DFA 2-4
3Pages

{{requestButtons}}

Catalog excerpts

DFA 2-4 - 1

Doepke The experts in residual current protection technology DATA SHEET DFA 2-4 for DFS 2/4 residual current circuit-breakers in new design Article No. 09100115 T Function Automatic reclosing devices (ARDs) or remote actuators are generally used to increase system availability. Usually ange-mounted to the side of the corresponding circuit-breaker devices, they are able to switch these devices back on or switch them o remotely. One or more relays report the status. According to device standards, ARDs must be able to lock if a system fault is detected. In this case, remote switching is not possible and manual intervention is necessary. Series DFA devices are only designed for operation on Doepke residual current circuit-breakers DFS 2 or DFS 4. To optimise costs, the remote actuators are adjusted to the devices' rated currents up to 63 A or 125 A, respectively. Depending on the design, the DFA devices are operated with dierent supply voltages, are tted with relays to report the switching or locked status and either do not carry out any switch-on attempts or perform one or three attempts. Furthermore, some DFA designs are able to connect an interface to the Dupline bus system, which can transmit control commands and status messages across long distances. The DFA devices are mounted to the RCCBs on the left. This variant is supplied power from a voltage source of 230 V AC. The number of restart attempts can be set to "1" or "3". The switch-on attempts in automatic mode are performed 15 seconds after a trip. This device can be decommissioned using a rotary switch on the housing cover so that no inadvertent remote operation, e.g. during maintenance work on the distribution board, is possible. Remote tripping through a residual current simulation is also possible. The current switch position of the protective switch ("switched on", "tripped" or "switched o") is indicated by three integrated relay switching contacts. A relay also signals the “locked” status. Features retro-ttable remote actuator for Doepke residual current circuit-breakers of series DFS 2 and DFS 4, variants for dierent power supplies, compact design, Mounting mounting by clamping to the left of the residual current circuit-breaker, quick fastening to mounting rail, any installation position Applications Remote actuators can be used anywhere where electrical installation are dicult to access or where high system availability should be achieved, such as on agricultural premises, in small wind power stations, photovoltaic installations, charging stations for electric vehicles, pump stations, sewage treatment plants and telecommunications systems. Notes According to the standard, automatic restart is only permitted in areas where only trained electricians have access. The remote actuator does not aect the function of the residual current circuit-breaker. Accessories DFA 2 - RC 030, DFA 2 - RC 100, DFA 2 - RC 300 Technical Data Series Specification drive mechanism max. Rated current main contact unit Number of switch-on attempts Remote release Dupline bus connection retro-fittable suitable for model range Mounting side Number of (n.o, n.c.,change-over) Operating voltage (AC) DFA 2-4 DFA 2-4 Motor drive 63 A 1, 3 true false DFS 2, DFS 4 left 1|0|0 230 V (195.5 V ... 264.5 V)

Open the catalog to page 1
DFA 2-4 - 2

Doepke The experts in residual current protection technology Technical Data Current consumption (AC) Operating frequency Description Type Description Rated voltage (AC) Rated voltage (DC) Rated power Bounce time of push buttons Pulse duration control input Description Specification Rated voltage (AC) Rated voltage (DC) Rated power Description Specification Rated voltage (AC) Rated current (AC) Rated frequency max. Switching time Description Clamping area Tightening torque Description Duty cycle Recovery time Operating position Ambient temperature Permissible humidity Housing type Mounting...

Open the catalog to page 2
DFA 2-4 - 3

The experts in residual current protection technology Wiring example NOncht blo:kicrt

Open the catalog to page 3

All Doepke Schaltgeräte GmbH catalogs and technical brochures

  1. SIDI 1

    3 Pages

  2. DFA 2-2

    3 Pages

  3. DFA 2-1

    3 Pages

  4. DLS 6h B06-1

    4 Pages