Overview: The document outlines the specifications and functionalities of various pH meters, conductivity meters, and a multi-function water quality meter. It covers measurement methods, display units, measurement ranges, calibration, and additional features.
pH Meters: Three models (HM-42X, HM-41X, HM-40X) are described, utilizing glass electrode methods for pH, platinum electrode methods for ORP, and ion electrode methods. They feature touch panel color graphic LCDs or customized LCDs. The pH range is 0.000 to 14.000, with temperature compensation from 0 to 100°C. Calibration can be performed up to 5 points using JIS, US, or customized standard solutions. Data memory ranges from 2000 to 1000 data points, and optional external printers can be connected.
Conductivity Meters: Two models (CM-42X, CM-41X) use AC 2-electrode methods for conductivity measurement. They offer auto-selection of measuring frequency (80Hz/3kHz) and have a temperature range of 0.0 to 100.0°C. The document specifies ranges for conductivity, resistivity, salinity, concentration, and TDS, with repeatability within ±0.5% FS. Temperature compensation is available from 0 to 100°C.
Multi-Function Water Quality Meter: Model MM-43X supports multiple measurement methods, including pH, ORP, ion, conductivity, and dissolved oxygen. It features a touch panel color graphic LCD and allows for simultaneous or single-channel display. The pH range is 0.000 to 14.000, and it supports various calibration methods, including auto calibration for dissolved oxygen.
Additional Features: Features include auto hold function, statistical calculation, security functions, and external input/output options like RS-232C and USB interfaces. Power sources include AC adapters and AA batteries, with power consumption details provided for each model.
Accessories and Options: Standard accessories include electrodes, standard solutions, electrode holders, and operation manuals. Optional connections for external printers and other devices are available for certain models.
Specifications:
  • Display Range: Supports multiple conductivity ranges: 0 to 2.000 mS/m, 0 to 20.00 mS/m, 0 to 200.0 mS/m, 0 to 2.000 S/m, and 0 to 20.00 S/m.
  • Display Unit Switching: Users can select between SI Units (S/m, Ω・m) and Conventional Units (S/cm, Ω・cm).
  • Repeatability: The meter's main unit has a repeatability of ±0.5% FS.
  • Range Setting: Manual adjustment is required.
  • Temperature Compensation: Manual compensation is available for a range of 0 to 60℃, with a standard temperature fixed at 25℃.
  • Output: Conductivity output is 0 to 1V FS, with a fixed temperature coefficient of 2% per ℃.
  • Frequency of Measurement: Automatically selects between 80Hz and 3kHz.
  • Operation Temperature Range: 0 to 40℃.
  • Power Source: Operates on AC Line or two Size AA batteries, with a power consumption of approximately 3 VA.
  • Main Unit Dimensions and Weight: Approximately W148×H75×D221 mm and 0.7 kg.
Standard Accessories:
  • Cell (C-50101B) - 1 piece
  • Electrode Holder - 1 piece
  • Electrode Stand - 1 piece
  • Support - 1 piece
  • Stopper - 1 piece
  • Electrode Attachment (J-type) - 1 piece
  • Polyethylene Beaker (150 mL) - 1 piece
  • Mercury Thermometer - 1 piece
  • AC Cable - 1 piece
  • Ground Wire - 1 piece
  • Former Unit Label - 1 set
  • Operation Manual - 1 copy
See more

Catalog excerpts

Xseries-1

Benchtop Water Quality Meter

 Open the catalog to page 1
Xseries-2

Large Touch Screen Large, Easy-to-read display Flat panel, easy maintenance Vertical display Horizontal display Excellent system extensibility Turntable External printer Electronic recording can be established by connecting to a PC or network (Please inquire about the PC software for Part 11)

 Open the catalog to page 2
Xseries-3

Various Display Functions Vertical/Horizontal screen switch Graphic Display Touch panel input Easy-to-read menu Maintenance information New sensors and electrodes Soft lead wire RED:pH YELLOW:ORP WHITE:Conductivity Easy distinction of electordes by different coloring RoHS compliant DO electro

 Open the catalog to page 3
Xseries-4

Xseries Line-up Touch Screen Multi-function Water Quality Meter pH/Ion Meter Including pH combined electrode Including conductivity cell Resistivity Salinity External printer Conductivity Meter External printer External printer Turntable USP645 Customized LCD Basic Type pH Meter Including pH combined electrode External printer Conductivity Meter Conductivity Resistivity Salinity Including pH combined electrode Including conductivity cell External printer Dry battery For international sales only Electrode attachmentb(J) Strong pH composite electrode GST-5841C Electrical conductivity cell 0DE00001...

 Open the catalog to page 4
Xseries-5

Electrode Holder Electrode Attachment Electrode Stand Electrode Holder/Stand

 Open the catalog to page 5
Xseries-6

Cal-Memo sensor The sensor memorizes Model, serial number, calibration data Oxalate pH Standard Solution pH 1.68 500mL Phthalate Standard Solution pH 4.01 ORP Standard Solution (Phthalate Standard Solution pH 4.01 500mL+Quinhydrone powder) Phosphate pH6.86 Standard Solution Abrasive Solution for ORP Electrode 10mL Borate Standard Solution pH 9.18 Carbonate pH Standard Solution pH 10.02 Inner Solution for Reference Electrode RE-4 50mLX3 * 1 Strong Glass electrode. The strength of its tip is improved. Hard to break. *2 Float Float is built-in whose exchange span of internal solution can be checked...

 Open the catalog to page 6
Xseries-7

Noted) DO electrode cannot be used for the below membrane type galvanic cell method. OE-270AA/570BA, 470AA/470BA Note(2) For BOD measurement, auxiliary equipment such as incubator bottle and incubator is necessary. Recommended incubator bottle JIS standard Medium Size TS19/22 (Large-diameter 18.8mm, Reduced-diameter 16.6mm, Length 22mm)

 Open the catalog to page 7
Xseries-8

Electrode Ion replacement chip Measurement range(Optimal pH range) Intereference of coexisting ion*1/ Note * 1 Interference of coexisting ion If an ion coexists in the solution, it can cause data errors when measuring the targeted ion. A selectivity coefficient of 10x means that if the solution contains a coexistent ion that is 10x times greater than the value of the targeted ion that is measured, an error occurs in which the value of the targeted ion equals the coexistant ion value. If the concentration level of the coexistent ion is high enough to affect the measured values, we recommend conducting...

 Open the catalog to page 8
Xseries-9

Specifications/Function pH meter Model Name pH :Glass electrode method Platinum electrode method ORP : Ion :Ion electrode method Temperature Thermistor resistor : Measurement Method Display unit pH :Glass electrode method Platinum electrode method ORP : Temperature: Thermistor resistor pH :Glass electrode metho Temperature: Thermistor resistor Touch panel color graphic LCD Depends on the sensor used Display Range Measurement Item/Range Display resolution switch pH Temperature Compensation Range ATC (Auto Temperature Compensating) : 0~100.0℃ MTC (Manual Temperature Compensating) : 0~100.0℃ ATC...

 Open the catalog to page 9
Xseries-10

Conductivity meter Model Name Measurement Method Conductivity: AC 2-Electrode Method Temperature: Thermistor Resistor Conductivity: AC 2-Electrode Method Temperature: Thermistor Resistor Conductivity Measuring frequency Display unit Touch panel color graphic LCD Conversion from conductivity Conversion from conductivity Conversion from conductivity Conversion from conductivity Conversion from conductivity Conductivity (Manual/Auto Range Switching) (Depending on the cell) Resistivity (Manual/Auto Range Switching) (Depending on the cell) 0.00 ~ 4.04%(NaCl) 0.00 ~ 42.40 (PSS:Sea water salinity) Measurement...

 Open the catalog to page 10
Xseries-12

Practical manually operated analog and digital models HM-20J pH Meter •Easy-to-read of measurements digital display •Capable of measuring oxidation-reduction potential (ORP) (electrode sold separately) •With mV-shift function •Low price, compact size Specifications Model Name Standard Accessories pH Electrode GST-5711C 1~Pc~ Standard Solutions Each 1 bottle Electrode Holder 1 piece Electrode Attachment 1 piece (J-type) Electrode Stand 1 piece Polyethylene Beaker 150 mL 3 pieces Power Cable 1 piece Ground Wire 1 piece Conductivity Meter Practical manually operated digital model CM-20J • Conductivity...

 Open the catalog to page 12