The modular expandable, configurable, multifunctional safety system Brief description

Open the catalog to page 1
slvariobriefdescription - 2

DINA Elektronik GmbH 72649 Wolfschlugen Esslinger Str. 84 Tel: 07022 95170 Fax: 07022 951751 Info@dinaelektronik.de www.dinaelektronik.de The direct way to safe automation The product is designed according to the following standards: • 2004/108/EC: EMC-directive • GS-ET-20: basic principles for testing and certification of safety switch devices • DIN EN 60947-5-1: Low-voltage switch gear and control gear; part 5.1: Control circuit devices and switching elements - electromechanical control circuit devices • DIN EN 62061: Functional safety of safety-related electrical, electromechanical and...

Open the catalog to page 2
slvariobriefdescription - 3

SLV/\RID Brief Description Product description The product SL\//\RID is a multi-functional, modular, expandable and configurable safety system. It consists of a central module and different functional modules. The central module is mounted in a 45mm or 67.5mm plastics housing depending on the quantity of outputs. All versions of functional modules are mounted in a 22.5mm plastics housing. They are plugged together with a bus connector at the bottom of the housing. The bus plug is a component part. One application can contain one up to 15 modules. The modules can be fixed on a 35mm standard...

Open the catalog to page 3
slvariobriefdescription - 4

Modules Id-No. Central module DNSL-ZMVK DNSL-DSV DNSL-DRV Speed monitoring DNSL-SIV Speed monitoring Brief Description DNSL-RMV 40RM01 Relay module Description 4 speed monitoring with one proximity switch or (1) 2 safe speed and standstill monitoring with 2 proximity switches or (2) 2 safe speed and standstill monitoring with HTL-encoder 8 safe analogue or digital inputs, free configurable 8 safe digital inputs, free configurable 4 safe digital inputs, configurable as safe outputs or clock outputs 2 inputs for power supply 1 USB interface for data transfer 6 safe outputs, positive switching...

Open the catalog to page 4
slvariobriefdescription - 5

SL Inputs for safety functions The following table shows SL and non-safety relevant functions. Module DNSL-ZMV DNSL-ZMVK DNSL-DSV DNSL-DRV DNSL-SIV DNSL-INV DNSL-IOV DNSL-RMV DNSL-NIV DNSL-FBV Brief Description modules with their available inputs. These can be used for different safety Designer symbol I: Inputs IO: In-, Outputs DNSL-FBV applies to all fieldbus interfaces Analogue inputs at the central module and their usage I1 to I8 safe inputs for safety shutdown mats I1 to I8 safe analogue inputs for 0 to 10V I1 to I4 safe analogue inputs for 4 to 20mA Usage of the comparator function...

Open the catalog to page 5
slvariobriefdescription - 6

Brief Description Terminal inputs for safety circuits (SC) with manual quit Safety circuit / description / inputs 1 2 3 4 Module E11 E12 Q1 E21 E22 Q2 E31 E32 Q3 E41 E42 Q4 DNSL-ZMV /K I1 I2 I3 I5 I6 I7 I9 I10 I11 I13 I14 I15 DNSL-DSV I1 I2 I3 I5 I6 I7 DNSL-DRV I1 I2 I3 I5 I6 I7 DNSL-SIV I1 I2 I3 I5 I6 I7 DNSL-INV I1 I2 I3 I5 I6 I7 I9 I10 I11 DNSL-IOV I1 I2 I3 I5 I6 I7 DNSL-RMV I1 I2 I3 I5 I6 I7 DNSL-NIV I1 I2 I3 I5 I6 I7 DNSL-FBV I1 I2 I3 I5 I6 I7 FBV applies to all fieldbus interfaces Safety function emergency stop with manual quit via the 3rd input In the following example the module...

Open the catalog to page 6
slvariobriefdescription - 7

Brief Description Safety function protection cover with quit via the Q-input In the following example the module DNSL-DSV is used. The number 2 shows the position of the module in the application. The virtual output of the safety circuit (SC) is placed at the right bottom side of the Designer symbol. The storage time (Q) for the quit signal can be off-delayed with a timer. Static parallel Static antivalent Clock from SL Safety technology Input for LOW signal is green

Open the catalog to page 7
slvariobriefdescription - 8

Brief Description Terminal inputs at the central module (19 to 116) for speed monitoring 4 one channel speed monitoring, each with one proximity switch and one safe speed monitoring via HTL-encoder The Designer symbol displays one channel monitoring with a green and safe monitoring with a yellow symbol in the upper left corner. One safe monitoring via 2 proximity switches, two one channel safe monitoring via HTL-encoder. With the inputs 19 to 112 two monitoring each with one proximity switch and one safe monitoring are possible, 19 with 110 for the first Standstill^ signals function modes...

Open the catalog to page 8
slvariobriefdescription - 9

Brief Description Plug inputs at DNSL-DSV for 2 speed monitoring using feedback measurement systems Monitoring / Inputs flowchart Designer symbols Module Axis 1 Axis 2 Axis 1 Axis 2 Encoder 1 Encoder 2 RJ45 RJ45 Sin / Cos 1Vpp oder TTL 1-5V, 500KHz DNSL-DSV Standstill, position direction and speed in different function modes can be monitored. HTL Signals via Cable adapter Type DNRJ 45-SL-HTL Measurement system (encoder) requirements for speed monitoring Sinus / Cosine and TTL HTL • Amplitude 1Vpp Sinus / Cosine or TTL • Amplitude 1 to 24V square wave. • Encoder frequency ≤ 496937Hz •...

Open the catalog to page 9
slvariobriefdescription - 10

Brief Description Function of the virtual inputs and outputs at the symbols of the speed monitoring MT1 , MT2 : Inputs for mute function : Output to unlock the safety cover at standstill Output for safe speed monitoring (SSM) n F11 bis F23 : Inputs for mode selector Output for safe direction monitoring (SDI) BR1 , BR2 : Outputs for safe monitoring of the : deceleration (SAR) n After a quit via the virtual input RTDS the virtual output has a HIGH signal if the measurement system is working properly. Standstill is monitored if none function mode via the inputs F11/F21, F12/F22, F13/F23 and...

Open the catalog to page 10
slvariobriefdescription - 11

Brief Description 6 safe outputs, positive switching 4 safe outputs, positive switching or 4 safe digital inputs Every safety circuit can be configured 2 outputs each with one NO contact The Designer is used to configure all functions. Various diagnostic options are available to enable the commissioning and debugging. Safety technology SlX//\Rin Version2 Date: 2012-11-14 page 11 of 12

Open the catalog to page 11
slvariobriefdescription - 12

DINA Elektronik GmbH

Open the catalog to page 12

All DINA Elektronik GmbH catalogs and technical brochures

  1. SAFEONE DN3PD2

    42 Pages

  2. SAFELINE VARIO

    71 Pages

  3. DNDS modular

    31 Pages

  4. dn3pwe

    3 Pages

  5. dn3ps2e

    8 Pages

  6. dnco1

    8 Pages