PG-EG 0006 – 0192 - 1

Process Filtration From Pure to SterilePG-EG 0006 - 0192Single housings MAIN FEATURES & BENEFITS: Donaldson Ultrafilter • Electro polished Ra < 0,8 pm • Complete stainless steel 1.4404 construction • Design in compliance with o FDA CFR-Code of Federal Regulations Title 21 o Framework regulation 1935/2004/EC o Pressure Equipment Directive 2014/68/EU o 3-A Sanitary Standards (Version Superplus) for USA Chemical Pharmaceutical Donaldson Filtration Deutschland GmbH Bussingstr. 1 42781 Haan Germany

Open the catalog to page 1
PG-EG 0006 – 0192 - 2

Process Filtration PG-EG 0006-0192PRODUCT DESCRIPTION PG-EG housings were developed for the purification of pressurised air and other technical gases. Combined in the different Donaldson filter elements they provide an optimised solution for nearly any application. The PG-EG single series is available in 6 different housing sizes with operating flow rates from 7.5 to 360 m3/h (at 1 bar abs.). The housings are equipped with triclamp connections, additional connection types are available on request. The surface is electropolished to Ra < 0,8 pm. Donaldson Ultrafilter All PG-EG single housings...

Open the catalog to page 2
PG-EG 0006 – 0192 - 3

Process Filtration PG-EG 0006-0192 DIMENSIONS HOUSING AND CLAMP CONNECTION - 3 -DIMENSIONS & STEAM STERILISATION Donaldson Ultrafilter

Open the catalog to page 3
PG-EG 0006 – 0192 - 4

Process Filtration PG-EG 0006-0192 TECHNICAL DATA max. operating temperature -25 / +150°C with standard gasket Test pressure: 27 bar Surfaces: etched, passivated and electropolished inside and outside Ra < 0.8pm Classification acc. T o for fluids group 2 Donaldson Ultrafilter

Open the catalog to page 4
PG-EG 0006 – 0192 - 5

Process Filtration PG-EG 0006-0192STEAM STERILISATION Air and gas filter elements can be effectively steam sterilised inside the PG-EG housing. 12rc_ (25CTF) The sterilisation time necessary to reach sterility in the filter depends on the steam temperature. The following are recommended values that have to be adjusted to the specific installation Donaldson Ultrafilter Example for a correct steam-in-place installation providing sufficient condensate removal and steam filtration. Steam temperature and pressure are monitored throughout the sterilisation procedure. Detailed information...

Open the catalog to page 5
PG-EG 0006 – 0192 - 6

Process Filtration PG-EG 0006-0192 GASKET SETS For all housing types of the PG-EG single series a gasket set is available. Spare parts for the housings are available on request. Technical alterations reserved 08/2009 • For information on integrity test equipment or integrity test services, please contact your Donaldson Sales Engineer and visit our website at www.donaldson.com!

Open the catalog to page 6

All DONALDSON catalogs and technical brochures

  1. (P)-GS N

    6 Pages

  2. PLEATED BAGS

    3 Pages

  3. HPK05

    6 Pages

  4. Sensor Vents

    2 Pages

  5. Bulk hP

    4 Pages

  6. LITHOGUARD®

    2 Pages

  7. BSMmax

    2 Pages

  8. Fluid Analysis

    12 Pages

  9. DT filter

    22 Pages

  10. Strainers

    4 Pages

  11. Valves

    6 Pages

  12. Breathers

    14 Pages

  13. TT15/30/60

    2 Pages

  14. SP100/120

    4 Pages

  15. WL16

    4 Pages

  16. W613

    4 Pages

  17. FPK02

    6 Pages

  18. HPK02

    4 Pages

  19. panel filter

    1 Pages

  20. GDX

    4 Pages

  21. Exhaust Product

    186 Pages

  22. Synteq XP

    4 Pages

  23. Ultrac? AK

    2 Pages

  24. ULTRAC A

    2 Pages

  25. Rotary Valves

    10 Pages