DN3PS2 Standstill monitoring without Sensorik Original Instruction Manual

Open the catalog to page 1
dn3ps2e - 2

and three phases Motors without sensor system DCAVG : Middle Proof Test Interval: 1/year EMC standard certified by ELMAC GmbH Bondorf, Quality management system DINA Elektronik GmbH, Esslinger StraBe 84, 72649 Wolfschlugen

Open the catalog to page 2
dn3ps2e - 3

Original Instruction manual Declaration of Conformity according to the machinery directive 2006/42/EC attachment II 1A The protection target of the low voltage directive will be fulfilled according to attachment I. 1. 5. 1 of the machinery directive. Producer: Address: DINA Elektronik GmbH Esslinger Str. 84, D-72649 Wolfschlugen The producer declares that the product DN3PS2 is conformable with the regulations of the directives stated above. Testing based on: EN ISO 13849-1:2008 + AC: 2009 EN 61508 Parts 1- 7:2010 EN 50178:1997 EN 55011:2007 +A2:2007 Intended usage The equipment fulfills the...

Open the catalog to page 3
dn3ps2e - 4

Original Instruction manual Equipment description The input terminals L1, L2 and L3 have to be always directly connected to the power supply terminals of the monitored drive. No switching contacts are allowed between L1, L2, L3 and the terminals of the drive. There is a 4KV electrical isolation between L1, l2, L3 and all other terminals of DN3PS2. The output contacts at the terminals 13-14 and 23-24 are safe redundant NO contacts stop category 0 according to EN 60204-1. The contacts can be used as two-channel (parallel) or serial safety circuit. Diagram 1a: Delta-connection 3-phases motor...

Open the catalog to page 4
dn3ps2e - 5

Original Instruction manual Table 2: Adjustment range of the standstill switching value Value 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 LED b8 / OK b4 / STOP b2 b1 Contacts closed [mV] 50 55 60 65 70 75 80 200 230 250 300 350 400 460 500 Contacts open [mV] 120 120 120 120 120 120 120 1000 1000 1000 1000 1000 1000 1000 1000 ON-delay time of the output contacts The button SET has to be activated for approximately 6s, till all LED are flashing green. After the actuation of the button SET the LED are flashing accordingly to the binary combination of the actual parameters adjustment. The value of the...

Open the catalog to page 5
dn3ps2e - 6

Original Instruction manual Safety cover monitoring The monitoring is permanently active during the function mode FA1. The safety cover is only unlocked, if the drive is in standstill (Diagram 3a) 1)emergency stop 3)safety cover 5)tool 7)drive 9)safety cover switch 2)process unit 4)cover open/ closed 6)drive power supply 8)EMF-Sensor wire 10)safety cover enabling Standstill monitoring The standstill monitoring is inactive, if the control inputs I11 and I21 are connected to 24V DC via the safety cover switch and the safety cover is closed. The output contacts are permanently closed. The LED...

Open the catalog to page 6
dn3ps2e - 7

Original Instruction manual DN3PS2 St-'JstandEubc™aehiMig inhjber BeslimmuntiaaemalSfl Das Gflf3t erlullL die Anfanjerumgen der PrLrrgrundiagcn (KM 4 / PL a nach Verwendung EN ISO 13*49-1. SIL CL 3 nsrJn EN &3061. 3IL 3 natfi tN 815WI una KBnn m Arv*BH*ingen b* Kai 4 .■PL e nach EN ISO 13349-1 und SIL 3 nacr EN Besnncirrc Die HinwciSt in der zugehOrigen tnslaJlatons- und Belriclwanleilung sind zu Bedmgungwi Dfcflcnien. Eb vviiO Ueitatigt dB3& der Prtrfgescnatond mrt don AnFOfdarungon r»ach Anh*ng l ripr Rimtlin* 20Q6M2/EG uber MBSdiinen otwrvintlimmL ^ncton*" Solely Type ApurWrtd Dtv...

Open the catalog to page 7

All DINA Elektronik GmbH catalogs and technical brochures

  1. SAFEONE DN3PD2

    42 Pages

  2. SAFELINE VARIO

    71 Pages

  3. DNDS modular

    31 Pages

  4. dn3pwe

    3 Pages

  5. dnco1

    8 Pages