Overview: The document provides comprehensive information on Doepke's range of residual current circuit-breakers (RCCBs) and related devices. It includes specifications, selection guidelines, and compliance standards for various models.
Contact Information: Contact details for key personnel at Doepke, including management and sales, are provided.
Product Categories: Products are categorized into RCCBs, RCCBs with overcurrent protection (RCBO), circuit-breakers with residual current devices (CBR), modular residual current protective devices (MRCD), and residual current monitors (RCM).
Specifications and Features: Each product type is detailed with features like sensitivity to pulsating currents, AC-DC sensitivity, and application suitability for electromobility, audio systems, and industrial use.
Standards and Compliance: The document outlines standards such as VDE and DGUV for Type B RCCBs, ensuring safety and compliance in electrical installations.
Fire Protection Information: Discusses fire protection in electrical installations and RCCBs that meet these requirements, including handling frequencies above 20 kHz.
HD Series and Neutral on Right: Highlights HD versions of DFS devices, resistant to environmental conditions, and options for devices with a neutral terminal on the right.
Ordering Information: Instructions for ordering specific variants, such as HD devices or those with neutral on the right, are included.
Overview of Model Ranges:
  • SK Model Range: Conforms to Standard E DIN VDE 0664-100, for installations where fire protection is not mandatory.
  • B+ Model Range: Based on VDE 0664-400 Standard, provides fire protection up to 20 kHz.
  • NK Model Range: Offers fire protection from 300 mA at frequencies up to 100 kHz, ideal for high-frequency installations.
Guidelines for RCCB Selection:
  • Considerations include installation type, fire hazards, and AC-DC sensitivity.
  • Models are available for various applications, including harsh environments and industrial uses.
Technical Specifications:
  • Devices are available in 2-pole and 4-pole designs, with rated residual currents from 0.01 A to 0.50 A.
  • Accessories include auxiliary switches, restart locking facilities, and automatic reclosing devices.
Applications:
  • Suitable for systems with frequency converters, such as pumping, air conditioning, and medical devices.
  • Applicable in environments with potential fire hazards, including agriculture, biogas systems, and paint shops.
General Overview: The document outlines general conditions for the supply of products and services in the electrical industry, covering delivery, risk transfer, assembly, defects, and legal considerations.
Delivery and Storage Costs: Storage costs may be charged if goods are not accepted within a month after notification of readiness for dispatch.
Passing of Risk: Risk transfers to the purchaser upon shipment or pickup by the carrier, or upon completion if assembly is included.
Assembly and Erection: The purchaser is responsible for providing necessary infrastructure for assembly, with additional costs for delays not caused by the supplier.
Receiving Supplies: Supplies cannot be refused due to minor defects.
Defects as to Quality: The supplier is liable for defects existing at the time of risk transfer, with a 12-month limitation for claims.
Industrial Property Rights and Copyrights: The supplier ensures supplies are free from third-party IPR infringements in the delivery country.
Conditional Performance: Contract performance is subject to compliance with trade laws and sanctions.
Impossibility of Performance: Purchasers can claim damages for non-performance unless the supplier is not responsible.
Other Claims for Damages: Purchasers have limited claims for damages unless based on specific legal grounds.
Venue and Applicable Law: Disputes are settled at the supplier's business location, governed by German law.
Severability Clause: Invalid provisions do not affect the validity of the remaining contract.
Software Clause: Addresses breaches or performance issues related to standard software provided with hardware.
See more

Catalog excerpts

Product Information 1/2019-1

Product Information 1/2019 ––– Residual current circuit-breakers ––– RCCBs with overcurrent protection ––– Circuit-Breakers with residual current trip ––– Modular residual current devices ––– Residual current monitors ––– Miniature circuit-breakers ––– Load disconnectors, installation relays, pulse relays –

 Open the catalog to page 1
Product Information 1/2019-4

Contents Page » Your contact partners here at Doepke 6 » Comparison of AC-DC sensitive residual current circuit-breakers 8 » Informations concerning fire protection/HD series/Neutral on right 8 » Guidelines for the selection of residual current circuit-breakers 9 Residual current circuit-breakers (RCCB) » Typ A » Typ A HD » Typ A S » Typ A KV » Typ A EV » Typ A FT » Typ A V » Typ A W » Typ A Twin » Typ A KV Twin » Typ A S Twin » Typ A NA » Typ A ST/STR » Typ AC » Typ AC S » Typ AC FT » Typ AC W » Typ F » Typ F EV » Typ FEV HD » Typ F Audio » Typ B SK » Typ B SK MI » Typ B SK S »...

 Open the catalog to page 4
Product Information 1/2019-6

Anne Hänfler Tanja Heidemann Head Office Head Office Nicole Sikken Birgit Esen Edgar Eichmann Head of Domestic Sales Assistant of Sales Management Head of Export Sales Gerhard Janssen Sarah Wolthoff Lisa Jonas Regional Export Manager Sales Department Sales Department Denise Janssen Elke Blonn Stefan Davids Sales Department Sales Department Head of Sales Promotion Stefan Ahrling Hans-Wolfgang Sorg Holger Meier Sales Promotion West Sales Promotion South/ Switzerland Sales Promotion East Sales Promotion Andreas Müller Secretary/Head Office Your contact partners here at Doepke Florian Schmitt Ralf...

 Open the catalog to page 6
Product Information 1/2019-7

Doepke Product Management Marcus Häbel Jochen Janßen Technical Support Product Management Johann Meints Tanja Schüler Elke Bents-de Groot Marketing Service Marketing Service Catrin Frieden Sylvia Barkhoff Media Designer Media Designer Katharina Silo Gerd Ewen Marketing communication Head of Business Administration Marketing Service Heino Thoben-Mescher Product Management Product Management Service Product Management Holger Freese Team Leader Product Management Kerstin Debelts Melanie Brandes Quality Management Jutta Bork Insa Quaschny Stock Accounting Shipping Department Shipping Department Stock...

 Open the catalog to page 7
Product Information 1/2019-8

Comparison of AC-DC sensitive residual current circuit-breakers Many standards, regulations and directives demand the provision of a Type B AC-DC sensitive residual current ciruit-breaker (RCCB). Wherever threephase electronic equipment is connected to mains without electrical isolation, AC-DC sensitive residual current circuit-breakers must be employed. There are, however, also cases in the 230 V mains net where they are applicable, e. g. photovoltaic (solar energy) installations with inverters lacking a transformer. Pumping stations, air conditioning and ventilation facilities, escalators,...

 Open the catalog to page 8
Product Information 1/2019-9

Doepke Guidelines for the selection of RCCBs in relation to fire protection criteria A DFS 2/4 A Conventional type A residual current circuit-breakers that are sensitive to pulsating currents Example of single-phase frequency converters Basic circuit for electronic operating equipment in accordance with DIN VDE 0100 530 ȃ AC full bridge circuit Type F residual current circuitbreakers that are mixed frequency sensitive ȃ AC star circuit ȃ Full bridge circuit between external conductors ȃ Agitators ȃ Hammer drills ȃ Single-phase detection with smoothing Systems with frequency converters: ȃ Pumping,...

 Open the catalog to page 9
Product Information 1/2019-10

mod. pack. widths units Residual current circuit-breakers DFS 2 A, 2-pole pulsating AC/DC-sensitive type A 16 A DFS 2 016-2/0,01-A IAn = 0.01 A All devices are also available in HD design (see info pages). Accessories: Auxiliary Switches DHi, Restart locking facilities WES, Clamp covers KA, Software BS DLS/DFS, Information stickers HAS, Automatic reclosing devices DFA 4 Accessories on page 68, 84, 87 EAN refers to individual item | All illustrations are non-binding.

 Open the catalog to page 10
Product Information 1/2019-11

Type A Residual current circuit-breakers (RCCB) Residual current circuit-breakers DFS 4 A, 4-pole pulsating AC/DC-sensitive type A 16 A DFS 4 016-4/0,01-A IAn = 0.01 A All devices are also available in HD design and with right-hand neutral conductor (see info pages). Accessories: Auxiliary Switches DHi, Restart locking facilities WES, Clamp covers KA, Software BS DLS/DFS, Information stickers HAS, Automatic reclosing devices DFA Doepke mod. pack. A . . kl EAN Residual current circuit-breakers DFS 4 A HD, 4-pole hiaT pulsating AC/DC-sensitive type A, for harsh environments 125 A DFS...

 Open the catalog to page 11
Product Information 1/2019-12

Type A 12 / 13 Residual current circuit-breakers (RCCB) Residual current circuit-breakers DFS 2 A S, 2-pole pulsating AC/DC-sensitive type A, selective 40 A DFS 2 040-2/0,10-A S IAn = 0.10 A All devices are also available in HD design (see info pages). Accessories: Auxiliary Switches DHi, Restart locking facilities WES, Clamp covers KA, Software BS DLS/DFS, Information stickers HAS, Automatic reclosing devices DFA Residual current circuit-breakers DFS 4 A S, 4-pole pulsating AC/DC-sensitive type A, selective 40 A DFS 4 040-4/0,10-A S IAn = 0.10 A All devices are also available...

 Open the catalog to page 12
Product Information 1/2019-13

Doepke mod. pack. A . . kl EAN Residual current circuit-breakers DFS 2 A KV, 2-pole pulsating AC/DC-sensitive type A, short-time delayed, lightning resistant 16 A DFS 2 016-2/0,03-A KV IAn = 0.03 A increased surge current strength up to 3 kA, non-response lag time 10 ms. All devices are also available in HD design (see info pages). Accessories: Auxiliary Switches DHi, Restart locking facilities WES, Clamp covers KA, Software BS DLS/DFS, Information stickers HAS, Automatic reclosing devices DFA

 Open the catalog to page 13
Product Information 1/2019-14

mod. pack. widths units Residual current circuit-breakers DFS 4 A KV, 4-pole pulsating AC/DC-sensitive type A, short-time delayed, lightning resistant 16 A DFS 4 016-4/0,03-A KV IAn = 0.03 A Increased surge current strength up to 3 kA, non-response lag time 10 ms. All devices are also available in HD design and with right-hand neutral conductor (see info pages). Accessories: Auxiliary Switches DHi, Restart locking facilities WES, Clamp covers KA, Software BS DLS/DFS, Information stickers HAS, Automatic reclosing devices DFA 4 Accessories on page 68, 84, 87 EAN refers to individual...

 Open the catalog to page 14

All Doepke Schaltgeräte GmbH catalogs and technical brochures

  1. SIDI 1

    3  Pages

  2. DFA 2-4

    3  Pages

  3. DFA 2-2

    3  Pages

  4. DFA 2-1

    3  Pages

  5. DLS 6h B06-1

    4  Pages

  6. DRCA 1 CT 140

    2  Pages

  7. DRCA 1 CT 105

    2  Pages

  8. DRCA 1 CT 070

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.