1. Catalogs
  2. DIVATEC,SL
  3. Flow meter M335/M350

Flow meter M335/M350

Flow meter M335/M350
1 / 12 PagesView full catalog

Flow meter M335/M350

Product catalog summary
Overview
The document details the technical specifications and operational guidelines for M335/M350 flow meters, which measure flow rates in closed pipelines using the float principle. These meters can measure between 50 to 60,000 liters per hour.
Functionality
The flow meters use a float that rises with the medium's flow, indicating the flow rate on dual scales for water and percentage measurements, with setpoint indicators.
Special Features
  • Fracture-proof and corrosion-resistant design.
  • Radially removable for easy maintenance.
  • Customizable adhesive scales for liquids and air up to 0.5 bar.
  • Accessory holders for limit value contacts and sensors.
  • Standard PVDF floats and stops.
  • Operating pressure of PN 10 (10 bar at 20°C water).
Materials and Chemical Resistance
Constructed from PVC, PA, and PSU, with PVDF components, these meters offer varying chemical resistance to acids, alkalis, inorganic, and organic compounds at 20°C.
Connection Options
Includes adhesive sockets, fusion spigots, and threaded sockets, with detailed dimensions provided.
Pressure Loss and Accuracy
Pressure loss values are specified for different ranges, with accuracy based on VDI/VDE 3513 guidelines, featuring a 5% error limit and a 50% linearity limit.
Installation and Operation
  • Install vertically and stress-free.
  • Maintain proper inlet (10x DN) and outlet (5x DN) lengths.
  • Avoid pressure surges.
  • Ensure leak-tightness before operation.
Accessories and Customization
Accessories include limit value contacts and sensors. Special scales can be customized based on medium, density, viscosity, range, and temperature.
Part Numbers and Dimensions
Part numbers and dimensions for M335 and M350 models are provided.
Specifications and Technical Data
Technical specifications are non-binding and subject to change, not guaranteeing quality or durability. General Terms and Conditions of Sale apply.
Flow Meter Calibration
Displayed values for air are corrected by multiplying by a factor corresponding to the operating pressure.
Accessories
Includes limit switches Z40.1 (min) and Z42.1 (max), and measurement sensor Z60, with further details in separate data sheets.
Installation Advice
Install vertically without tension, with specified inlet and outlet sections.
Operational Notes
Avoid pressure surges and solvent contact. Ensure all parts are tightened and leak-free before start-up.
Limit Value Contacts
Contacts Z40.1 and Z42.1 allow external monitoring of flow values, adjustable to any scale value, with a bistable switching function.
Measurement Sensor Z60
The Z60 sensor uses a microprocessor and sensors, providing a 4–20 mA output signal for process control or external display.
Assembly Instructions
Slide the sensor onto the guide, tighten screws, and wire according to specifications.
Measuring Range and Part Numbers
Lists measuring ranges in liters per hour with corresponding part numbers for ordering.
See more

Catalog excerpts

Flow meter M335/M350-1

Durchflussmesser M335/M350 Flow meter M335/M350 Zahlen I Daten I Fakten Figures I data I facts

 Open the catalog to page 1
Flow meter M335/M350-2

Funktionsweise Der Durchflussmesser M335/M350 arbeitet nach dem Schwe-bekorperprinzip und dient zur Durchflussmengenmessung in geschlossenen Rohrleitungen. Das Medium durchflieBt den ver-tikal eingebauten Durchflussmesser von unten nach oben. Der Schwebekorper wird dadurch angehoben und zeigt die momen-tane Durchflussmenge auf der am Messgerat angebrachten Skala an. Die Ablesekante entspricht dem groBten Durchmesser des Schwebekorpers. Die Durchflussmesser M335/M350 sind standardmaBig mit zwei Skalen ausgestattet: rechts eine Wasserskala, links eine %-Ska-la, zusatzlich zwei Sollwertanzeiger....

 Open the catalog to page 2
Flow meter M335/M350-3

Socket Spigot Plastic female thread Metal female thread PVC-Klebemuffe (Standard) PP-SchweiBstutzen PVC Edelstahl V4A PVC adhesive socket (standard) PP fusion spigot PVC Stainless steel V4A PP-SchweiBmuffe PVDF-SchweiBstutzen PP Temperguss PP fusion socket PVDF fusion spigot PP Malleable cast iron PVDF-SchweiBmuffe PE-SchweiBstutzen PVDF PVDF fusion socket PE fusion spigot PVDF Druckverlust mbar Pressure loss mbar Druckverlust mbar Pressure loss mbar Genauigkeitsklasse nach 2014 VDI/VDE 3513, Blatt 1 Dieser Messfehler kann mit einer mathematischen Formel berechnet werden. Der enthaltene relative...

 Open the catalog to page 3
Flow meter M335/M350-4

Messrohr-Werkstoff Fuhrungsstange, Schwebe- Measuring tube material korper, Anschlage Guide rod, float, stoppers Chemicalien Formel Konzentration PVC-U PA Chemicals Formula Concentration Phosphorsaure | Phosphoric acid H3PO4 < 75 % Schwefelsaure | Sulfuric acid H2SO4 < 78 % Salpetersaure | Nitric acid HNO3 < 58 % Salpetersaure | Nitric acid HNO3 67 % Flusssaure | Hydrofluoric acid HF < 40 % Salzsaure | Hydrochloric acid HCI < 36 % Natronlauge | Caustic soda NaOH < 40 % Eisenchlorid | Ferric chloride FeCI_3 Chlorbleichlauge | Chlorine bleaching NaOCl < 6 % Natriumbisulfit | Sodium bisulfite NaHSO3...

 Open the catalog to page 4
Flow meter M335/M350-5

Messbereich l/h H2O Klebemuffe SchweiRmuffe Stutzen PP Stutzen PVDF Gewindemuffe Measuring range l/h H2O Adhesive socket Fusion socket Spigot PP Spigot PVDF Threaded socket Messbereich l/h H2O Klebemuffe SchweiRmuffe Stutzen PP Stutzen PVDF Gewindemuffe Measuring range l/h H2O Adhesive socket Fusion socket Spigot PP Spigot PVDF Threaded socket Verschraubung mit SchweiBstutzen Connection with fusion spigot Verschraubung mit Gewindemuffe Connection with threaded socket

 Open the catalog to page 5
Flow meter M335/M350-6

Measuring tube Messbereich l/h Schwebek. PVDF Measuring range l/h Art.-Nr. Float PVDF Part no. Schwebek. PVDF/Magnet Schwebek. PVDF Art.-Nr. Art.-Nr. Float PVDF/Magnet Float PVDF Schwebek. PVDF/Magnet Art.-Nr. Float PVDF/Magnet Part no. Measuring tube Measuring tube Industrial Plastic Valves

 Open the catalog to page 6
Flow meter M335/M350-7

Sonderskalen Special scales H2O l/h Luft 0 bar Art.-Nr. Air 0 bar Part no. NaOH 30 % Art.-Nr. NaOH 30% Part no. NaOH 50 % Art.-Nr. NaOH 50% Part no. Sonderskalen (maßgeschneidert) nach Kundenwunsch Special (customized) scales on customer request Erforderliche Angaben: Details required: • Dynamische Viskosität in cP oder mPa*s • Dynamic viscosity in cP or mPa*s • Desired measuring range in l/h Application instructions for special scales Beim nachträglichen Anbringen von Sonderskalen ist darauf zu achten, dass die Markierung ◄ auf de

 Open the catalog to page 7
Flow meter M335/M350-8

Weitere Hinweise siehe separate Datenblatter. • Durchflussmesser senkrecht und spannungsfrei in das Rohrleitungssystem einbauen • Ein- und Auslaufstrecke vorsehen, Einlauf ca. 10 x DN, Auslauf ca. 5 x DN • Druckschlage vermeiden, da diese zur Beschadigung des Gerates fuhren konnen • Vorsicht beim Einbau: Das Messrohr darf nicht mit Losungsmittel in Beruhrung kommen! • Vor Inbetriebnahme Anschlussteile auf ausreichendes Anzugsmoment uberprufen Technische Anderungen vorbehalten. For further information, refer to the separate data sheets. • Install the flow meter into the pipeline system vertically...

 Open the catalog to page 8
Flow meter M335/M350-9

Anwendung Die Grenzwertkontakte Z 40.1 und Z 42.1 dienen zur externen Uberwachung von begrenzten Durchflusswerten an unseren (Schwebekorper-)Durchflussmessern. Sie werden auf die am Durchflussmessgerat befindliche Fuhrung aufgeschoben und lassen sich auf jeden beliebigen Wert der entsprechenden Skala einstellen. Ein im Schwebekorper eingebauter Magnet schlieBt oder offnet einen im Grenz-wertkontakt fest vergossenen Reedkon-takt. Die Schaltfunktion ist bistabil. Das heiBt, der Schaltzustand bleibt erhalten, auch wenn der Magnetschwebekorper vom Kontakt entfernt ist. The limit value contacts Z...

 Open the catalog to page 9
Flow meter M335/M350-10

Messwertsensor Z 60, 4–20 mA Ausgangssignal Measurement sensor Z 60, 4–20 mA output signal Für Durchflussmesser M335/M350 For float-type flow meters M335/M350 Beschreibung Der Messwertsensor Z 60 ist eine Weiterentwicklung des Messwertsensors Z 50. Im Gegensatz zum Vorgängermodell werden beim Z 60 keine Reedkontakte verwendet, sondern eine spezielle, neu entwickelte Elektronik mit Mikroprozessor und Sensoren. The Z 60 measurement sensor is a further development of the Z 50 measurement sensor. In contrast to the predecessor model, the Z 60 no longer uses reed contacts, but a new, specially developed...

 Open the catalog to page 10
Flow meter M335/M350-11

a Durchflussmesser M335/M350 mit Magnetschwebekorper b Messwertsensor Z60 c Steckverbindung d Fuhrungsschiene e Klemmschrauben zur Befestigung und Justierung des Sensors 1. Sensor auf die Fuhrungsschiene des Durchfluss-messers schieben 3. Stecker abnehmen und gemaB Vorgabe (siehe „Elektrischer Anschluss11) verdrahten a M335/M350 flow meters with magnet float b Z60 measurement sensor c Plug connector d Guide e Clamping screw for attaching and adjusting the sensor 1. Slide the sensor onto the guide of the flow meter 2. Tighten clamping screws 3. Remove connector and wire it according to specifications...

 Open the catalog to page 11

All DIVATEC,SL catalogs and technical brochures

  1. Bend 90°

    84  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry