QG65-KI-360H-CAN-C(F)M
2Pages

{{requestButtons}}

Catalog excerpts

QG65-KI-360H-CAN-C(F)M - 1

QG65-KI-360H-CAN-C(F)M Inclination sensor 1 axis vertical mounting Output CANopen Supply voltage 10 - 30 V dc Measuring range 360° Dimensions (indicative) Mounting Ingress Protection (IEC 60529) Relative humidity Weight Supply voltage Polarity protection Current consumption Operating temperature Storage temperature Measuring range Centering function Frequency response (-3dB) Accuracy (2a) Offset error Reinforced plastic injection molded (Faradex DS, black, EMI shielded by stainless steel fiber in PC) 60x50x27 mm 4x M5x25 mm zinc plated pozidrive screws included (optional: 2x 04mm positioning pins) IP67 Non linearity Sensitivity error Resolution Temperature coefficient Max mechanical shock CAN interface (hardware) CAN communication profile Baud rate Node Id TPDO Event time Sync mode Heartbeat Programming options Output format Temperature compensation Filtering Modes of operation_ Boot time overall 0,07° typ. < ± 0,05° typ. after centering < ± 0,06° typ. (< ± 0,1° max.) not applicable 0,01° ± 0,005°/K typ. 20.000g CAN 2.0 A and B according to ISO 11898-1 & ISO 11898-2 CANopen, CiA301 V4.2.0 & EN 50325-4 125 kbit/s (default), 250 kbit/s, 500 kbit/s, 1 Mbit/s 01 h (range: 01h - 7Fh) TPDO1: 181h (for Node ID=01h) TPDO1: 5 - 500 ms (default: 100 ms) On/off (default: off) On/off (default: on, 2s) Baudrate, Node Id, Event time, Sync mode, Heartbeat, Output format Integer: 0 to 35999 (PDO1:byte2,1) Yes Input filter enabled, output filter disabled _Event mode, Sync-mode_ < 1 s © DIS Sensors - Oostergracht 40 - 3763 LZ SOEST - The Netherlands www.dis-sensors.com Subject to change without notice

Open the catalog to page 1
QG65-KI-360H-CAN-C(F)M - 2

Measurement orientation Rotation in vertical plane. Lateral tilt sensitivity error: < ± 0,03°/° lateral tilt (typ.) Max. lateral tilt: 45° Drawn in the default 0° position. Connectivity (length ±10%) Connection Male only or Male & Female (internal T-junction) M12 connector (5 pins, A-coding) ( CiA303 V1.8.0 ) (Brass Nickel coated, contacts copper alloy) No bus termination inside. A CANbus always has to be terminated properly. For bus termination order seperate M12 termination resistor (optional: T-connector) Pin 1: Shield Pin 2: Vcc Pin 3: Gnd & CAN_GND Pin 4: CAN_H Pin 5: CAN_L Mechanical...

Open the catalog to page 2

All DIS Sensors catalogs and technical brochures

  1. 5p, female

    2 Pages

  2. 5p, male

    2 Pages

Archived catalogs