MWB4-70
8Pages

{{requestButtons}}

Catalog excerpts

MWB4-70 - 1

SPECIFICATION SHEET Compact City-Water Analyzer TO/pOI«MWB4-70 This analyzer is for continuous monitoring water quality (Maximum seven parameters) at faucet feed line or water receiving tank of a building. In addition to the three items of turbidity, color, and residual chlorine, which are specified by law to be inspected daily, this analyzer can optionally conduct measurements of the electric conductivity, pH, water temperature, and water pressure. The compact B4-size allows the MWB4-70 to be installed in narrow spaces. The MWB4-70 also delivers high reliability, durability, and excellent maintainability. Features • Safe design-Easy to read and operate 1) The real-time readouts of the items measured appear on the large color display on the front panel. Along with readouts, the display also provides trend indication. This convenient feature makes it possible to analyze the cause of abnormality by referring the anteroposterior trends. 2) The operating part consists of an easy-to-read interactive touch panel. 3) The electrical part and analyzer are kept separate. This ensures the electronics remain insulated while protecting users from potential electric shock. • High reliability 1) This analyzer features a unique debubbling method that effectively minimizes the formation of bubbles in turbidity and color measurements. In the event bubbles accidentally mingle, they can be completely removed by backwashing. These capabilities enable the analyzer to improve stablity of turbidity and color measurement remarkably. 2) Time-proven non-contact swing rotary type electrode is adopted for chlorine electrode. It enables stable measurement for long period in the combination with unique ceramic beads cleaning even sample flow is fluctuated. 3) This analyzer comes with an electronic dehumidifier designed to keep dew condensation from forming inside the unit. Eliminating dew condensation not only prevents rust from accumulating inside, but also enhances the durability of the equipment. • Wide variety of output options In addition to DC 4-20 mA analog output, this device is also standardly equipped with two digital communication interfaces, RS232C and RS485. These two interfaces support the remote monitoring system. • Enhanced maintenance and operational performance 1) Operations (such as cleaning and zero calibration) can be remotely controlled from the host system is possible via the use of contact signals or the digital signal interfaces RS232C or RS485. The effective remote control of operations can help cut down on labor and costs. 2) One minute values are stored in the internal memory in 3-month intervals, and one hour values are stored in 1-year intervals. A memory card (optional) can also be inserted in the factory-supplied slot, making it possible to store and carry the data without the need for a computer. 3) The self-diagnostic feature provides advance notice about the current condition of the system, helping to make maintenance more efficient. It issues two different signals, “Caution” and “Warning”, thereby enabling users to identify the severity of the problem.

Open the catalog to page 1
MWB4-70 - 2

Measurement items and performance *DMOS: Double-diffused metal-oxide semiconductor. Standard Specifications Communication system Product name Model Objects measured Measurement range switching Display Temperature compensation range Response time Operating power Power consumption Transmission output Load resistance Contact switching output signals Contact switching input signals Compact City Water Analyzer MWB4-70 Three basic items (turbidity, color, and residual chlorine), electric conductivity, pH, temperature, and pressure : Ability to switch between two ranges for both turbidity and...

Open the catalog to page 2
MWB4-70 - 3

Construction : Indoor installation (IP43 equivalent) Case material : Aluminum Color : Light gray (Munsell 5PB 8/1 equivalent) Automatic calibration : Zero calibration for turbidity, color, and residual chlorine. The internal timer and an external contact signal are used to start calibration. (Zero water is prepared by filtering sample water through a zero water filter.) Calibration cycle setting; 0 to 24 hours (freely specified) Calibration time; Approx. 13 min. (fixed) Transmission output hold time during calibration; Calibration time approx. 13 min. + 9 min. (fixed) Automatic cleaning :...

Open the catalog to page 3
MWB4-70 - 4

Flow sheet Input/Output Signal Table X Detectors for specified measurement items can be added (Maximum seven items). Core wire (line color)

Open the catalog to page 4
MWB4-70 - 5

If you press word or numeric displayed on the left screen, the Touch panel and control screen screen will be switched over or the selected task will be executed. "Alarm" is displayed. (Press here to display the alarm list.) Entry displayed Measurement values Mode Clock Alarm Serial No. Go to Trend Ground terminal D-type grounding Power connector Vent tube ø6 (supplied) 320 260 Four M8 size mounting screws Installation Diagram Maintenance clearance 500 or more Measurement values (Press a value to view the individual setting details.) Description Displays the real-time measurements for each...

Open the catalog to page 5
MWB4-70 - 6

Standard accessories list Spare parts list Product name Special accessories • Piping parts (construction materials, sold separately)

Open the catalog to page 6
MWB4-70 - 7

Indoor self-standing frame Sample water supply valve Sample water inlet Drain outlet Dew condensate water outlet Sample water stop valve By-pass valve Frame 300±1 (40) Anchor bolt position Calibration solution supply valve 420±1 Anchor bolt position Power supply cable Calibration solution inlet Condensate outlet Product code MWB470-1A B 0 1 2 0 1 0 1 0 1 2 A Y A B C D 0 1 2 Custom spec. code; Numeric digit: 9 Alphabet: Z Measurement items  Three basic items: Turbidity, color, and residual chlorine  In addition to these items, other items can also be measured. Measurement items: EC added...

Open the catalog to page 7
MWB4-70 - 8

Manufacturing specifications for standard outdoor cubicle This is our standard compact outdoor cubicle used to house the MWB4-70. It can also be used to house communication equipment. Construction Piping end : connection Weight : Wetted part materials : Ambient conditions : Equipped devices : : IP23D, rainproof for outdoor use (sun shade included) Front door (doorstop included) Materials : SS400 (steel), SPCC (sheet steel) Board thickness : L40 x t5 (SS400), t2.3 (SPCC) Surface finish : Metallic silver, semi-gloss Acrylic paint baked-on finish (cubicle), polyurethane paint baked-on finish...

Open the catalog to page 8

All DKK-TOA CORPORATION catalogs and technical brochures

  1. Xseries

    12 Pages

  2. HC-G65

    1 Pages

  3. MM-42DP

    8 Pages

  4. ICA-7000

    8 Pages

  5. BPM-2000

    8 Pages

  6. CGP-31

    2 Pages

  7. x-series

    12 Pages

  8. SWBM-161

    8 Pages

  9. WQC-30

    4 Pages

  10. IA-300

    2 Pages