OILPORT 20 SET

OILPORT 20 SET

OILPORT 20 SET

Product catalog summary
General Specifications:
The OILPORT 20 SET is a hand-held device designed for measuring moisture in mineral and synthetic oils. It features a resolution for moisture measurement of aw: 0.001 or 0.01...1ppm, depending on the measuring range, and a temperature measurement resolution of 0.1°C or 0.1°F. The device operates on four 1.5V AA alkali-manganese batteries, providing a battery life of 200 hours. It functions within a working temperature range of 0 to 50°C (32 to 122°F) and complies with CE standards EN50081-2, EN50082-2, EN55011, EN61000-4-2, and EN61000-4-3. The housing is made of ABS with an IP40 protection class, and the device dimensions are 145 x 85 x 37 mm, weighing approximately 400g. The display is an illuminated LC display measuring 90 x 50 mm.
Technical Data - Display Unit:
The display unit measures temperature (T), water activity (aw), and oil-specific parameters (x). It includes features such as HOLD, MIN, MAX, AVG readouts, a real-time clock, and selectable SI/US units. Users can recalibrate the device, which is suitable for measuring moisture in both mineral and synthetic oils.
Typical Applications and Features:
The OILPORT 20 SET is designed for industrial environments, offering robust housing and pressure-tight or short measuring probes. It measures water activity and temperature to calculate water content in oils, with accuracies traceable to international standards. The device is available with optional calibration devices and carrying cases.
Model Probes and Calibration Set:
The device can be equipped with different probes, including pressure-tight oil probes (1/2” ISO or 1/2” NPT) and short oil probes. The working range for these probes is 0 to 1 aw, 0 to 20000ppm, and -40 to 120°C. The accuracy is ±0.02aw for 0 to 0.9aw and ±0.03aw for 0.9 to 1aw, with a response time of ≤ 10 minutes in still oil. Temperature dependence is ±0.0003aw/°C.
Scope of Supply:
The OILPORT 20 SET includes a display unit (OMNIPORT 20), an oil probe, a 2m probe cable, a protection sleeve for the sensing head, a carry case, and a calibration kit with humidity standards (10% and 80% RH) and an accredited calibration certificate. Additional accessories include calibration ampoules, a 5m probe cable, and various oil probes.
See more

Catalog excerpts

OILPORT 20 SET-1

To measure moisture in oil with a hand-held, user-friendly instrument requires extraordinary measurement technology. The hand-held meter OILPORT 20 meets these multiple demands and is available with a pressure-tight or short measuring probe. The robust housing of the OILPORT 20 allows usage in harsh industrial environments. The physical quantities measured are water activity aw and temperature T. With these quantities OILPORT 20 SET calculates the water content (ppm) in mineral transformer oils. Calculation of water content in non-mineral transformer oils and parameters of the oil. The carrying cases can accommodate the measuring equipment with optional calibration devices. The accuracies of the measured values are traceable to international standards, administrated by NIST, PTB, BEV... Typical Applications measurands: T, aw, x input of specific oil parameters HOLD / MIN / MAX / AVG readout real time clock SI/US units selectable recalibration by user Measurement of moisture in mineral and synthetic oil Technical Data - Display unit General moisture measurement: aw: 0.001 [ ] or 0.01...1ppm (depending on measuring range) temperature measurement: 0.1°C; 0.1°F 4x 1.5V AA alkali-manganese battery 200h display unit and grip of sensing probe: 0...50°C (32...122°F) EN50081-2 EN50082-2 EN55011 EN61000-4-2 EN61000-4-3 ABS / IP40 145 x 85 x 37 mm (5.7 x 3.3 x 1.5”) ca. 400g (1lbs) LC display, 90 x 50 mm (3.5 x 2”), illuminated Supply voltage Battery lifetime Working temperature range CE compatibility according Housing / protection class Dimensions (HxWxD) Weight Display Application: Working range: Accuracy: measurement of moisture in mineral and synthetic oil 0...1 a / 0...20000ppm / -40...120°C (-40...248°F) ±0.02aw (0...0.9aw), ± 0.03aw (0.9...1aw) ±0.2°C / ±0.36°F (20°C / 68°F), ±0.5°C / ±0.9°F (-40 resp. 120°C / -40 resp. 248°F) Response time τ : ≤ 10 min (in still oil) Pressure range: 0.01...20bar (0.15...300psi) Measurand: channel 1: T [°C/°F] channel 2: aw [ ] or x [ppm] oil specific parameters are adjustable at the basic device Temperature dependence: aw: ±0.0003aw/°C

 Open the catalog to page 1
OILPORT 20 SET-2

Application: Working range: Accuracy: measurement of moisture in mineral and synthetic oil 0...1 a / 0...20000ppm / -40...120°C (-40...248°F) ±0.02aw (0...0.9aw), ± 0.03aw (0.9...1aw) ±0.2°C / ±0.36°F (20°C / 68°F), ±0.5°C / ±0.9°F (-40 resp. 120°C / -40 resp. 248°F) Response time τ : ≤ 10 min (in still oil) Measurand: channel 1: T [°C/°F] channel 2: aw [ ] or x [ppm] oil specific parameters are adjustable at the basic device Temperature dependence: aw: ±0.0003aw/°C (aw/°F) w Display unit type OMNIPORT 20 (including a set of 4 AA batteries) Oil probe Probe cable type HA010813, 2m (6,6ft) Calibration...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.