Catalog excerpts
Technical Office for Digital Electronics Electronic Apparatus Engineering Measuring Instruments for Environmental Protection We are building high-precision samplers for dust, gas and rain since 1970. DIGITEL DPA14 Low Volume Aerosol Sampler designed for EN12341:2014 ▪ For autonomous, continuous sampling ▪ Automatic filter changer for 30 filters ▪ Constant and precise flow ▪ Filter diameter 47 mm ▪ For PM2.5 and PM10 measurements according to EN12341:2014 ▪ TSP, PM10, PM2.5 and PM1 inlets ✓ Light weight but robust and weather proof ✓ Low energy consumption ✓ Low maintenance cost ✓ Easy programming with touchscreen ✓ Easy filter handling ✓ Software for easy EN12341 tests ✓ Wide range of options and accessori
Open the catalog to page 1Technical Office for Digital Electronics Electronic Apparatus Engineering Measuring Instruments for Environmental Protection We are building high-precision samplers for dust, gas and rain since 1970. Introduction DIGITEL Low Volume Samplers DPA14 are fully automatic systems to sample dust and aerosol particles for later assessment and analysis (gravi-metric and analytical determination) in accordance with EN12341:2014. The sampler operation range in standard execution is 5 to 50 litres per minute (0.3 to 3m³/h). The DIGITEL LVS DPA14 has a magazine of 30 filters stretched in filter holders....
Open the catalog to page 2Technical Office for Digital Electronics Electronic Apparatus Engineering Measuring Instruments for Environmental Protection We are building high-precision samplers for dust, gas and rain since 1970. ambient temperature, pressure and humidity sensor front plate main switch touch screen frequency inverter USB Port cooling body for filter magazine magazine for empty filters magazine for sampled filter flow rate sensor output interfaces temperature, pressure and humidity sensor changing mechanics cooling compressor pump compartment connection to power supply Easy programming Compact aluminium...
Open the catalog to page 3Technical Office for Digital Electronics Electronic Apparatus Engineering Measuring Instruments for Environmental Protection We are building high-precision samplers for dust, gas and rain since 1970. Technical Data Flow rate 30 round filters of d = 47 mm, flowing area d = 40 mm plus one in sampling position Time programs Work, Pause (0 to 59’999 minutes each), start time adjustable, using date and time Different sampling cycles programmable Cooling capacity of compressor Mean life cycle suction unit Constancy of sample flow Negative pressure Max. capacity 800 mbar, limited to -450 hPa for...
Open the catalog to page 4All DNOTA catalogs and technical brochures
-
DIGITEL DPA16
3 Pages
-
Thermo Scientific Model 146i
2 Pages
-
Thermo Scientific 450iQ
2 Pages
-
Thermo Scientific Model 42i
2 Pages