1. Catalogs
  2. DIEHL Metering
  3. ultrasonic volume measuring components SHARKY / model 473/474

ultrasonic volume measuring components SHARKY / model 473/474

ultrasonic volume measuring components SHARKY / model 473/474

ultrasonic volume measuring components SHARKY / model 473/474

Product catalog summary
Overview: The document provides technical specifications and features of the Ultrasonic Flow Sensor sHarKY fs, models 473 and 474, designed for measuring flow in heating and cooling systems using ultrasonic technology.
Specifications:
  • Static flow sensor with a dynamic range of qi/qp: 250 in class 2, with nominal flow rates ranging from 0.6 to 25 m3/h.
  • Temperature range: 5°C to 90°C, with overload temperature up to 150°C for certain sizes.
  • Pressure loss diagram and measuring accuracy conforming to EN 1434 class 2.
  • Available in various nominal sizes and pressure ratings (PN 25).
Features:
  • Patented free-beam principle ensuring swirl-free flow and lower pressure loss.
  • Robust stainless steel reflector and no need for calming sections in installation.
  • Battery options include a 3.0V DC lithium battery with a typical 12-year lifespan or external power supply options.
  • Pulse output options with galvanic isolation available for model 474.
Special Features:
  • NOWA test capability and connection to calculators with pulse-defined values.
  • Insensitive to magnetite and can be installed in any position.
  • HYDRO-SET parameterization software for customization.
Power Supply:
  • Model 474: Standard 3.0V DC lithium battery, optional 3.6V DC battery, or main supply of 24V AC or 230V AC.
  • Model 473: Standard 3.0V DC lithium battery, with external supply options.
Pulse Output:
  • Model 474: Standard mounted module with galvanic isolation, pulse values from 1ml to 5000l.
  • Model 473: Two pulse outputs for volume and testing, with high-resolution test impulse capability.
Technical Data:
  • Nominal sizes, flow rates, and pressure loss values are detailed for various configurations.
  • Operating pressure maximums and temperature ranges are specified for different models.
Ordering Information:
  • Options for nominal flow, pressure, verification, pulse cable length, power supply, and pulse output type.
  • Configuration sheet for meter setup and customization.
See more

Catalog excerpts

ultrasonic volume measuring components SHARKY / model 473/474-1

Static flow sensor using ultrasonic technology Highly accurate flow sensor for flow measuring in local and district heating / cooling systems > 1st. approval in Europe for ultrasonic flow sensor with dynamic rage of qi/qp 1:250 in class 2 (qp 1.5 / 2.5 / 6 / 10 / 15 m > 3 /h) > EN 143422.5606.01 MID approval complete dynamic range: ≥ 1:1500 > DE-07-MI004-PTB022 Lithium battery with a lifetime of typical 12 years (16 years optional for the model 474) or external supply > Available for cooling application (model 474) Temperature range 5C - 90аC / 130C / 150аC Overload temperature up to 150 C (sizes q > p 0.6 up to 2.5m > 3 /h) Available in nominal sizes q > p 0.6 / 1.0 / 1.5 / 2.5 / 3.5 / 6 / 10 / 15 / 25 m > 3 /h Patented free-beam principle swirl-free flow around reflector lower pressure loss Robust stainless steel reflector All sizes also available in PN 25 approval according EN1434 class 2 and 3 No calming sections necessary in the inlet and/or outlet (Standard installation) > CEN CI 2SHARKY NOWA test capability > 6420-2-4-60,010,1110 Connection to calculator with pulse defined values insensitive against magnetite installation in any position free selectable pulse values from 1ml HYDRO-SET parameterization software on Windows basis guarantees optimum adaptation to the userВs specific needs > [q/qp] DATASHEET 1 size="-1">

 Open the catalog to page 1
ultrasonic volume measuring components SHARKY / model 473/474-2

The standard battery is a 3.0V DC lithium battery with a lifetime of 12 years. It can be also applied with a 3.6V DC lithium battery with regulator for a lifetime of 16 years, or with a main supply of 24V AC or 230V AC. These power supply can also be retrofitted in the field.Characteristics for main supply :230V AC or 24V AC main supply module The pulse output for the model 474 is realised with a stand-ard mounted module. The module has a galvanic isolation. (Fig. 1)There could be connected a pulse cable to the terminal onthese module, with a maximumcable leugth of 10m.The technical information...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.