HBM-100A Panel Type pH Analyzer/Controller
4Pages

{{requestButtons}}

Catalog excerpts

HBM-100A Panel Type pH Analyzer/Controller - 1

Panel Type pH Analyzer/Controller Panel Type ORP Analyzer/Controller Compact DIN size (96 x 96 mm) panel mount pH/ORP controllers. 2-point alarm contact output and 4~20mA DC transmission output are equipped as standard. The controller is equipped with an automatic, single-action stability judgment function, which allows for accurate calibration using standard solutions and helps to eliminate operator errors. During calibration, the controller determines the status of the electrode by monitoring its characteristics and displays diagnostic information in the form of messages. Output (measurement) range that can be freely set. Measurement and display of sample temperature (0~100ºC). When the controller enters maintenance (ST-BY) mode, the previous output value is held and the alarm output is disabled. This helps to prevent disruptions to the control system, such as chemical feeds. The controller automatically switches back to measurement mode if it is left in maintenance (ST-BY) mode for more than two hours. Crack detection function for pH electrode. Temperature compensation for sample pH value and pH/ORP value shift functions. Standard Specifications Product name Model Measurement range Panel type pH analyzer/controller Panel type ORP analyzer/controller HBM-100A HBM-102A mV: -600 ~ +600 mV pH: -1.00 ~ 15.00 mV: -2000 ~ +2000 mV Temp: 0 ~ 100ºC Temp: 0 ~ 100ºC Display only. No output-signal. Display only. No output-signal. Transmission output signal 4~20 mA DC, isolated. Max. resistance: 650Ω or less. Transmission output range Adjustable (0.1 pH steps). Minimum width of 2 pH. Adjustable (10 mV steps).Minimum width of 400 mV. Control (alarm) contact 2 contacts (upper and lower limits can be set freely) a-contacts Contact capacity: 250V AC, 3A or less (resistive load) output Control sensitivity: Set to a value between 0.01~2.00pH Control sensitivity: Set to a value between 1~200mV Linearity: ±0.03pH or less (using equivalent input) Linearity: ±3mV or less (using equivalent input) Performance Repeatability: ±0.02pH or less (using equivalent input) Repeatability: ±3mV or less (using equivalent input) Response: 5 sec. or less for 90% response in FA (fast) mode, 50 sec. or less for 90% response in SL (slow) mode. Power requirements/Power consumption 90~264V AC, 50/60Hz approx. 5VA Ambient conditions -10~50ºC, 0~90% RH (when in transport and storage: -30~70ºC, 0~99% RH) Dimensions/Weight 96 (W) x 96 (H) x 90 (D) mm (panel cut-out 92 x 92 mm), approx. 0.5kg Cleaning signal input: The controller can receive a “cleaning” signal from the chemical and brush cleaners to hold output during the cleaning process. Temperature compensation for sample pH value: Coefficient setting range…±0.100/ºC Standard conversion temperature…25ºC Other functions Manual temperature compensation for glass electrode: Manual temperature compensation is carried out by specifying the sample water temperature. pH/ORP value shift: Measured value can be shifted within the range of ±1.00 pH/±100 mV. (Temperature shift range: ±5ºC) Burnout: Output signal can be shifted to the upper or lower limit when there is an abnormality, such as a cracked glass membrane or temperature sensor failure. Alarm contact output: 2 extra contacts (a-contacts, upper/lower limits can be set freely, no bandwidth limit) (4 contacts in total) Optional features Cleaner control output: The internal timer delivers 100V AC power to the chemical cleaner, brush cleaner, and other cleaners. RS-232 output: A digital communication cable can be used to send the measured pH/ORP and temperature values to a computer. Configuration Detector Electrode lead Junction box FC-4 Cleaning signal To cleaner power supply (100V AC), option Alarm contact output Power supply

Open the catalog to page 1
HBM-100A Panel Type pH Analyzer/Controller - 2

Mounting panel Panel cut-out dimensions I/O terminal block Terminal cover Panel frame Operation panel Fixing bracket Front panel/Terminal connections ST-BY display Alarm contact output terminals RANGE display WAIT display Temperature display OUT display ALARM display Sub-display ALARM key Reference electrode Temperature compensation elements Reference electrode Temperature compensation elements Shielding/ Liquid grounding Shielding/ Liquid grounding Power input terminal Power cable (100V AC etc.) Transmission output terminals Connected to receiver via transmission cable "During Cleaning"...

Open the catalog to page 2
HBM-100A Panel Type pH Analyzer/Controller - 3

Product code *1 (*2)The controller operates on adjustable-voltage 90-264V AC power supply and comes with a power output for a cleaner. Note that the same voltage supplied to the main unit of the controller is also passed through to the cleaner. Make sure the voltages are compatible. Ex. 1 Power HBM-100A source 200V AC Power source 200V AC Step-down transformer *2. The controller can be used together with “E” series cleaners, such as JHC-7E, BHC-7E, and RHC-7EC. Make sure to select 2 (“Provide”) when using the controller with the “E” series. comes with a power output for a cleaner. Note that...

Open the catalog to page 3
HBM-100A Panel Type pH Analyzer/Controller - 4

Applicable detectors A wide variety of detectors can be used together with the HBM-100A/102A controller, as shown in the following table. Select the detector that best fits the immersion type, flow-through type, and measurement conditions. For detailed specifications, see the attached detector specification sheet. Wetted part material High temperature, chemical resistant HC-703F Pressurized type (below 60˚C) Immersion type General use (below 60˚C) KCl supply type Integrated model KCl supply type Replaceable-tip electrode Process control / effluent treatment High temperature (below 80˚C)...

Open the catalog to page 4

All DKK-TOA CORPORATION catalogs and technical brochures

  1. Xseries

    12 Pages

  2. HC-G65

    1 Pages

  3. MM-42DP

    8 Pages

  4. ICA-7000

    8 Pages

  5. BPM-2000

    8 Pages

  6. MWB4-70

    8 Pages

  7. CGP-31

    2 Pages

  8. x-series

    12 Pages

  9. SWBM-161

    8 Pages

  10. WQC-30

    4 Pages

  11. IA-300

    2 Pages