M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer - 1

M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer 5nC/bar nom. A smaller pressure transducer, doubling acoustic bandwidth, but at expense of 14dB reduction in sensitivity, thus 0.01pC noise equivalent acoustic signal threshold increases to 82dB (2.5mbar) M/02 application areas include air blast measurement, combustion gas acoustic measurement, fluid flow dynamics. Signals may be superimposed upon high static pressure backgrounds. Transducers are calibrated at ambient pressure. Options STABILITY Piezoceramics are subject to a logarithmic sensitivity decay vs. time. Exposure of piezoceramics to initial high pressure, temperature produces an initial sensitivity loss. Thereafter, subject to these initial conditions not being subsequently exceeded stability is exceedingly high, of the order 1 or 2%/1st yr. Transducers subject to high pressure/temperature should be thermally and load cycled to in build minimal long term degradation. charge vs. pressure up to 200bar wideband temperature calibration -50/+300°C proof pressure test of transducers, transducer/cable assemblies to 150bar hermetic Microdot, TNC & 7/16 UNS 2 pole connectors integral hardline cable termination case isolated signal for cmr Intrinsic Version EEx ia II BT2 (Tamb.=300°C), ENVIRONMENTAL M/02s have a variety of signal outlet options to cater for more extreme operating conditions. These encompass fluid immersion of transducer and cable, environments hazardous to cabling where cable armouring may be necessary and electrical interference. Temperature Response Please note: For information and reference only. Data should not be used as pass / fail criteria for calibration purposes

Open the catalog to page 1
M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer - 2

M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer 5nC/bar nom. Metric Model Temperature Range Press./Vib Sensitivity Deviation re 20°C Case Material Case Seal Welded, hermetic diaphragm Welded, hermetic diaphragm Please note: For information and reference only. Data should not be used as pass / fail criteria for calibration purposes

Open the catalog to page 2

All DJB Instruments UK Ltd catalogs and technical brochures

  1. V3/04

    1 Pages

  2. VS1

    2 Pages

  3. CA/04/N,

    2 Pages

  4. CV1

    1 Pages

  5. CA/100/F

    1 Pages

  6. CA/04/V

    2 Pages

  7. VB/01

    1 Pages

  8. A/161

    1 Pages

  9. A/122/V

    2 Pages

  10. A/107/F

    1 Pages

Archived catalogs

  1. Connectors

    3 Pages

  2. Joiners

    1 Pages