XP-3110 XP-3160

XP-3110 XP-3160

Product catalog summary
Overview: This document provides technical specifications and features for two models of combustible gas detectors, XP-3160 and XP-3110, designed for detecting various combustible gases and vapors using catalytic combustion sensors.
Specifications:
  • Gas Detected: Both models detect combustible gases and vapors. Users must specify the type of gas, such as Methane, Isobutane, Propane, Ethanol, Hydrogen, Acetylene, etc.
  • Detection Principle: Catalytic combustion.
  • Sampling Method: Extractive.
  • Detection Range: XP-3160: 0-5,000ppm or 0-10,000ppm; XP-3110: 0-100%LEL.
  • Indication Accuracy: XP-3160: ±5% (H range), ±10% (L range); XP-3110: ±5% of full scale.
  • Alarm Set Value: XP-3160: 250 or 500ppm; XP-3110: 20%LEL.
  • Display: LCD digital with backlight, auto range changeover.
  • Alarm Indication: Intermittent buzzer and red lamp flashing for gas and trouble alarms.
  • Explosion-Proof Structure: Exibd ⅡBT3.
  • Operation Temperature: -20 to 50℃.
  • Power Source: 4×AA alkaline dry cells, up to 20 hours of battery life.
  • Dimensions and Weight: W82×H162×D36mm, approx. 450g (excluding batteries).
  • Accessories: Standard accessories include a soft case, gas sampling hose, probe with filter/moisture trap, and spare filters. Optional accessories include a gas sampling hose (2-30m), gas dilution probe, and data download software.
Features:
  • High sensitivity detection with a measuring range of 0-500ppm (XP-3160) and 0-10/0-100%LEL (XP-3110).
  • Lightweight and compact design.
  • Built-in correction factors for up to 5 flammable gases (factory option).
  • Suitable for monitoring explosion risks and measuring toxic and combustible gases in the ppm range.
Certifications: Both models are type approved by Class NK (NK) No.06T605, with designation required.
See more

Catalog excerpts

XP-3110 XP-3160-1

Combustible Gas Detectors Detect Combustible Gases in General with High Sensitivity For measurement of combustible gas concentration of 0-10/0-100% LEL. Type of Gas Detected XP-3110 XP-3110Please make your specification by filling in the type of a gas. Ex: Methane, Isobutane, Propane, Ethanol, Hydrogen, Acetylene, etc. Detection Principle Combustible Catalytic combustion gas sensor Features ● For measurement of combustible gas concentration of 0-10/0-100%LEL. ● Suitable for monitoring a risk of explosion. ● New digital display with a simulated analog scale. ● Built-in correction factors for up to 5 flammable gases.(factory option) Specifications Model Gas Detected (Designation required) Type approved by Class NK (NK) No.06T605 (Designation required) XP-3110 Combustible gases and vapors (specify gas to be detected) Catalytic combustion Extractive 0-100%LEL Detection Principle Sampling Method Detection Range Indication Accuracy ±5% of full scale (Under identical conditions) Alarm Set Value 20%LEL LCD digital (with backlight) Digital display: 0-100%LEL Display Digital bar display: Auto range changeover 0-10%LEL (L range) 0-100%LEL (H range) Gas alarm: Intermittent buzzer, Red lamp flashing Alarm Indication Trouble alarm: Buzzer, Red lamp flashing, LCD display Explosion-Proof Structure Exibd ⅡBT3 Operation Temperature −20 to 50℃ Power Source 4×AA alkaline dry cells Battery Life *1 Up to 20 hours Dimensions W82×H162×D36mm Weight Approx. 450g (16oz.) (excluding batteries) Soft case, 4×AA alkaline dry cells, Gas sampling hose (1m), Probe with Standard Accessories filter/moisture trap, spare filters 2-30m gas sampling hose, Gas dilution probe, Data download software (CDOptional Accessories ROM software and USB cable) *1 Battery life may vary with ambient conditions, conditions of use, storage period, battery manufactures, etc. Super-sensitive and best suited for detecting gases in ppm range. Type of Gas Detected XP-3160 XP-3160Please make your specification by filling in the type of a gas. Ex: Methane, Isobutane, Propane, Ethanol, Hydrogen, Acetylene, Toluene, o-Xylene, Benzene, etc. Detection Principle Combustible Catalytic combustion gas sensor Features ● High sensitivity detector with 0-500ppm measuring range (Standard). ● Best suited for measuring toxic and combustible gases in the ppm range. ● Lightweight 450g (16 oz.) and compact. ● Built-in correction factors for up to 5 flammable gases.(factory option) Specifications Model XP-3160 Combustible gases and vapors (specify gas to be detected) Detection Principle Catalytic combustion Sampling Method Extractive Detection Range 0-5,000ppm or 0-10,000ppm Indication Accuracy H range: ±5% (Under identical conditions) L range: ±10% 250 or 500ppm Alarm Set Value LCD digital (with backlight) Digital display: 0-5,000ppm or 0-10,000ppm Digital bar display: Auto range changeover Display 0-500ppm or 0-1,000ppm (L range) 0-5,000ppm or 0-10,000ppm (H range) Gas alarm: Intermittent buzzer, Red lamp flashing Alarm Indication Trouble alarm: Buzzer, Red lamp flashing, LCD display Explosion-Proof Structure Exibd ⅡBT3 Operation Temperature −20 to 50℃ 4×AA alkaline dry cells Power Source Up to 20 hours Battery Life *1 W82×H162×D36mm Dimensions Approx. 450g (16oz.) (excluding batteries) Weight Soft case, 4×AA alkaline dry cells, Gas sampling hose (1m), Probe with Standard Accessories filter/moisture trap, spare filters 2-30m gas sampling hose, Gas dilution probe, Data download software (CDOptional Accessories ROM software and USB cable). Gas Detected (Designation required) Type approved by Class NK (NK) No.06T605 (Designation required) *1 Battery life may vary with ambient conditions, conditions of use, storag

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.