Catalog excerpts
Original instruction manual Safety switchgear unit to monitor the speed of 3-phases and single phase motors without sensor +55°C
Open the catalog to page 1Folgende Normen sind angewandt: Following standards are used: Les normes suivantes sont appliquees: Vengono applicate le seguenti norme: Se utilizan los siguientes estandares: Zusatzanforderung: Supplementary requirements Fur Frequenzen oberhalb des parametrierten Bereiches: Das Gerat erfullt die Anforderung der Kat. 4/ PL e nach ISO 13849-1, SIL (CL) 3 nach IEC 62061 und IEC 61508 Fur Frequenzen unterhalb des parametrierten Bereiches: Das Gerat erfullt die Anforderung der Kat. 1/ PL c und SIL (CL) 1 For the frequencies above the parameterized range: The module meets the Cat. 4/ PL e acc....
Open the catalog to page 32.3. Order Data 3 Safety regulations 4 Important notes and validation 4.4. V-LIMIT 1: minimal speed 4.5. V-LIMIT 2: Maximal speed 5 Usage 5.1. Operation with frequency converter 5.2. Operation at motors with star-triangle 5.3. Operation at alternating current (AC) motors 5.4. Schematic, control elements and display 6 Installation and remove G.l. Wiring 7.1. Important notes to the Configuration 7.2. Configuration of the switching threshold and quit-function 7.5. Frequency table Table 7-1: Confuguration using column and line 7.G. Diagram 9-2: Example according to table...
Open the catalog to page 42 Intended use • The safety switchgear unit is for the monitoring of a minimal and a maximal speed of drives using by machine tools without sensors. • According to VDE 0113 T.1 the unit can be used in safety current circuit. • Depending on the external wiring maximal category 4/ PLe according to EN IOS 13849-1 respectively SIL 3 according to EN 61508 can be achieved. (•'\ This document is to use for the product DN3PD1 and is according the contently requirements of an original instruction manual Original Instruction Manual 04/18 Date: 2018-02-20 5 of 16
Open the catalog to page 53 Safety regulations • The device must only be installed and activated by an electrician or trained persons who are familiar with these operating instructions and the applicable regulations regarding work safety and accident prevention. • Observe the VDE, EN and local regulations, particularly respecting to the protective measures. • Without observing the regulations may result in death, severe bodily injury or extensive property damage. • For emergency-stop applications, either the integrated function for restart interlock must be used or automatic restarting of the machine must be...
Open the catalog to page 6DN3PD1 Important notes and validation 4.1. Function Description • The two-channel control monitor of the safety switch-gear module measures the frequency of the effective rotating field of the motor at the measuring terminals L1, L2 and L3, • An undercut or an exceeding of the configured switching threshold frequency (V-LIMIT 1 and V-LIMIT 2) an internal or an external error opens immediately the enabling circuits 13/14, 23/24. The unit is in safe switching status • There is a load depending slip between motor speed and rotating field frequency if an asynchrony motor is used. This must be...
Open the catalog to page 75 Usage 5.1. Operation with frequency converter • An operation at electrical power drive systems with adjustable speed is possible. (Frequency converter) • The monitored frequencies can be configured at the module • The safety switch-gear module switches off the output contacts, if the effective rotating field frequency is outside of the adjusted switching threshold frequency 5.2. Operation at motors with star-triangle • Motor with star-triangle circuit • The operation with star-triangle circuit or pole changeover is possible. • The Terminals L1 and L3 have to be directly connected to as...
Open the catalog to page 8• Mounting on 35mm DIN rail according to EN 60715 • For the replacement pull the lock device using a screwdriver • Meeting the pitch according to DIN EN 50274, VDE 0660-514. • No strong magnetic fields in the installation vicinity. • These can interfere with the unit. • Magnetic fields < 30 A/ m • Wires with cross section of 1.5 mm2 are to use. • Copper wires up to 60°C/75°C approved are obligatory. • Using of wire end sleeve is required. • Loads connected to the measuring wires are not allowed. • The laying of the measuring wires has to avoid a cross connection or short. Laying in cable...
Open the catalog to page 9DN3PD1 Configuration of the switching threshold 7.1. Important notes to the Configuration • To activate the SET-button use an isolated screwdriver according to EN 60900 to use. • Activate the SET button to display the present adjustments. The adjustments are displayed one after the other. • The correct configuration of the switching threshold and the quit-function is the requirement for a safe function and is in the responsibility of the user. • The output contacts are switched-off during the configuration. • No saving of the parameters by voltage break or break of the configuration for...
Open the catalog to page 10DN3PD1 Configuration of the switching threshold Reaction time: monitored frequency 5Hz, ca. 200ms, 1 Hz, ca. 1s. Original Instruction Manual 04/18 Date: 2018-02-20 11 of 16
Open the catalog to page 11DN3PD1 Configuration of the switching threshold 12 of 16 Date: 2018-03-13 Original instruction manual 04/18
Open the catalog to page 128 Diagnostics • At the 2-colors 4 LED (b1, b2, b3, b4) will be displayed the ready function, switching status, internal and external error. • This happens also by the semi-conductor outputs O1 and O2. Original Instructio
Open the catalog to page 1314 of 16 Date: 2018-03-13 Original instruction manual 04/18
Open the catalog to page 14Contact current load Load kind resistive Load Inductive Load Loads with high capacitive part ruin the output contacts because the switch current is very high. DC Schaltstrom (A) / DC Switching current (A) 10 Original Instruction Manual 04/18
Open the catalog to page 15All DINA Elektronik GmbH catalogs and technical brochures
-
SAFEONE DN3PD2
42 Pages
-
SAFELINE VARIO
71 Pages
-
DN3PW: 3 phase monitor
8 Pages
-
DNSR 2R2: emergency stop relays
16 Pages
-
DNDS modular product overview
40 Pages
-
DNDS modular
31 Pages
-
dn3pwe
3 Pages
-
dn3ps2e
8 Pages
-
dnco1
8 Pages
-
slvariobriefdescription
12 Pages
-
safelinehardwaresld2e
51 Pages