R-Series Including Our Latest Versatile Water Quality Meter -Switch Applications By Just Changing The Connected Sensor ! Features our high-performance "Strong" pH Electrode with "Float" indicator Records ambient conditions together with measurement data USB interface LAN interface

Open the catalog to page 1
R Series brochure. - 2

High Performance With Easy Operation The perfect Solution For Sophisticated Analyi A smart versatile water quality meter that automatically selects the measuring parameter by recognizing the connected sensor •Just connect the appropriate sensor to quickly change measurement The measurement screen automatically changes when the sensor with built-in memory is connected. Simultaneous, two channel measurement and display is also available. Automatically recognizes sensor Information Example of pH / conductivity measurement screen Example of pH / ORP measurement screen 'Flexible sensor...

Open the catalog to page 2
R Series brochure. - 3

Multi-function Water Quality Meter MM-60R Further Improvement for compliance with GLP & Validation Support Capability •Room circumstance (ambient temperature, humidity) display and recording capability temperature ^^^^^^ Humidity Attaching the optional temperature and humidity sensor to the main unit enables advanced measurement control by recording both the measurements and the room circumstance at the time of measurement. ►Calibration resume data function history recording capability • Calibration date • Sensor type • Sensor production number • (Ambient temperature* • Calibration data and...

Open the catalog to page 3
R Series brochure. - 4

Enhanced Operability •Flip cover allows access to detailed functions Close for single key operation •Handy remote key operation Adding the optional, drip-proof remote switch enables : Further improving measurement •Useful HELP function Context sensitive "Help" function available to assit user (For example to show manipulation guide when calibration error has occurred)

Open the catalog to page 4
R Series brochure. - 5

Advanced Functionality UlSB (host) standard equipment Large capacity memory for storing measurement data. Importing data into your PC becomes more easier: Data can be saved to USB memory and imported into your PC in CSV format using the R-LOG software. #Network interface (LAN connectivity standard equipment) Dedicated R-LOG software enables data ^Enhanced security function (Models:HM3OR,CM3OR, MM6OR> Users are restricted by employing passwords. This equipment also enables restrictions on data access by setting unit. • Enhanced printing fUnCtiOn (The HM-25R and CM-25R models are not capable...

Open the catalog to page 5
R Series brochure. - 6

A^omplete range;of jnstrumentpre available from basic modeis through to advzmce^ultMunctioffmodels Standard type 0.01/0.001 pH conversion display possible C/W pH Electrode GST-5741 C as standard accessories •Large-size color graphic, LCD display •Data memory (300 data items) •0.01/0.001 pH conversion display possible •Laboratory circumstance (Ambient temperature, humidity) measurements, recordable (Option) •USB (Host) and LAN compatibility are provided as standard •Capable of connecting to RS-232C/External printer •Capable of automated measurement (Connects to turntable) (Measurement...

Open the catalog to page 6
R Series brochure. - 7

land humidity! Standard type Pure water temperature compensation function C/W EC cell CT-57101 B as standard accessories •Large color graphic LCD display •Data memory (300 data items) •Laboratory circumstance (ambient temperature, humidity) measurement and recording capability (Option) •USB (Host) and LAN are provided as standard •Capable of connecting to RS-232C external printer •Capable of automated measurement (Connects to turntable) (Measurement function/ range) Simplified, affordable model C/W EC cell CT-57101B as standard accessories •Large-size, easy-to-read custom LCD display •Data...

Open the catalog to page 7
R Series brochure. - 8

Multi-sample Measuring System Brings Effectiveness At Your Laboratory By Connecting To Turn-table Unit (TTT-510), R-sereis Meter Becomes Capable For Automated Multi-sample Measurement R-series Connection Examples •Automated measurement of up to 100 samples possible. There are four kinds of turn-table (12, 18, 36 & 60 damples) available. 100 samples type turn-table is also available by •Chemical resistant cleaning reservoir and various electrode cleaning methods enable wide application for many kinds of sample measurement. It can cope with various sample measurement by chemical solution...

Open the catalog to page 8
R Series brochure. - 9

Enhanced Peripheral Tool Options For Advanced Analytical Control Automated continuous multiple sample measurement capability Multiple sample measurement is possible depending *100 sample model is a special version. Turn table plate is fixed at 100 samples and can not be exchanged for other plates * Beakers and stirring bars are sold separately. Standard Accessories Table (Designated tor 12,18, 36, and 60 samples) X1 Electrode holder (Designated samples / use) X1 Pure water tank (10 L, with float switch) X1 Waste water tank (10 L, with float switch) X1 Pure water tube X1 *The attachment...

Open the catalog to page 9
R Series brochure. - 10

For controlling the measurement environment (ambient temperature, humidity) Temperature and humidity sensor When requiring higher control for measurement, it is possible to take environmental data such as the room temperature and humidity at the time of the measurement and record it with the measurement result. Additional one-key device Remote switch Can be utilized as auto hold, data memory, and print key. For plain paper printing External printer (with connecting cable) A compact size with a chart Data can be saved for long Connecting cable for external printer Printer paper (20 rolls)...

Open the catalog to page 10
R Series brochure. - 11

For simple pH adjustment control 100VAC is turned ON or OFF if the measured value exceeds the upper or lower limit when it is connected to alarm terminal of pH meter. pH controlling can be done if 100VAC reagent pump is connected with the control box using the Analog cable. *The MM-60R can be used only with 1 channel. For periodic device checks pH checker Conductivity check plug Temperature check plug Single function electrode adapter Other main unit options and accessories Product name Electrode Stand (with support and stopper) Electrode holder Parts for electrodes and standard solutions...

Open the catalog to page 11

All DKK-TOA CORPORATION catalogs and technical brochures

  1. Xseries

    12 Pages

  2. HC-G65

    1 Pages

  3. MM-42DP

    8 Pages

  4. ICA-7000

    8 Pages

  5. BPM-2000

    8 Pages

  6. MWB4-70

    8 Pages

  7. CGP-31

    2 Pages

  8. x-series

    12 Pages

  9. SWBM-161

    8 Pages

  10. WQC-30

    4 Pages

  11. IA-300

    2 Pages