SAFEMASTER C Multifunctional safety module UG 6970 Safety technology has never been this simple. The multifunctional safety module UG 6970 from the SAFEMASTER C family serves the protection of staff and machinery by releasing and interrupting safety circuits. Up to two independent safety functions which are selected in a simple way and without programming via latching rotary switches can be implemented in a single device.The flexible adjustment of the safety functions lead to a sustainable reduction in storage costs. Besides safety functions such as emergency stop, protective door, non-equivalent safety sensor, two-hand or light barrier, it also allows you to connect your safety-related mats and safety edges.The variable start configuration which can also be adjusted via rotary switches, allow for an optimal adjustment in accordance with the application. Besides the manual and automated start, the mutual manual start can also be selected for both safety functions. With its width of 22.5 mm, the multifunctional safety module UG 6970 supplies two N/O contacts and one semiconductor monitoring output for each safety function. In accordance with the requirements, the number of safety contacts can be multiplied via the related extension module UG 6929 or the combine extension module UG 6912.28. Your advantages at a glance Two safety functions independent from each other selectable Emergency stop Safety gate Two-hand control Safety-mat / safety edge Light barrier Antivalent safety sensor Two safety functions at the same time and a width of 22.5 mm Manual or automated start, individually or jointly

Open the catalog to page 1
Flyer Safety module UG 6970 - 2

Multifunctional safety module UG 6970 Technical features Complies with - Performance Level (PL) e and category 4 in accordance with EN ISO 13849-1: 2008 - Safety Integrity Claim Limit 3 (SIL CL) 3 according to IEC/EN 62061 - Safety Integrity Level (SIL) 3 according to IEC/EN 61508 and IEC/EN 61511 In accordance with EN 50156-1 for furnace installations Line fault detection at the start button Activation via start button or automatic start, joint start possible With or without cross fault detection 2-channel design Forcibly guided output contacts Output: 2 contacts per safety function 1...

Open the catalog to page 2

All DOLD catalogs and technical brochures

  1. SAFEMASTER

    13 Pages

  2. SAFEMASTER

    5 Pages

  3. VARIMETER

    7 Pages

  4. SAFEMASTER W

    9 Pages

  5. DOLD

    3 Pages

  6. News 2018.01

    3 Pages

  7. News 2017.01

    5 Pages

  8. News 2017.02

    3 Pages

  9. News 2016

    3 Pages

  10. Highlights

    7 Pages