1. Catalogs
  2. DJB Instruments UK Ltd
  3. M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer

M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer

M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer

M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer

Product catalog summary
Overview: The M/02/F and M/02/FA are piezoelectric dynamic pressure transducers designed for applications such as air blast measurement, combustion gas acoustic measurement, and fluid flow dynamics. They offer a nominal sensitivity of 5nC/bar and can operate at temperatures up to 250°C.
Specifications:
  • Sensitivity: 5nC/bar nominal
  • Weight: 46-56.5 grams
  • Maximum Temperature: 250°C
  • Pressure Sensitivity at 20°C: 0.51nC/bar for M/02/F and 5nC/bar for M/02/FA
  • Vibration Sensitivity: 23 pC/g max at 20°C
  • Capacitance: 1.4/1.9 nF for M/02/F and 2.8/5.0 nF for M/02/FA
  • Resonant Frequency: 90 kHz for M/02/F and 70 kHz for M/02/FA
  • Temperature Range: -50/+250°C (-58/+482°F)
  • Maximum Static Working Pressure: 200 bar
  • Case Material: Stainless Steel 303 S31
  • Connector: Microdot socket 10/32 UNF thread
  • Case Seal: Welded, hermetic diaphragm
  • Size: 23.7mm x 34.8mm for M/02/F and 36.6mm x 34.8mm for M/02/FA
Stability: Piezoceramics exhibit a logarithmic sensitivity decay over time. Initial exposure to high pressure and temperature results in sensitivity loss, but stability remains high (1-2% per year) if initial conditions are not exceeded. Thermal and load cycling is recommended to minimize long-term degradation.
Environmental Considerations: The M/02 series offers various signal outlet options for extreme conditions, including fluid immersion and environments hazardous to cabling. Cable armoring may be necessary to prevent electrical interference.
Additional Features:
  • Charge vs. pressure capability up to 200 bar
  • Wideband temperature calibration from -50 to +300°C
  • Proof pressure testing of transducers and assemblies up to 150 bar
  • Hermetic Microdot, TNC, and 7/16 UNS 2 pole connectors
  • Integral hardline cable termination
  • Case isolated signal for common mode rejection
  • Intrinsic safety version EEx ia II BT2 (Tamb.=300°C)
Note: The data provided is for informational purposes only and should not be used as pass/fail criteria for calibration.
See more

Catalog excerpts

M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer-1

M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer 5nC/bar nom. A smaller pressure transducer, doubling acoustic bandwidth, but at expense of 14dB reduction in sensitivity, thus 0.01pC noise equivalent acoustic signal threshold increases to 82dB (2.5mbar) M/02 application areas include air blast measurement, combustion gas acoustic measurement, fluid flow dynamics. Signals may be superimposed upon high static pressure backgrounds. Transducers are calibrated at ambient pressure. Options STABILITY Piezoceramics are subject to a logarithmic sensitivity decay vs. time. Exposure of piezoceramics to initial high pressure, temperature produces an initial sensitivity loss. Thereafter, subject to these initial conditions not being subsequently exceeded stability is exceedingly high, of the order 1 or 2%/1st yr. Transducers subject to high pressure/temperature should be thermally and load cycled to in build minimal long term degradation. charge vs. pressure up to 200bar wideband temperature calibration -50/+300°C proof pressure test of transducers, transducer/cable assemblies to 150bar hermetic Microdot, TNC & 7/16 UNS 2 pole connectors integral hardline cable termination case isolated signal for cmr Intrinsic Version EEx ia II BT2 (Tamb.=300°C), ENVIRONMENTAL M/02s have a variety of signal outlet options to cater for more extreme operating conditions. These encompass fluid immersion of transducer and cable, environments hazardous to cabling where cable armouring may be necessary and electrical interference. Temperature Response Please note: For information and reference only. Data should not be used as pass / fail criteria for calibration purposes

 Open the catalog to page 1
M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer-2

M/02/F & M/02/FA Piezoelectric Dynamic Pressure Transducer 5nC/bar nom. Metric Model Temperature Range Press./Vib Sensitivity Deviation re 20°C Case Material Case Seal Welded, hermetic diaphragm Welded, hermetic diaphragm Please note: For information and reference only. Data should not be used as pass / fail criteria for calibration purposes

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.