FLOW CONTROL VALVE CT 100 Service tool for control and charge nitrogen into DOA breakers accumulators Adaptor the adaptor can be separated from the tester body Ring nut of the adaptor Valve for discharging the excess of pressure Handle for opening closing the valve cap Nitrogen inlet in the tester Pressure gauge Internal allen key that open/closes the valve cap acting on the handle CT 100 tool is a service item necessary to make the service of DOA breakers, like all hydraulic breakers DOA hammers are equipped with a nitrogen accumulator that in case of failure has to be replaced and recharged with nitrogen at a preussure between 35-40 Bar. CT100 allows to open up the check valve of the accumulator, to adjust the recharging nitrogen pressure and to close the check valve. 22066 Mariano Comense (CO) - ITALY - Via Sant’Agostino 158 Tel. (+39) 031 792 040 - www.doa-srl.com - [email protected]