Catalog excerpts
VARIMETER RCM Residual current monitor IR 5882 Reliable detection of fault currents Our compact residual current monitor IR 5882 of the VARIMETER RCM family of DOLD measures AC fault currents and pulsating DC fault currents. The device signals them via its potential-free change over contacts dependent on the adjusted respond values for prealarm and alarm. The IR 5882 is also suitable for the use in consumer units and industrial panels due to the integrated residual current transformer and a depth of only 63 mm. Residual current monitors are measuring and monitoring residual- and fault currents in grounded voltage systems. They will be used in plants where they should signal a failure but not disconnect. Compared to current protection switches that are switching-off immediately at certain measuring fault currents, residual current monitors are showing a fault current early and are signaling an insulation degradation for an output contact for example. Due to the early detection of insulation faults as well as preventive maintenance and service outside the operating time, unexpected stand stills of machines and plants can be avoided and do not result to inadvertent operating interruptions, damages or high costs. Your advantages Integrated residual current transformer (diameter 28 mm) Time- and cost optimal service / maintenance Preventive fire- and plant protection by early fault signal Simple adjustment via snapping rotary switches Wire break detection in measuring circuit Wide auxiliary voltage range AC/DC24 - 230V
Open the catalog to page 1Residual current monitor IR 5882 Technical features According to IEC /EN 62 020 For AC currents and pulsating DC currents, Type A according to IEC/TR 60755 Frequency range 20 ... 2000 Hz Storing of alarm value is selectable With prewarning With proof- and delete button Wire break detection in measuring circuit Short reaction time Width of 105 mm with integrated residual current monitor With adjustable response delay tv Closed- circuit current principle (output relay not activated in case of a fault) LED- display for auxiliary voltages, prewarning and alarm Order information Standard type:...
Open the catalog to page 2All DOLD catalogs and technical brochures
-
Safety technique
626 Pages
-
SAFEMASTER
13 Pages
-
SAFEMASTER
5 Pages
-
SAFEMASTER PRO
9 Pages
-
VARIMETER PRO
5 Pages
-
VARIMETER
7 Pages
-
SAFEMASTER W group mode
9 Pages
-
SAFEMASTER W
9 Pages
-
PCB Relays Safety Relays
148 Pages
-
DOLD
3 Pages
-
Insulation monitor RN 5897
2 Pages
-
Safety technique
626 Pages
-
Installation technique
114 Pages
-
Time control technique
194 Pages
-
Control technique
162 Pages
-
Power electronics
210 Pages
-
Monitoring technique
514 Pages
-
News E-Mobility
3 Pages
-
News 2018.01
3 Pages
-
News 2017.01
5 Pages
-
News 2017.02
3 Pages
-
News 2016
3 Pages
-
Highlights
7 Pages
-
Speed monitor UH 6932
2 Pages
-
Flyer Option module
4 Pages
-
Flyer Safety timer UG 6960
2 Pages
-
Flyer Safety module UG 6970
2 Pages
-
Flyer enclosure KS 4460
3 Pages
-
Brochure SAFEMASTER STS
20 Pages
-
Flyer SAFEMASTER STS
2 Pages
-
Enclosure overview
20 Pages
-
Flyer In Rail Bus
4 Pages
-
company presentation
7 Pages
-
Flyer SAFEMASTER PRO
2 Pages
-
Catalog relay modules
909 Pages
-
Catalog PCB relays safety relays
135 Pages