1. Catalogs
  2. DL Chemicals
  3. DL MAXI EGALINE

DL MAXI EGALINE
1 /2Pages

DL MAXI EGALINE

DL MAXI EGALINE
1 /2Pages

Catalog excerpts

DL MAXI EGALINE-1

TECHNICAL DATA SHEET Dry, fast-levelling, cement-bound mortar Ready-to-use Allows for smoothing unevenness from 2 mm to max. 30 mm By addition of water, a self-levelling mortar is obtained Does not contain grain An excellent self-deliquescence Fast hardening Excellent adhesion High resistance after curing For indoor floor applications: parquet, vinyl, LVT linoleum, cork, carpet, laminate, tiling. Suitable surfaces are: cement-bound screeds, rough concrete, elements in precast concrete, mortar layers, old tile floors, polished concrete. Suitable for underfloor heating. TECHNICAL CHARACTERISTICS Consistention Cement, quartz sand and high-quality additives Brown grey Mixing ratio ± 30 minutes (higher temperature shortens the open time) Processing temperature (surface & ambient) Maximum total layer thickness After 4 hours : ± 9 MPa (N/mm²) After 24 hours : ± 17 MPa (N/mm²) After 7 days : ± 25 MPa (N/mm²) After 28 days : ≥ 30 MPa (N/mm²) = class C30 After 4 hours : ± 2 MPa (N/mm²) After 24 hours : ± 4 MPa (N/mm²) After 7 days : ± 7 MPa (N/mm²) After 28 days : ± 9 MPa (N/mm²) = class F7 Residual moisture after 24 hours (5 mm): NBN EN 13813 Shelf life, in the original packing and stored in a cool place Curing time (+20°C, 65% relative humidity and +18°C foundation temperature): Walkable METHOD OF USE Preparation • The substrate must be rough, dry, dust and oil free and free of loose parts. • Non-absorbent, smooth surfaces (such as polished concrete, ceramic tiles ...) must first be degreased and sanded. • For applications on floors with underfloor heating, the residual moisture content must be ≤ 1.8% CM (Carbide Method measurement). This technical data sheet replaces all previous editions. The data on this sheet have been compiled according to the last laboratory report. Technical characteristics can be changed or adapted. We are not responsible for any incomplete information. Before use, one needs to ensure that the product is suitable for his application. Therefore, tests are necessary. Our general conditions apply. DL Chemicals nv Roterijstraat 201-203 - Zone 5 Snepbeek - 8793 Waregem - Belgium T +32 56 62 70 51 - F +32 56 60 95

 Open the catalog to page 1
DL MAXI EGALINE-2

Primer • Non-absorbent, smooth, dense surfaces (such as polished concrete, ceramic tiles ...) must first be degreased and polished/sanded, then be pretreated with DL Egaline Primer. • Prime absorbent surfaces (such as cement screeds, concrete ...) with Primer PU Turbo and then sand it in. • Prime cement screeds or concrete with a residual moisture cavity ≤ 5% CM (Carbide Method measurement) with 2 layers of Hydroblocker 2K and sand it in (for processing, see technical data sheet Hydroblocker 2K). • For floors that are subject to rising moisture, prime with Hydroblocker 3K and sand it in (for...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.