video corpo

The systems of ventilating ducts
92Pages

{{requestButtons}}

Catalog excerpts

The systems of ventilating ducts - 1

2006/2007 The systems of ventilating ducts >

Open the catalog to page 1
The systems of ventilating ducts - 3

DOSPEL Co. Ltd. is one of the largest manufacturers of ventilation and air-conditioning equipment and systems. DOSPEL Professional, a member of the DOSPEL Group, specialises in industrial ventilation and air-conditioning systems.Over thirty years' experience, a highly-qualified team of engineers and high quality products make DOSPEL a reliable partner.Many years leadership in domestic market and exports to over 50 foreign markets confirm our superiority in highly advanced technology introduced in our products at competitively low price. The innovative technology of our equipment and...

Open the catalog to page 3
The systems of ventilating ducts - 4

We cooperate with renowned institutions The Chemical Company 2 >

Open the catalog to page 4
The systems of ventilating ducts - 5

3. Certificates 6. Our machine park8. The systems of ventilating ducts10. The systems of ducts with rectangular cross-section 11. Ducts 14. Elbows 17. T-pipes 22. Offset pipes 23. Reducing pipe fittings 24. Outlets 25. Other elements 34. The systems of ducts of continuous cross-section 35. Round shape ducts >

Open the catalog to page 5
The systems of ventilating ducts - 6

.. .. TUV > EN-1886 EN-13053 TUV > Since its onset, DOSPEL Professional has been highly concentrating on providing proper and professional service to its customers. Taking into consideration of client's interest, Company implemented the ISO Quality Management System and was awarded all necessary certificates relating to quality and safety.Hygienic attest - guarantees perfect quality of all materials used for producing of ventilation and air-conditioning equipment and systems.CE - is a declaration of conformity of equipment produced by DOSPEL with the requirements of:- PN-EN 1886 Standard-...

Open the catalog to page 6
The systems of ventilating ducts - 9

Shearing is carried out by an Amada Vipros 368 King hydraulic revolving press with a 58 tool head. The machine handles metal sheets of up to 3000 x 1500 mm and 3.2mm thick. The press has a brushing bench with additional feeding and collection system. HFE 100.3 and HF-50.12 bending brakes are high-quality devices for bending sheets equipped with digital measurement and angle correction. Two independent hydraulic servo drive the units, and intelligent control ensures a smooth and repeatable bending process. The maximum bending length for HFE 100.3 is 3090mm and for HF-50.12 it is 1250mm. >

Open the catalog to page 9
The systems of ventilating ducts - 10

A single-head High-Tech saw is used for the precise cutting of aluminium profiles. The machine is equipped with a compatible profile feeder handling profiles up to 6000 mm in length. It is possible to digitally set the piece length up to 0.01 mm and to regulate the cutting angle. A modern plasma contour band cutter NESSAP 1600 allows for cutting sheets 0.8-20 mm thick, and handles single sheets of up to 1500 x 3000 mm. The device serves cutting mild steel, stainless steel and aluminium. Pneumatic driven machine serves to spot-join sheets by clamping - in accordance with DIN 8593....

Open the catalog to page 10
The systems of ventilating ducts - 11

DOSPEL Professional has extended its production implementing the ventilating ducts made of galvanized iron, thus meeting the clients demands. Thanks to the newest technology, the ventilating circuits made of our ducts and fittings assure the highest class of tightness and they can be used in constructions of high pressure systems. The superior goal of DOSPEL Professional is to offer the highest quality of professional ventilating systems with their attractive prices level.All the fittings are dimensioned according to DIN 18379 standard, assuring the uniformity and repeatability of all their...

Open the catalog to page 11
The systems of ventilating ducts - 13

THE SYSTEMS OF DUCTS OF RECTANGULAR SECTION >

Open the catalog to page 13
The systems of ventilating ducts - 14

Standard length of the ducts produced by DOSPEL Professional is 1500 mm but depending on our client's individual need we are able to produce the ducts with the length of L = 3000 mm. We apply the metal plates of different thickness: 0.6 mm, 0.8 mm, 1.0 mm, and 1.1 mm depending on the width A and height B parameters.Special turning up sides and edges make an additional strength of the duct walls. Depending on the adequate type of duct, we can choose the version between the holes under a grid, plugged from one side, or with one free frame for cutting the ducts according to desirable...

Open the catalog to page 14
The systems of ventilating ducts - 17

* conformity with a plant standard. Description of parameters:A - elbow widthB - the side of an elbow bending (up to 800 mm) > a - angle between an elbow inlet and outletE - straight section at the end of elbow for assembling next item (standard E = 30 mm)F - straight section for assembling next > item (standard F = 30 mm)R - radius of an elbow bend (standard R = 100 mm)Q1 - first frameQ2 - second frame > b r e Description of parameters:A - elbow widthB - the side of an elbow bending (over 800 mm) > a - angle between an elbow inlet and outletE - straight section at the end of elbow for...

Open the catalog to page 17
The systems of ventilating ducts - 18

Description of parameters:A - elbow width, inletB - the side of an elbow bending (up to 800 mm) inletC - elbow width, outlet (standard A=C) > a - angle between an elbow inlet and outletE - straight section at the end of elbow for assembling next item (standard E = > a 30 mm)F - straight section for assembling next item (standard F = 30 mm)R - radius of an elbow bend (standard R = 100 mm)Q1 - first frameQ2 - second frame > b r e Description of parameters:A - elbow width, inletB - the side of an elbow bending ( from 800 mm), inlet a - angle between an elbow inlet and outletC - elbow width,...

Open the catalog to page 18
The systems of ventilating ducts - 19

Description of parameters:A - elbow width, inletB - the side of an elbow bending (up to 800 mm) a - angle between an elbow inlet and outletC - elbow width, outlet (standard A=C)D - the side of an elbow bending, (up to 800 mm), outletE -straight section at > be the end of elbow for assembling next item (standard E =30 mm)F - straight section for assembling next item (standard F= 30 mm)R - radius of an elbow bend (standard R = 100 mm)Q1 - first frameQ2 - second frame > r Description of parameters:A - elbow width, inletB - the side of an elbow bending (up to 800 mm), inlet > a - angle between...

Open the catalog to page 19
The systems of ventilating ducts - 23

Description of parameters:A - width 1, pipe tee outletB - height 1 , pipe tee outletC - width 2, pipe tee outletD - height 2, pipe tree outletG - inlet width (condition A=C=G)H - inlet lengthE straight section at the end of elbow for assembling next > item (standard E = 30 mm)F straight section for assembling next item (standard F = 30 mm)R - radius of a bend 1 (standard R = 100 mm)r - radius of a bend 2 (standard R = 100 mm)V - number of guides 1, outletsv - number > b R r of guides 2, outletsQ1 - first frame (at A and B walls)Q2 - second frame (at C and D walls)Q3 - third frame (at G and...