SAFEMASTER W group mode
9Pages

{{requestButtons}}

Catalog excerpts

SAFEMASTER W group mode - 1

SAFEMASTER W Radio controlled safety system Wireless Functional Safety in group mode Our experience. Your safety.

Open the catalog to page 1
SAFEMASTER W group mode - 2

SAFEMASTER W – Wireless Safety in group mode ... ... with high availability for ranges up to 800 m SAFEMASTER W Safe wireless modules – reliably protect safety zones wirelessly SAFEMASTER W - Your advantages at a glance: The radio controlled safety system UH 6900 in group mode offers new options and solutions in the field of functional safety. Even in areas where classic safety technology confronts its limits: Unidirectional with indication signals Wireless safe signal transmission ensures a high level of availability, even in rough wide ranging and difficult to access plants Whether you...

Open the catalog to page 2
SAFEMASTER W group mode - 3

Basic function: safe shutdown of all group receivers ... ... shut down up to 255 group receivers with the group controller Group mode 3 safety inputs *) (local operation) 3 dual channel safety inputs Operating principle UH 6900 Group receiver The radio controlled safety system UH 6900 in group mode, transmits safety signals from the group controller to one or more group receivers. Up to three 2-channel safety sensors (such as emergency-stop, light curtain, safety gate, etc.) can be connected to the controller. After actuating one of these safety functions, the safety outputs of all group...

Open the catalog to page 3
SAFEMASTER W group mode - 4

Function expansion: Control and report ... ... bidirectional communication Group mode with feedback 3 safety inputs *) (local operation) 3 dual channel safety inputs Operating principle UH 6900 Group receiver By pairing the group controller with a group receiver using the SAFEMASTER W Manager software, additional control, indication and status information can be exchanged between these devices. Through the ability to transmit bidirectional signals, very remote receivers are also able to receive information, e.g. that the control command has been executed. 3 safety inputs *) (local...

Open the catalog to page 4
SAFEMASTER W group mode - 5

Function expansion: Group shutdown by every participant ... ... wireless and from any location Group mode with reaction coupling 3 safety inputs *) (local operation) 3 dual channel safety inputs Operating principle The group mode setting with reaction coupling provides a facility for the group shutdown. If the safety function of a group receiver is activated,the local safety output switches off and the output contacts of all the other group subscribers are not safety-oriented shut down. 1 safety output 3 safety inputs *) (local operation) This function expansion can be optionally activated...

Open the catalog to page 5
SAFEMASTER W group mode - 6

... complete protection for mobile systems and plants Practical application The radio controlled safety system UH 6900 makes best use of its inherent advantages in wide ranging and mobile systems where wiring is not possible, e.g. in logistics with automated guided vehicles (AGV). With the group controller in the switch cabinet, all AGV’s can be safety switched off during an emergency stop.This guarantees safety during service or maintenance procedures and on installation. In addition, each AGV can be locally switched off during a dangerous situation.With “Group mode with reaction coupling”...

Open the catalog to page 6
SAFEMASTER W group mode - 7

Easy start up Quick start in just 3 steps 1 SAFEMASTER W Manager comprehensive diagnostics Quick and easy setting of the operating mode via a rotary switch SAFEMASTER W SAFEMASTER W Manager Manager Group mode Quick and easy set up and diagnostics for your wireless system DOLD offers a free software program “SAFEMASTER W Manager” which facilitates set up, diagnostics and system logging through a simple graphic user interface. The “Group mode with feedback or reaction coupling” function expansion can be set with the SAFEMASTER W Manager software. Select frequency channel using SAFEMASTER W...

Open the catalog to page 7
SAFEMASTER W group mode - 8

Flexible, versatile -System components Best possible safety for all industries SAFEMASTER W System overview Wireless Safety Solutions from a single source The radio controlled safety system UH 6900, expands on the comprehensive DOLD functional safety wireless product range. In addition to the existing SAFEMASTERW safe mobile emergency stop systems and wireless enabling switches, DOLD now offers a safe wireless solution for paired and group mode operation systems. It can be integrated wirelessly into a variety of safety-related applications, even in rugged, difficult to access and wide...

Open the catalog to page 8
SAFEMASTER W group mode - 9

Innovative safety concepts As a solution provider for safe automation and electrical safety, DOLD offers a comprehensive product portfolio from a single source. Our SAFEMASTER solutions have been successfully used for many decades around the world. From single function safety switching devices for simple safety applications through to multifunction, modular safety systems, DOLD develops tailor-made solutions for your industry and applications. We would be happy to provide you with information about further safety solutions. SAFEMASTER STS The SAFEMASTER STS modular safety switch and key...

Open the catalog to page 9

All DOLD catalogs and technical brochures

  1. SAFEMASTER

    13 Pages

  2. SAFEMASTER

    5 Pages

  3. VARIMETER

    7 Pages

  4. SAFEMASTER W

    9 Pages

  5. DOLD

    3 Pages

  6. News 2018.01

    3 Pages

  7. News 2017.01

    5 Pages

  8. News 2017.02

    3 Pages

  9. News 2016

    3 Pages

  10. Highlights

    7 Pages