1. Catalogs
  2. DONGGUAN ITM-LAB MACHINE INC.
  3. Thermal Shock Test Chamber CTS series

Thermal Shock Test Chamber CTS series

Thermal Shock Test Chamber CTS series
1 / 10 PagesView full catalog

Thermal Shock Test Chamber CTS series

Product catalog summary
Product Overview
The document details the specifications and functionalities of the Programmable Thermal Shock Tester, model CTS-100L, manufactured by ITM-LAB MACHINE INC. This equipment is designed for conducting three-temperature zone tests to assess temperature impact and changes within specified performance ranges.

Application and Restrictions
The tester is suitable for three-temperature zone tests but has restrictions on testing flammable, explosive, volatile, corrosive substances, and strong electromagnetic emission sources.

Dimensions
The internal box size is 500mm x 400mm x 500mm, with an external dimension of 1400mm x 1900mm x 1500mm.

Functional Specifications
The equipment operates within a low temperature range of -40 to -10℃ and a high temperature range of +60 to +150℃. It features a preheat temperature range up to +180℃ and a precooling range down to -60℃. Temperature fluctuation is maintained at ≤±0.5℃, and deviation uniformity at ≤±2℃.

Standards Compliance
The tester complies with several standards, including GB/T 2423.1-2001, GB/T 2423.2-2001, and GJB/150 series for temperature tests.

Structural and Material Details
The outer container is made of stainless steel with a mirror paint finish, while the inner box uses SUS304 stainless steel. The insulating layer consists of hardamine lipid foam and glass cotton.

Refrigeration and Heating Systems
The refrigeration system uses mechanical vapor compression with a Hitachi compressor and non-fluoridated HFC R404A + R23 cryogen. The heating system employs finned ni-Cr electric heat pipes.

Control System
The control system features a high-precision resistive touch screen with a 7-inch TFT color LCD. It supports PID + SSR/SCR output modes and includes a comprehensive fault diagnosis and monitoring system.

Defensive Functions
Includes over-temperature protection, fuse-free protective switch, compressor overload protection, and system over-current protection.

Service Conditions
The equipment operates optimally at ambient temperatures between 5℃ and 35℃, with a relative humidity of 85%RH and atmospheric pressure between 80kPa and 106kPa.

After-Sale Service
Offers free training for operators, a one-year warranty, and regular maintenance services.

Execution and Acceptance Standards
Designed and manufactured according to national standards GB/T10586-2006 and GB/T10592-1989, with verification standards GB/T5170.2-1996 and GB/T5170.5-1996.
See more

Catalog excerpts

Thermal Shock Test Chamber CTS series-1

Headquarters address: No.32, Qiaoxin East Road, Qiaotou Town, Dongguan City, Guangdong Province TEL: 86 769 83428055 Programmable Thermal Shock Tester CTS-100L

 Open the catalog to page 1
Thermal Shock Test Chamber CTS series-2

Headquarters address: No.32, Qiaoxin East Road, Qiaotou Town, Dongguan City, Guangdong Province TEL: 86 769 83428055 Product name Programmable Thermal Shock Tester CTS-100L Application restriction description A) Three-temperature zone test of various temperature impact and temperature change within the applicable performance range of the equipment! PS: Change 2 temperature zone or 3 temperature zone test mode with pneumatic air valve switch (note that 2 temperature zone mode has temperature range limit) B) Other uses may cause personnel injuries and damage to machine and equipment! A) Test and...

 Open the catalog to page 2
Thermal Shock Test Chamber CTS series-3

Headquarters address: No.32, Qiaoxin East Road, Qiaotou Town, Dongguan City, Guangdong Province TEL: 86 769 83428055 Temperature heating time of the high temperature box + RT ℃ rose to 150℃ for about 40 minutes, with a full average of non-linearity Cold temperature box cooling time + RT ℃ drops to-60℃ for about 70 minutes, averaging average nonlinearity The 3KG plastic IC does not heat up and contains no test frame! 4.11. Impact transition time 5 Minutes (temperature switch: air valve switch time: 3S) 4.12. High low temperature section Maximum impact time 1.GB / T 2423.1-2001 test A: Low-temperature...

 Open the catalog to page 3
Thermal Shock Test Chamber CTS series-4

Headquarters address: No.32, Qiaoxin East Road, Qiaotou Town, Dongguan City, Guangdong Province TEL: 86 769 83428055 Switch valve A.Divided into high temperature trough, low temperature tank, test tank.High and low temperature trough is used for energy reserves, The test slot is the user use experimental area. B. High and low temperature grooves are separated from the test grooves by switchable valves.Open the corresponding valve automatically upon impact C. Another separate ventilation valve to introduce ambient air during exhaust (room temperature recovery) Air supply temperature measurement...

 Open the catalog to page 4
Thermal Shock Test Chamber CTS series-5

Headquarters address: No.32, Qiaoxin East Road, Qiaotou Town, Dongguan City, Guangdong Province TEL: 86 769 83428055 Air-cooled fin type (32mm inlet and outlet pipe diameter) High efficiency multi-section aluminum alloy fin evaporator (fin thickening type) Denver thermal expansion valve Heron Palace and Denvers, Japan 7.9, Visual fluid lens Quality products of international brands (right picture: dry screening program)) The refrigeration system flow is automatically switched according to different working conditions, and the excess system is cut off in a constant section to achieve energy-saving...

 Open the catalog to page 5
Thermal Shock Test Chamber CTS series-6

Headquarters address: No.32, Qiaoxin East Road, Qiaotou Town, Dongguan City, Guangdong Province TEL: 86 769 83428055 Heating pipe Finned ni-Cr electric heat pipe Control method The controller output signal can control with high precision free contact switch through the SSR solid-state relay Controller and control circuit- -Use CJ7113 controller plus T-type remarks module Control method High-precision resistive touch-type screen The 7 inch TFT color LCD screen.(Resolution: 800 * 480) Enter force Program operation mode. Output mode PID + SSR / SCR automatic positive and reverse bidirectional synchronous...

 Open the catalog to page 6
Thermal Shock Test Chamber CTS series-7

Headquarters address: No.32, Qiaoxin East Road, Qiaotou Town, Dongguan City, Guangdong Province TEL: 86 769 83428055 Soft body function 1. temperature curve: No paper record: built-in record program, controller memory for 24H for 300 days. Automatic generation of a temperature curve file and conversion to an XLS table; 2. Perfect interface: External USB port: can directly connect to the meter printing machine, to achieve local data by line printing, The USB port can easily remit the historical curves and other data with the U disk. External LAN standard network interface: no special server configuration,...

 Open the catalog to page 7
Thermal Shock Test Chamber CTS series-8

Headquarters address: No.32, Qiaoxin East Road, Qiaotou Town, Dongguan City, Guangdong Province TEL: 86 769 83428055 1. Two sets of test rack 2 Set of 50MM test holes 3. Operation manual Maintenance manual 4. The equipment shall be tested by the quality inspection center before leaving the company, and issue an inspection report with a valid period of one year 1. Ambient temperature: 5℃ -35℃; 2. Relative humidity: 85%RH; 3. Atmospheric pressure: 80kPa~106kPa 4. No strong vibration around it 5. supply voltage: 5.1 Connect power supply 380V AC (± 10%), three-phase line + protective ground wire,...

 Open the catalog to page 8
Thermal Shock Test Chamber CTS series-9

Headquarters address: No.32, Qiaoxin East Road, Qiaotou Town, Dongguan City, Guangdong Province TEL: 86 769 83428055 fastest and professional maintenance service (maintenance 12HR reply, 24HR to the factory, problem exclusion) 14. Equipment execution and acceptance standards 1. Design and manufacture in accordance with the national standard GB / T10586-2006 and GB / T10592-1989. Verification standard is according to GB/T5170.2-1996,GB/T5170.5-1996. Tips: GB/T5170.5-1996. Temperature uniformity of GB/T5170.5-1996 refers to the case of empty load; 15. Main material Table brand stainless steel stainless...

 Open the catalog to page 9
Thermal Shock Test Chamber CTS series-10

Headquarters address: No.32, Qiaoxin East Road, Qiaotou Town, Dongguan City, Guangdong Province TEL: 86 769 83428055 C Control Part Controller Europe and the United States Mains switch Leakage protection Heating pipe Thermal relay Inverse phase protector Over temperature protection Solid state relay Electric relay Naked wire-type nickel-chromium allo

 Open the catalog to page 10

All DONGGUAN ITM-LAB MACHINE INC. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.