DFS 2 016-2/0,01-A FT

DFS 2 016-2/0,01-A FT

DFS 2 016-2/0,01-A FT

Product catalog summary
Overview: The document is a data sheet for the DFS 2 016-2/0,01-A FT, a residual current circuit-breaker (RCCB) by Doepke, designed for pulsating AC/DC-sensitive type A with a remote-tripping function. It is intended for use in single-phase networks and offers protection by automatic switch-off of power supply.
Specifications: The RCCB is a compact two-pole device with a rated current of 16 A and a rated residual current of 0.01 A. It features high short-circuit resistance, a multifunction switch toggle, and large two-tier terminals. The device is sensitive to AC and pulsating DC residual currents and operates independently of mains voltage.
Features: Key features include an integrated auxiliary switch function, a switch position indicator, and a viewing window for labels. The device can be mounted in any position and supplied from any direction. It is suitable for use in various environments, including extreme conditions.
Applications: The RCCB is suitable for residential, commercial, and industrial facilities with TN-S, TT, and TN-C-S networks. It is not suitable for TN-C networks or systems with electronic equipment that may cause smooth DC residual currents. For such applications, type B or B+ RCCBs are recommended.
Technical Data: The device operates at a voltage range of 230 V (max. 253 V) and a frequency of 50 Hz. It has a rated impulse withstand voltage of 4 kV and a maximum disconnection time of 300 ms at 1 · IΔn. The RCCB is designed for a maximum operating altitude of 2000 m and has a mechanical endurance of at least 5000 cycles.
Mounting and Dimensions: The RCCB is mounted on a rail and has dimensions of 45 mm width, 85 mm height, and 75 mm depth. It is made of thermoplastic resin and has a protection class of IP20 (front: IP40).
Notes and Limitations: The RCCB should not be used as an emergency stop circuit. The contacts of the external command device must be rated for a residual current ≥ 0.5 A. The device is not suitable for protecting systems with electronic equipment that may cause non-50 Hz residual currents.
Accessories: Available accessories include KA-DFS2, WES, and labelling software for DLS 6, DFS 2/4.
See more

Catalog excerpts

DFS 2 016-2/0,01-A FT-1

Doepke The experts in residual current protection technology DATA SHEET DFS 2 016-2/0,01-A FT pulsating AC/DC-sensitive type A, with remote-tripping function Article No. 09112621 Symbolic image 1AT Function Residual current circuit-breakers (RCCBs) are components for implementing protective measure "Automatic switch-o of power supply" as per VDE 0100 part 410 or corresponding international installation regulations. Series DFS 2 devices are compact two-pole residual current circuit-breakers for single-phase networks. In the standard design, they only take up two module width units of space. In spite of the compact dimensions, a number of dierent tripping currents and characteristics are available at rated currents, depending on the design, up to 125 A. Usually the neutral conductor connection is located on the left side, but can be on the right if desired. Furthermore, all devices are available in the "HD" design, which is especially suitable for use in extreme environments (tunnels, swimming pools, etc.) They also have large two-tier terminals for large conductor cross-sections, a practical multifunctional switch toggle and can be provided with pre-prepared labels using free-of-charge software. Switches with residual current characteristic A are independent of the mains voltage and allow the detection of sinusoidal AC currents and pulsating DC residual currents. With the FT design the connections of the internal test key are wired to two terminals in order to be able to activate the test device externally. An auxiliary contact also reports the switch-o of the safety switch. Features integrated auxiliary switch function, contact data same as for DHi, The technical properties of the basic switch are not changed by the FT option., tripping not dependent on mains and auxiliary voltage, sensitive to AC residual currents and pulsating DC residual currents (type A), compact design for all rated currents, high short-circuit resistance, double-sided two-tier terminals for large conductor crosssection and busbar, switch position indicator, viewing window for labels, multifunction switch toggle with three positions: "on", "o" and "tripped", , neutral conductor in standard design left, optionally available: N right for any four-pole device at no extra cost Mounting quick fastening to mounting rail, any installation position, supply from any direction Applications Power supplies to residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the residual current circuit-breakers of this series can be set to switch o in the event of a second fault, RCCBs from the "FT" series are especially suitable for the remote switch-o of systems and parts of systems and for being tripped by hazard alarms, amongst other devices, Not permitted for use in TN-C networks; not permitted for protecting systems in which electronic equipment may cause smooth DC residual currents or residual currents with frequencies not equal to 50 Hz. Comprehensive protection is not provided in this case. For these applications we recommend our AC/DC sensitive residual current circuit-breakers (type B or B+). Notes Do not use as emergency stop circuit!, The contacts of the external command device must be designed for a rated residual current ≥ 0.5 A and for the rated voltage of the residual current circuit-breaker. Accessories KA-DFS2, WES, Labelling software for DLS 6, DFS 2/4 Technical Data Series Number of poles Residual current type Rated current (AC) Rated residual current I∆n Short-time delayed Selective

 Open the catalog to page 1
DFS 2 016-2/0,01-A FT-2

Doepke The experts in residual current protection technology Technical Data Maximum disconnection times min. Operating voltage range of test circuit max. Operating voltage range of test circuit Neutral conductor position Operating voltage (AC) Operating frequency Rated impulse withstand voltage Description Galvanically separated Rated voltage (AC) Description Specification min. Contact opening Rated voltage (AC) Rated current (AC) Rated short-circuit current Surge current strength max. total rated switching capacity Rated insulation voltage Rated frequency Current heat loss per current path max....

 Open the catalog to page 2
DFS 2 016-2/0,01-A FT-3

The experts in residual current protection technology Wiring example

 Open the catalog to page 3
DFS 2 016-2/0,01-A FT-4

Doepke The experts in residual current protection technology Bemessungsstrom In (A) rated current In (A) Umgebungstemperatur (°C) ambient temperature (°C) Baureihe DFS 2/4 series DFS 2/4

 Open the catalog to page 4

All Doepke Schaltgeräte GmbH catalogs and technical brochures

  1. SIDI 1

    3  Pages

  2. DFA 2-4

    3  Pages

  3. DFA 2-2

    3  Pages

  4. DFA 2-1

    3  Pages

  5. DLS 6h B06-1

    4  Pages

  6. DRCA 1 CT 140

    2  Pages

  7. DRCA 1 CT 105

    2  Pages

  8. DRCA 1 CT 070

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.