Product catalog summary
Introduction
The Donaldson DPF Thermal Regenerator is a component of a two-stage cleaning system for diesel particulate filters (DPFs), designed to eliminate hydrocarbons and unburned particulate matter. It supports various DPF sizes and offers an automated cleaning process.
Pre-Installation Requirements
The unit weighs 500 lbs and should be installed indoors on a hard, flat surface with at least 12 inches of clearance on all sides. It requires a single-phase 30 amp 208 or 240VAC and 15 amp 120VAC power supply, a clean, dry compressed air source at 90 PSI, and an exterior vent connection.
Installation
Place the cabinet on a level surface, connect vent ducting, and ensure proper electrical and air supply connections, adhering to local codes for ventilation and electrical installations.
Operation
The cleaning cycle lasts seven hours, including pre-heating, controlled combustion air pulse heating, and a cool-down cycle. The filter must be pulse cleaned before and after thermal regeneration.
Safety Features
The system includes six safety devices: an open door alert switch, electric door lock, filter placement sensor, air pressure safety switch, high-heat cabinet sensor shutdown, and an emergency stop button.
Filter Tracking
A tagging system is recommended to track filters during the cleaning process. Filters should be reinstalled in the same vehicle to maintain emissions system and engine performance.
Regeneration Process
Remove the filter from the vehicle, pulse clean it, wrap it with a thermal shield, and place it in the regenerator. The thermal shield is essential for maintaining safe temperatures and ensuring effective cleaning.
Warnings
Avoid regenerating filters soaked with oil or fuel to prevent fire or damage to the DPF section. Proper protective gear is recommended when handling filters and ash collection drums.
Specifications and Operation
The manual details the indicator light display on the PLC during start-up and after pressing the "Start" button. It outlines the cleaning cycle modes: heating, cooling, and complete. Safety precautions are advised due to high temperatures.
Cleaning Procedure
The cleaning cycle lasts seven hours, after which the filter can be removed. Protective gloves are recommended due to high temperatures. The filter should be pulse cleaned to remove ash before reuse. Record-keeping of the cleaning process is required for regulatory compliance.
Maintenance
Routine maintenance involves emptying the ash collection drum, following local disposal regulations. A list of spare parts is provided for maintenance and replacement.
Troubleshooting Guide
The manual includes a detailed troubleshooting guide for common issues such as unit start failures, temperature control problems, and operational shutdowns. Solutions involve checking connections, replacing faulty components, and ensuring proper installation.
Warranty
Donaldson provides a two-year warranty on major structural components and a one-year warranty on other components. The warranty excludes damage from corrosion, wear and tear, and improper use.
Contact Information
Technical support contact details are provided for further assistance.
See more

Catalog excerpts

DPF Thermal Regenerator IOM-1

OWNER'S MANUAL Installation, Operation, and Maintenance Information DPF Thermal Regenerator Cleaning System Part No. X007955 This manual is property of the owner. Leave with the unit when installation and start-up are complete. Donaldson Company reserves the right to change design and specifications without prior notice. Do not make any system modifications or adjustments that would alter the original retrofit installation. Modifications may not meet California ARB Executive Order requirements, be considered illegal devices and may result in denial of warranty coverage. Consult your Donaldson certified emissions dealer if you have questions regarding the installation, operation, maintenance or warranty. Illustrations are for reference only as actual product may vary. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

 Open the catalog to page 1
DPF Thermal Regenerator IOM-2

Donaldson Retrofit Emissions System 2  Exhaust Gas Temperature Data Logger Owner's Manual - P480348 Rev 2

 Open the catalog to page 2
DPF Thermal Regenerator IOM-4

Donaldson Retrofit Emissions System Introduction Thank you for purchasing the Donaldson DPF Thermal Regenerator! Donaldson markets two separate cleaning cabinets for routine cleaning and regeneration of diesel particulate filters (DPFs). The first stage is the DPF Pulse Cleaner. The DPF Thermal Regenerator cabinet is the second stage of our DPF Cleaning System – designed to remove hydrocarbons and unburned particulate matter within the filter channels. This unit is designed for Donaldson DPFs, but accommodates multiple sizes of DPFs (up to 14" in diameter and up to 20" in height, 14" w/Thermal...

 Open the catalog to page 4
DPF Thermal Regenerator IOM-5

Donaldson Retrofit Emissions System Cabinet Schematic Exhaust Vent* Diesel Particulate Filter* Control Panel* Door Lock Solenoid*^ Heater Assembly Ventilation Fans* Rear Electrical Field Install* abinet Over- emperature Switch** ressure Switch** Drum Clamp Heater Temperature Control Thermocouple* Cabinet Control Panel Features Start Button Initiates the cleaning cycle. Note: This button does not illuminate. CYCLE MODE Stop button Tamper-proof Temperature Display The information on this display works with built ■ in safety sensors. Do not tamper or remove the display's protective shield. Damage...

 Open the catalog to page 5
DPF Thermal Regenerator IOM-6

Donaldson Retrofit Emissions System Installation followed by a cool down cycle to slowly lower the temperature of the filter and reduce the potential of filter damage from thermal shock. 1. Install the cabinet on a solid, level surface. Make sure to leave a minimum 12" clearance on all sides. Using the leg levelers, adjust until cabinet is level. After the cool down cycle is completed, the diesel particulate filter can be removed from the Thermal Regenerator cabinet and reinstalled in the Pulse Cleaner for a final cleaning of the ash residue. 2. Connect the cabinet vent ducting. The vent ducting...

 Open the catalog to page 6
DPF Thermal Regenerator IOM-7

Donaldson Retrofit Emissions System How to Regenerate A "Dirty" Diesel Particulate Filter A diesel particulate filter removes particulate matter and inorganic ash from diesel exhaust. Under normal operating conditions the filter collects and burns particulate matter. However, inorganic ash from the oil does not burn so it slowly accumulates in the filter. This makes it necessary to remove the ash from the filter on a periodic basis. Diesel particulate filters capture all particulate matter and other volatile compounds generated from a diesel engine. Proper protection gear is recommended for the...

 Open the catalog to page 7
DPF Thermal Regenerator IOM-8

Donaldson Retrofit Emissions System Control PLC Indicator Light Display 7. Open the cabinet door. 8. Use protective gloves when you remove the filter from the heating 9. Release the spring-loaded hooks from the thermal wrap, rotate and pull the wrap out of the cabinet. 10. Remove the filter from the thermal regenerator. 11. Pulse clean the regenerated filter with a DPF pulse cleaner. After Pressing "Start" Regenerated Filter The regeneration cycle may leave ash on the filter. The ash needs to be removed before use. Run the diesel particulate filterthrough a DPF pulse cleaner before Control Panel...

 Open the catalog to page 8
DPF Thermal Regenerator IOM-9

Donaldson Retrofit Emissions System Filter Cleaning Record Keeping Donaldson requires record keeping/tracking for all cleaning occurances. Donaldson Engineering recommends the following data Serial Number EDM Download from Vehicle Person completeing cleaning Donaldson Engineering may request these records in a warranty Service & Maintenance The DPF Thermal Regenerator requires minimal service. On a routine basis, the ash collection drum will need to be emptied. Emptying The Ash Collection Drum 1. Before proceeding - determine local laws and regulations for the 2. Move the container for collected...

 Open the catalog to page 9
DPF Thermal Regenerator IOM-10

Donaldson Retrofit Emissions System Control Circuit 30A BRANCH CIRCUIT PROTECTION AND DISCONNECT MUST BE PROVIDED BY OTHERS AND MUST COMPLY flW NATIONAL AND LOCAL CODES. lii DEVICE LOCATED IN FRONT ENCLOSURE 121 DEVICE LOCATED IN BACK ENCLOSURE ID] DEVICE LOCATED IN DONALDSON CABINET IFi DEVICE LOCATED IN THE FIELD <S TERMINAL IN CONTROL PANEL --------------INDICATES FIELD WIRING 0 SCREW TERMINAL NEAR BOTTQI/ SILICONE BASED PRODUCTS SHALL NOT BE USED ANYWHERE IN THIS ASSEMBLY. ALL FIELD CONTROL WIRE TO 5E MINIMUM 14 AWG 75° C COPPER, UNLESS OTHERWISE NOTED. ALL CONDUIT RUB RATINGS MUST BE EOUA:....

 Open the catalog to page 10
DPF Thermal Regenerator IOM-11

Donaldson Retrofit Emissions System Control Circuit FROM LINE NEXT COLUMN) _OGIC CONTROLLER -iIBH TEMP 11 Donaldson DPF Thermal Regenerator Manual - P480802

 Open the catalog to page 11
DPF Thermal Regenerator IOM-12

Donaldson Retrofit Emissions System Control Circuit Aiy—A FAN#I 12 Donaldson DPF Thermal Regenerator Manual - P480802

 Open the catalog to page 12
DPF Thermal Regenerator IOM-13

Donaldson Retrofit Emissions System Thermal RegeneratorTroubleshooting Guide Donaldson DPF Thermal Regenerator Manual - P480802

 Open the catalog to page 13
DPF Thermal Regenerator IOM-14

Donaldson Retrofit Emissions System Note: Cycle power on the machine during each troubleshooting exercise by pushing the EMERGENCY STOP button and then twisting it to reset it. This will reset the Control Panel and give an accurate indication if the troubleshooting test or repair fixed the issue. 14 Donaldson DPF Thermal Regenerator Manual - P480802

 Open the catalog to page 14

All DONALDSON catalogs and technical brochures

  1. P-EGS

    3  Pages

  2. (P)-GS N

    6  Pages

  3. PLEATED BAGS

    3  Pages

  4. HPK05

    6  Pages

  5. Bulk hP

    4  Pages

  6. ULTRAPOREX SB

    2  Pages

  7. LITHOGUARD®

    2  Pages

  8. BSMmax

    2  Pages

  9. DT filter

    22  Pages

  10. Strainers

    4  Pages

  11. Valves

    6  Pages

  12. Breathers

    14  Pages

  13. TT15/30/60

    2  Pages

  14. SP100/120

    4  Pages

  15. WL16

    4  Pages

  16. W613

    4  Pages

  17. FPK02

    6  Pages

  18. HPK02

    4  Pages

  19. panel filter

    1  Page

  20. GDX

    4  Pages

  21. SYNTEQ XP M/S

    2  Pages

  22. Synteq XP

    4  Pages

  23. Ultrac? AK

    2  Pages

  24. Ultrapoly? PE

    2  Pages

  25. ULTRAC A

    2  Pages

  26. Rotary Valves

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.