DFS 2 016-2/0,10-A FT
4Pages

{{requestButtons}}

Catalog excerpts

DFS 2 016-2/0,10-A FT - 1

Doepke The experts in residual current protection technology DATA SHEET DFS 2 016-2/0,10-A FT pulsating AC/DC-sensitive type A, with remote-tripping function Article No. 09115621 Symbolic image 1AT Function Residual current circuit-breakers (RCCBs) are components for implementing protective measure "Automatic switch-o of power supply" as per VDE 0100 part 410 or corresponding international installation regulations. Series DFS 2 devices are compact two-pole residual current circuit-breakers for single-phase networks. In the standard design, they only take up two module width units of space. In spite of the compact dimensions, a number of dierent tripping currents and characteristics are available at rated currents, depending on the design, up to 125 A. Usually the neutral conductor connection is located on the left side, but can be on the right if desired. Furthermore, all devices are available in the "HD" design, which is especially suitable for use in extreme environments (tunnels, swimming pools, etc.) They also have large two-tier terminals for large conductor cross-sections, a practical multifunctional switch toggle and can be provided with pre-prepared labels using free-of-charge software. Switches with residual current characteristic A are independent of the mains voltage and allow the detection of sinusoidal AC currents and pulsating DC residual currents. With the FT design the connections of the internal test key are wired to two terminals in order to be able to activate the test device externally. An auxiliary contact also reports the switch-o of the safety switch. Features integrated auxiliary switch function, contact data same as for DHi, The technical properties of the basic switch are not changed by the FT option., tripping not dependent on mains and auxiliary voltage, sensitive to AC residual currents and pulsating DC residual currents (type A), compact design for all rated currents, high short-circuit resistance, double-sided two-tier terminals for large conductor crosssection and busbar, switch position indicator, viewing window for labels, multifunction switch toggle with three positions: "on", "o" and "tripped", , neutral conductor in standard design left, optionally available: N right for any four-pole device at no extra cost Mounting quick fastening to mounting rail, any installation position, supply from any direction Applications Power supplies to residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the residual current circuit-breakers of this series can be set to switch o in the event of a second fault, RCCBs from the "FT" series are especially suitable for the remote switch-o of systems and parts of systems and for being tripped by hazard alarms, amongst other devices, Not permitted for use in TN-C networks; not permitted for protecting systems in which electronic equipment may cause smooth DC residual currents or residual currents with frequencies not equal to 50 Hz. Comprehensive protection is not provided in this case. For these applications we recommend our AC/DC sensitive residual current circuit-breakers (type B or B+). Notes Do not use as emergency stop circuit!, The contacts of the external command device must be designed for a rated residual current ≥ 0.5 A and for the rated voltage of the residual current circuit-breaker. Accessories KA-DFS2, WES, Labelling software for DLS 6, DFS 2/4 Technical Data Series Number of poles Residual current type Rated current (AC) Rated residual current I∆n Short-time delayed Selective

Open the catalog to page 1
DFS 2 016-2/0,10-A FT - 2

Doepke The experts in residual current protection technology Technical Data Maximum disconnection times min. Operating voltage range of test circuit max. Operating voltage range of test circuit Neutral conductor position Operating voltage (AC) Operating frequency Rated impulse withstand voltage Description Galvanically separated Rated voltage (AC) Description Specification min. Contact opening Rated voltage (AC) Rated current (AC) Rated short-circuit current Surge current strength max. total rated switching capacity Rated insulation voltage Rated frequency Current heat loss per current path...

Open the catalog to page 2
DFS 2 016-2/0,10-A FT - 3

The experts in residual current protection technology Wiring example

Open the catalog to page 3
DFS 2 016-2/0,10-A FT - 4

Doepke The experts in residual current protection technology Bemessungsstrom In (A) rated current In (A) Umgebungstemperatur (°C) ambient temperature (°C) Baureihe DFS 2/4 series DFS 2/4

Open the catalog to page 4