DLS 6h B06-1
4Pages

{{requestButtons}}

Catalog excerpts

DLS 6h B06-1 - 1

Doepke The experts in residual current protection technology DATA SHEET DLS 6h B06-1 for commercial sector applications, B characteristic, 6 kA Article No. 09914019 Symbolic image 6TV Function An important stipulation of DIN VDE 0100 is to protect cables, lines and installation devices from overload and short-circuits. This requirement can be met using miniature circuit-breakers (MCBs). In industrial installations and also in commercial buildings, they often take on additional protection of equipment and devices where there are usually higher requirements than when used in residential buildings. Miniature circuit-breakers utilise both the magnetic and heat eect of the electrical current. If the current jumps to a value that is too high when a short-circuit occurs, the MCB interrupts the circuit using the magnetic eld of an energised coil. The heat that develops when there is continuous overload causes the bimetal to warp, which trips the breaker. The miniature circuit-breaker series DLS 6 has a wide selection of dierent types for a number of application areas. In addition to switches for residential and purpose-built buildings, it also contains switches for industrial applications. The compact design provides lots of space for the wiring and the large clamping area, as well as the option of using conventional wiring rails for easy processing. The series also has a large, folding label window and a clearly labelled display for the operating status. A number of additional devices, such as undervoltage or operating current trips and auxiliary and fault indicator switches, make universal use of the miniature circuit-breakers possible. The DLS 6h design for workshops has a rated short-circuit connection and disconnection capacity of 6 kA designed for distribution board and nal circuits and a large selection of rated currents in characteristics B and C. Miniature circuit-breakers with characteristic B ensure standard protection for lighting and socket circuits. As their short-circuit trip is three to ve times the rated current, they should not be used to fuse-protect load circuits with high switch-on currents. They replace the former L or H characteristic. Features rated switching capacity for use in residential buildings, screw terminals with strain-relief clamps with wide terminal cross-section range for rail and line wiring on both connection sides, designs with one, two and three poles, 1+N, 3+N, stacked rated current series of 1 A 63 A, special quick fastening for removal of multiple miniature circuit-breakers from the bottom or top interconnection, large, folding label window for a secure hold and protection of the label, use of conventional wiring rails, ON/OFF switch position indicator on the switch toggle, accessories retro-ttable on the right, labelling software free of charge Mounting quick fastening to mounting rail, any installation position Applications suitable for use in power supplies for residential and purpose-built buildings or buildings for commercial use Accessories Labelling software for DLS 6, DFS 2/4, DHi 3, DHi 4, DHi 5, DHi 6, DHi 8, DHi-S10, DHi-S11, DASA 24, DASA 230, DUSA 230, Label sheet DLS 6 Technical Data Series Number of poles Tripping characteristic Adjustment range of overload tripping Adjustment range of short-circuit tripping Tripping factor over frequency band Test current factor tripping electromagnetic Test current multiplier, trip, thermal Test current factor retaining electromagnetic Test current factor retaining thermal

Open the catalog to page 1
DLS 6h B06-1 - 2

Doepke The experts in residual current protection technology Technical Data Reference temperature thermal release Reference temperature thermal release (Variance) Isolation class Operating voltage (AC) Operating frequency Description Specification Rated voltage (AC) Rated voltage (DC) Rated current (AC) rated current range In Rated short-circuit current max. total rated switching capacity Current heat loss per current path Back-up fuse short-circuit Back-up fuse type Back-up fuse (textual) Description Protection against direct contact Max number of wires per terminal Cross section solid...

Open the catalog to page 2
DLS 6h B06-1 - 3

The experts in residual current protection technology

Open the catalog to page 3
DLS 6h B06-1 - 4

Doepke The experts in residual current protection technology Bemessungsstrom In (%) rated current In (%) Umgebungstemperatur (°C) ambient temperature (°C) Auslösecharakteristik B, C, D tripping characteristic B, C, D Auslösecharakteristik K, Z tripping characteristic K, Z

Open the catalog to page 4

All Doepke Schaltgeräte GmbH catalogs and technical brochures

  1. SIDI 1

    3 Pages

  2. DFA 2-4

    3 Pages

  3. DFA 2-2

    3 Pages

  4. DFA 2-1

    3 Pages