Product catalog summary
Overview: The SafeLine instruction manual offers detailed guidance on the hardware components and safety technology for SafeLine Designer 2. It covers specifications, compliance information, and descriptions of various modules and their functionalities.
Certification and Compliance: The product complies with the machinery directive 2006/42/EC, EMC-directive 2004/108/EC, DIN EN 60947-5-1, and DIN EN 62061. It meets SIL CL3 safety integrity requirements and has a PFHD of 6.28 x 10-8. Certifications are provided by institutions like ELMAC GmbH and DQS, Frankfurt.
Product Description: SafeLine includes central modules (DNSL-ZM, ZMA, ZMB, etc.), input/output modules, relay modules, and field bus modules, each designed for specific functions such as motion monitoring and network communication.
Modules and Functions: The manual details functionalities of central modules with field buses, function modules, and interface modules, including configuration and usage of virtual outputs, safety circuits, and motion monitoring systems.
Safety Features: Safety features include two-hand control devices, emergency stop functions, and brake monitoring. Guidelines for setting up safety circuits and monitoring motion using proximity switches are provided.
Installation and Configuration: Instructions for assembling cascades, configuring terminals for digital and analogue inputs, and setting up safety shut down mats are included, along with schematics for outputs and safe contacts at central modules.
Usage Recommendations: Emphasis is placed on adhering to safety regulations and intended usage guidelines to ensure safe operation of the SafeLine system.
Specifications: Specifications for SafeLine Designer 2 hardware include modules like DNSL-IO, IO2, and DNSL-IN, with details on configurable contact outputs, dimension diagrams, and assembling procedures.
Safety Regulations: Installation and operation must be conducted by qualified electrical engineers familiar with safety regulations, adhering to VDE, EN, and local regulations to prevent accidents. Unauthorized modifications are warned against, and proper disposal at the end of the unit's service life is stressed.
Intended Usage: The SafeLine series is designed for safety-relevant functions in machinery and equipment, suitable for use as a logic unit in two-hand control devices.
Modules and Interfaces: Details on central modules with COM and USB ports, and field bus modules like PROFIBUS, CAN OPEN, and ETHER CAT are provided, including configuration of inputs and outputs using SafeLine Designer SLD2 software.
Field Bus Modules: Available field bus modules include DNSL-DP for PROFIBUS DP, DNSL-FB for ETHER CAT, and CAN OPEN, each with specific input and output data capacities.
Central Modules: Central modules like DNSL-ZMB, DNSL-ZMR, and DNSL-ZMT are equipped with COM PORT and USB PORT interfaces for data transfer, supporting various input and output configurations.
Interface Options: Modules offer V24 (COM PORT) and USB interfaces for data transfer, with field bus mounted on a separate pluggable module. Memory card functionality allows storage and access of user applications and documentation.
Function Modules: Function modules like DNSL-DS, DNSL-DR, DNSL-IN, DNSL-IO, DNSL-IO2, DNSL-KM, and DNSL-RM230 provide functionalities such as dual standstill and motion monitoring, input/output configurations, and safety contact outputs.
Configuration and Software: Configuration of inputs, outputs, and other functions is done using SafeLine Designer SLD2 software, with detailed instructions in the Designer manual SLD2.
Safety and Compliance: Modules are tested for safety and comply with standards like BG-PRUFZERT ET 11070, designed for use in multifunctional safety systems.
Procedures: Configuration of inputs and outputs is performed using SafeLine Designer SLD2, with data transfer facilitated through RJ45 sockets. Memory card integration and data transfer procedures are outlined for DNSL-MC and DNSL-PR.
Recommendations: Correct wiring and configuration are crucial to avoid malfunctions, as indicated by LED signals. Specified modules and configurations should be used to maintain system safety and functionality.
Key Data: Connection schemes and LED indicators for monitoring the status of inputs, outputs, and power supply across various modules are included.
Specifications: Specifications for motion monitoring modules include virtual outputs for brake monitoring, standstill, and maximum speed, with requirements for the measurement system specified.
Procedures: Selection of function modes for motion monitoring is controlled via a mode selector switch and permission key, with priority of virtual inputs and configuration of the DNCO function for speed monitoring explained.
Standards and Norms: Use of safe semiconductor outputs and safe contacts at central modules is specified, with emphasis on monitoring outputs for errors.
Recommendations: Manual resets are recommended for certain safety functions, and outputs should be configured via the SLD2 parameter table for optimal safety and functionality.
Key Data from Tables and Diagrams: Tables for terminal digital inputs and outputs and diagrams for output schematics illustrate configurations for safe and configurable outputs.
Critical Information: Key requirements include maintaining high signal outputs during standstill and ensuring proper configuration of virtual inputs and outputs for safety functions, with adherence to specified encoder requirements and monitoring outputs for errors emphasized.
See more

Catalog excerpts

safelinehardwaresld2e-1

Original Instruction manual Hardware

 Open the catalog to page 1
safelinehardwaresld2e-3

Original instruction manual DlNA Elektronik GmbH Esslinger Straße 84, 72649 Wolfschlugen Declaration of Conformity according to the machinery directive 2006/42/EC attachment II 1A The protection target of the low voltage directive will be fulfilled according to attachment I. 1. 5. 1 of the machinery directive. Producer: Address: DINA Elektronik GmbH Esslinger Str. 84, D-72649 Wolfschlugen The producer declares, that the product SafeLine with the module types as follows DNSL-ZM DNSL-ZMA DNSL-ZMB DNSL-ZMK DNSL-ZMR DNSL-ZMT Central module Central module Central module Central module Central module...

 Open the catalog to page 3
safelinehardwaresld2e-4

Original instruction manual The direct way to safe automation Unlock 72649 WOLFSCHLUGEN Unlock Lock ID-No: 24EC43 FELDBUS SLAVE 72649 WOLFSCHLUGEN Unlock Lock DINA ELEKTRONIK D-72649 WOLFSCHLUGEN Unlock Lock DINA ELEKTRONIK Unlock Lock MULTIFUNCTIONAL SAFETY SYSTEM INPUT OUTPUT MODULE DINA ELEKTRONIK D-72649 WOLFSCHLUGEN Unlock Lock MULTIFUNCTIONAL SAFETY SYSTEM INPUT MODULE DINA ELEKTRONIK 2 HANDFUNCTION: EN 574 TYPE IIIC ID-No: 24EC43 FELDBUS SLAVE 2 HANDFUNCTION: EN 574 TYPE IIIC DINA ELEKTRONIK D-72649 WOLFSCHLUGEN Unlock Lock IND.CONT.EQ 1ZD7 Certification data DIN EN 62061, SIL CL 3 Two-Hand-Control...

 Open the catalog to page 4
safelinehardwaresld2e-5

Original instruction manual Hardware for SafeLine designer 2

 Open the catalog to page 5
safelinehardwaresld2e-6

Original instruction manual Products: safety technology Hardware for SafeLine designer 2

 Open the catalog to page 6
safelinehardwaresld2e-7

Original instruction manual Safety regulations • The unit may only be installed and operated by those who are qualified electrical engineers or have received sufficient training and are familiar with both these instructions and the current regulations for safety at work and accident prevention. Follow VDE, EN as well as local regulations especially as regards preventative measures! • Ignoring the safety regulations can lead to death, serious injury or cause considerable damage! • In emergency stop applications use the internal function “Speed output restart disable” or a higher level control...

 Open the catalog to page 7
safelinehardwaresld2e-8

Original instruction manual Product description SafeLine is housed in a metal rack type enclosure. It can be mounted by spring fasteners to a DIN rail. The individual functional modules are pluggable. The equipment is available in different housing sizes, depending on the number of functional modules to be used. Up to 15 functional modules may be used. Racks with 2, 3, 5, 7, 9, 13 and15 slots are available. Unused slots are covered with a blind cover. (Article No. 10BD00) All modules are plugged into the redundant backplane bus system. Every unit contains only one central module. The number of...

 Open the catalog to page 8
safelinehardwaresld2e-9

Central modules with possible field bus modules Available field bus modules Sbherheit gepruft ^tested safety DINA ELEKTRONIK DINA ELEKTRONIK Unlock Lock DINA ELEKTRONIK Unlock Lock CUfUllSLISTED Q.ZD.£ ^INDjCONT.EO gQ{f)l— Sbherheit gepruft DINA ELEKTRONIK Unlock ^r^=a Sicherheit gepruft tested safety^ Lock A^^~T> Lock A.^J"r~T> All central modules above are available on request with further field bus modules. Products: safety technology Hardware for SafeLine designer 2 redaction 12 date 2012-02-16 Page 9 of 51

 Open the catalog to page 9
safelinehardwaresld2e-10

Original instruction manual Type DNSL-ZM Features 6 safe digital inputs, free configurable 4 safe positive switching outputs 2 positive switching outputs, free configurable 1 positive switching output, system ready See DNSL-ZM DNSL-ZMA COM PORT USB PORT 6 safe digital inputs, free configurable 1 analogue input 2 safe positive switching outputs 1 positive switching output, system ready See DNSL-ZMA DNSL-ZMK COM PORT USB PORT 6 safe digital inputs, free configurable 2 safe positive switching outputs 1 contact output with 2 safe contacts 1 positive switching output, system ready See DNSL-ZMK Field...

 Open the catalog to page 10
safelinehardwaresld2e-11

Unlock Lock COM PORT PROFIBUS-DP SLAVE 2 HANDFUNCTION: EN 574 TYPE IIIC Sicherheit geprüft tested safety Unlock Lock Unlock Lock Sicherheit geprüft tested safety COM PORT PROFIBUS-DP SLAVE 2 HANDFUNCTION: EN 574 TYPE IIIC tested safety MULTIFUNCTIONAL SAFETY SYSTEM www.dinaelektronik.de PROFIBUS-DP SLAVE MULTIFUNCTIONAL SAFETY SYSTEM www.dinaelektronik.de COM PORT 2 HANDFUNCTION: EN 574 TYPE IIIC DNSL-ZMT-DP with USB PORT Unlock Lock 2 HANDFUNCTION: EN 574 TYPE IIIC Sicherheit geprüft tested safety DNSL-ZMR-DP with USB PORT PROFIBUS-DP SLAVE 2 HANDFUNCTION: EN 574 TYPE IIIC tested safety PROFIBUS-DP...

 Open the catalog to page 11
safelinehardwaresld2e-12

Original instruction manual Central modules with or without PROFIBUS DP Type Id-No. Features DNSL-ZMB-DP COM PORT 24ZB22 16 safe digital inputs, free configurable USB PORT 24ZB32 2 safe positive switching outputs 1 contact output with 2 safe contacts DNSL-ZMB COM PORT 24ZB20 1 positive switching output, system ready USB PORT 24ZB30 dual motion and standstill monitoring via the inputs I11 to I14 See DNSL-ZMB DNSL-ZMR-DP COM PORT USB PORT safe digital inputs, free configurable safe positive switching outputs positive switching outputs, free configurable positive switching output, system ready dual...

 Open the catalog to page 12
safelinehardwaresld2e-13

Original instruction manual LINE QiJ^flK Central modules with different field bus modules |Unlock„ Lock LockY ^Unlock LockY ^Unlock Unl°<* Y^jS The data transfer interface, a V24 (COM PORT) respectively an USB (USB PORT) is mounted at a separate pluggable module. This module is a part of the central module. The user application and all other documentations can be stored on a memory card, if there is a Field bus with an USB PORT. The memory card answers as a drive. Configuring the inputs, outputs and other functions use SafeLine Designer SLD2. See Designer manual SLD2. Products: safety technology...

 Open the catalog to page 13
safelinehardwaresld2e-14

Original instruction manual PROFIBUS DP Interface COM PORT, Fieldbus and 8 safe digital inputs Interface COM PORT and Fieldbus ID-No: 24CO40 FELDBUS SLAVE ID-No: 24EC42 FELDBUS SLAVE ID-No: 24CO42 FELDBUS SLAVE DINA ELEKTRONIK DINA ELEKTRONIK DINA ELEKTRONIK DINA ELEKTRONIK 72649 WOLFSCHLUGEN Unlock Lock Interface USB PORT, field bus and 8 safe digital inputs ID-No: 24EC41 FELDBUS SLAVE ID-No: 24CO41 FELDBUS SLAVE ID-No: 24EC43 FELDBUS SLAVE ID-No: 24CO43 FELDBUS SLAVE DINA ELEKTRONIK D-72649 WOLFSCHLUGEN Unlock Lock 72649 WOLFSCHLUGEN Unlock Lock Interface USB PORT with field bus 72649 WOLFSCHLUGEN...

 Open the catalog to page 14

All DINA Elektronik GmbH catalogs and technical brochures

  1. SAFEONE DN3PD2

    42  Pages

  2. SAFELINE VARIO

    71  Pages

  3. DNDS modular

    31  Pages

  4. dn3pwe

    3  Pages

  5. dn3ps2e

    8  Pages

  6. dnco1

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.