QG65-KD-030H-CAN-C(F)M
2Pages

{{requestButtons}}

Catalog excerpts

QG65-KD-030H-CAN-C(F)M - 1

QG65-KD-030H-CAN-C(F)M Inclination sensor 2 axis horizontal mounting Output CANopen Supply voltage 10 - 30 V dc Measuring range ± 30° Dimensions (indicative) Mounting Ingress Protection (IEC 60529) Relative humidity Weight Supply voltage Polarity protection Current consumption Operating temperature Storage temperature Measuring range Centering function Frequency response (-3dB) Accuracy (2a) Offset error Non linearity Sensitivity error Resolution Temperature coefficient Max mechanical shock CAN interface (hardware) CAN communication profile Baud rate Node Id TPDO Event time Sync mode Heartbeat Programming options Output format Temperature compensation Filtering Modes of operation_ Boot time Reinforced plastic injection molded (Faradex DS, black, EMI shielded by stainless steel fiber in PC) 60x50x27 mm 4x M5x25 mm zinc plated pozidrive screws included (optional: 2x 04mm positioning pins) IP67 overall 0,04° typ. < ± 0,03° typ. (< ± 0,08° max.) after centering < ± 0,02° typ. (< ± 0,07° max.) not applicable 0,01° ± 0,005°/K typ. 20.000g CAN 2.0 A and B according to ISO 11898-1 & ISO 11898-2 CANopen, CiA301 V4.2.0 & EN 50325-4 125 kbit/s (default), 250 kbit/s, 500 kbit/s, 1 Mbit/s 01 h (range: 01h - 7Fh) TPDO1: 181h (for Node ID=01h) TPDO1: 5 - 500 ms (default: 100 ms) On/off (default: off) On/off (default: on, 2s) Baudrate, Node Id, Event time, Sync mode, Heartbeat, Output format Integer: -3000 to +3000 (PDO1:X=byte2,1;Y=byte4,3) Yes Input filter enabled, output filter disabled _Event mode, Sync-mode_ < 1 s © DIS Sensors - Oostergracht 40 - 3763 LZ SOEST - The Netherlands www.dis-sensors.com Subject to change without notice

Open the catalog to page 1
QG65-KD-030H-CAN-C(F)M - 2

CANoutput = 100*α Clipping outside measuring range Measurement orientation Default 0°: horizontal (label upwards), no acceleration applied. Cross tilt sensitivity error: < (0,12 * cross tilt angle)² % typ. → one axis <10° tilt for max. accuracy Connectivity (length ±10%) Connection Male only or Male & Female (internal T-junction) M12 connector (5 pins, A-coding) ( CiA303 V1.8.0 ) (Brass Nickel coated, contacts copper alloy) No bus termination inside. A CANbus always has to be terminated properly. For bus termination order seperate M12 termination resistor (optional: T-connector) Pin 1:...

Open the catalog to page 2

All DIS Sensors catalogs and technical brochures

  1. 5p, female

    2 Pages

  2. 5p, male

    2 Pages

Archived catalogs