» Field sampling of oil and/or gas (SF6, Nitrogen, air, inerts) Simple, robust and versatile instrument/system Instantaneous results with high accuracy Eliminates harmful chemicals associated with Karl Fischer titrations Simple to use Moisture-in-Oil Probe: » Relative Saturation (RS): 0 to 100% » RS Accuracy: ±1% from 0 to 90% RS, ±2% from 90 to 100% RS » Temperature Measurement Range: -40° to +100° C » Temperature Accuracy: ±0.1° at 20° C Dewpoint Probe: » Dewpoint Measurement Range: -70° to +30° C » Dewpoint Accuracy: ±2° C full scale » Temperature Measurement: -10° to +60° C » Temperature Accuracy: ±0.2° at 20° C » Pressure range: 0 to 20 bar Handheld Indicator: » Display: LCD with backlight. English, French, Spanish, German, Japanese, Russian, Swedish, Finnish » Probe Inputs: 1 or 2 » Data Logging Capacity: 900 to 2700 data points at 1s to 12h intervals » Battery: 6V NIMH pack, 4h charge time » Operate time: 48h (continuous), up to 30 days (data logging mode) Accessories » Additional Moisture-in-Oil probe » Additional Dewpoint probe » 10m probe extension cable Doble Lemke GmbH Zschoner Ring 9, 01723 Kesselsdorf / Dresden Germany www.doble-lemke.eu Doble Lemke AG Kaiserstrasse 9, 4310 Rheinfelden Switzerland www.doble-lemke.eu