Power Transmission & Distribution One stop equipments solution Distribution Transformer
Open the catalog to page 112kV Distribution TransformerGeneral Description: • IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Low loss, Low partial discharge, Low temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 60076 & IEEE C57.12, ~ 5000m 12kV Three-phase Two-winding Distribution Transformer with NLTC Voltage and tapping range(kV) No-load On-load Impedance loss (W) loss (W) (%) NINGBO DOWEI ELECTRIC CO., LTD. 608, Lingyun Building...
Open the catalog to page 223kV Distribution TransformerGeneral Description: • IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Low loss, Low partial discharge, Low temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 60076 & IEEE C57.12, ~ 5000m 23kV Three-phase Two-winding Distribution Transformer with NLTC Voltage and tapping range(kV) No-load On-load Impedance loss (W) loss (W) (%) NINGBO DOWEI ELECTRIC CO., LTD. 608, Lingyun Building...
Open the catalog to page 333kV Distribution TransformerGeneral Description: • IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Low loss, Low partial discharge, Low temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 60076 & IEEE C57.12, ~ 5000m 33kV Three-phase Two-winding Distribution Transformer with NLTC Voltage and tapping range(kV) No-load On-load Impedance loss (W) loss (W) (%) NINGBO DOWEI ELECTRIC CO., LTD. 608, Lingyun Building...
Open the catalog to page 4Amorphous Alloy TransformerGeneral Description: • IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • High magnetic susceptibility, Low coercivity • Low loss and Low magnetizing current, Higher stability • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 60076 & IEEE C57.12, ~ 5000m 12kV Three-phase Two-winding Amorphous Alloy Transformer with NLTC tapping range(kV) Vector No-load On-load Impedance group loss (W) loss (W) (%) NINGBO...
Open the catalog to page 53 Pages
3 Pages
3 Pages