement: 1 / 20 000 of sensor range of measurement Adjustable Times: filling time 0,05 ... 999,95 sec Designs: Desktop housing IP 40 - V2 19“, 6U high 235mm x 266mm x 326mm (W x H x D) or - 19“, 3U high 450mm x 140mm x 326mm (W x H x D) Energy supply ports, serial interface, I/O interface and power switch at the backside. Available Optional Features Digital inputs and outputs to a master control Strengthened power supply, Programming pin for protection of the stored data against unauthorized parameter changing ( not available for Flow Method), Test and calibration tools. Dr. Wiesner Steuerungstechnik GmbH [email protected] www.drwiesner.de

 Open the catalog to page 1
LTS 670L-2

Leakage testing device LTS 670L Test Method The leakage testing device LTS 670L operates (corresponding to the installed pneumatic module) according to the - differential-pressure method or - flow method. Differential-pressure Method Range of measurement ± 20 mbar Available test-pressure ranges: -1 ... 0 bar 0 ... 1 bar 0,5 ... 4 bar 0,5 ... 6 bar 1 ... 10 bar Other ranges of test-pressure available on request The adjustment of the test-pressure is done manually at a high precision pressure regulator. Testing Test Procedure - Start the test by pressing the „Start“ button on the front panel or...

 Open the catalog to page 2
LTS 670L-3

Leakage testing device LTS 670L (Input) (Input) (Output) (Output) Displays during the test-run During the different steps the following informations are shown at the display in the front panel. During the step „Filling“: The step counter display is set to 1. At the measurement display the filling pressure is shown. During the step ..Stabilization1': The step counter display is set to 2. At the measurement display the stabilization pressure is shown. During the step „Testing“: The step counter display is set to 3. At the measurement display the pressure decay (relative or differential) or the...

 Open the catalog to page 3

All Dr. Wiesner catalogs and technical brochures

  1. LTS 673

    4  Pages

  2. LTbase

    4  Pages

  3. LTS compact

    2  Pages

  4. Test_leaks

    1  Page

  5. DIN EN 14683

    6  Pages

  6. DIN EN 149

    7  Pages

  7. LTS 670

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.