Catalog excerpts
ELECTRONIC METER | MULTI-JET Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up ► Electronic sensor control for recording flow rate ► Lithium battery, lifetime 10 years ► Optical ZVEI interface equipped as standard ► Adjustable reading date for billing ► Single-line 7-digit display for easy meter reading
Open the catalog to page 1ELECTRONIC METER | MULTI-JET ELECTRONIC - BASIC FEATURES IP 54 or IP 68 for cold and warm water meter Optical ZVEI M-Bus, L-Bus, pulse Ambient class Protection class Interfaces standard Interfaces optional* * Possible combinations - M-Bus / pulse - L-Bus / forward pulse - only M-Bus Note: HYDRO-SET Software for configuration of meters, readout of measured values and printout of meter logs. Available under www.hydrometer.de (Products - downloads) TECHNICAL DATA DISPLAY Display indication Total values Values displayed Flow rate SUPPLY VOLTAGE Operating voltage UN VDC 3.0 (lithium battery)...
Open the catalog to page 2ELECTRONIC METER | MULTI-JET VOLUME- / PULSE Output type Max. voltage drop at active Max. current through inactive Max. reverse voltage without destroying outputs Open collector HYDROMETER GmbH ■ Postfach 1462 ■ 91505 Ansbach Subject to technical adjustments
Open the catalog to page 3ELECTRONIC METER | MULTI-JET Temperature range Ambient operating temperature Ambient storage temperature Nominal pressure Mounting position Metrological class °C 30 (for cold water meter) / 90 (for warm water meter) TECHNICAL DATA Nominal diameter Nominal flow rate Nominal flow rate Overall length Overload flow rate Transition flow rate Minimum flow rate Maximum flow rate (short-term) Transition flow rate Minimum flow rate Starting flow rate Flow rate at 0.1 bar pressure HYDROMETER GmbH ■ Postfach 1462 ■ 91505 Ansbach Subject to technical adjustments
Open the catalog to page 4ELECTRONIC METER | MULTI-JET Nominal flow rate Nominal flow rate Overall length Overall length with coupling Connection thread on meter Connection thread of coupling Weight without coupling Weight with coupling PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph HYDROMETER GmbH ■ Postfach 1462 ■ 91505 Ansbach Subject to technical adjustments
Open the catalog to page 5ELECTRONIC METER | MULTI-JET Temperature range Ambient operating temperature Ambient storage temperature Nominal pressure Mounting position Metrological class °C 30 (for cold water meter) / 90 (for warm water meter) TECHNICAL DATA Nominal diameter Nominal flow rate Nominal flow rate Overall length Overload flow rate Transition flow rate Minimum flow rate Maximum flow rate (short-term) Transition flow rate Minimum flow rate Starting flow rate Flow rate at 1 bar pressure loss HYDROMETER GmbH ■ Postfach 1462 ■ 91505 Ansbach Subject to technical adjustments
Open the catalog to page 6ELECTRONIC METER | MULTI-JET Nominal diameter Nominal flow rate Nominal flow rate Overall length Overall length with coupling Connection thread on meter Connection thread of coupling Flange diameter Hole circle diameter Screwhole diameter Weight without coupling Weight with coupling Weight with flanges PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph HYDROMETER GmbH ■ Postfach 1462 ■ 91505 Ansbach Subject to technical adjustments
Open the catalog to page 7ELECTRONIC METER | MULTI-JET Temperature range Ambient operating temperature Ambient storage temperature Nominal pressure Mounting position Metrological class °C 30 (for cold water meter) / 90 (for warm water meter) Rising pipe, downpipe TECHNICAL DATA Nominal diameter Nominal flow rate Nominal flow rate Overall length Overload flow rate Transition flow rate Minimum flow rate Maximum flow rate (short-term) Transition flow rate Minimum flow rate Starting flow rate Flow rate at 1 bar pressure loss HYDROMETER GmbH ■ Postfach 1462 ■ 91505 Ansbach Subject to technical adjustments
Open the catalog to page 8ELECTRONIC METER | MULTI-JET Nominal flow rate Nominal flow rate Overall length Overall length with coupling Connection thread on meter Connection thread of coupling Weight without coupling Weight with coupling PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph HYDROMETER smart in solutions HYDROMETER GmbH ■ Postfach 1462 ■ 91505 Ansbach Subject to technical adjustments 15.02.2013 9
Open the catalog to page 9All DIEHL Metering catalogs and technical brochures
-
AERIUS
2 Pages
-
CORONA_DP_405
5 Pages
-
AQUILA V3 DIN
3 Pages
-
AQUARIUS S / RS / P - MID
3 Pages
-
CORONA E
9 Pages
-
AQUILA V4
3 Pages
-
CORONA MDI 110
5 Pages
-
CORONA DP 405
5 Pages
-
ALTAIR V4
3 Pages
-
WESAN ST 215
3 Pages
-
IZAR DOSING
2 Pages
-
IR PULSE TRANSMITTER 573
3 Pages
-
REED SWITCH 570
3 Pages
-
IZAR PULSE H
2 Pages
-
SIGNAL CONVERTER 520.11
4 Pages
-
WESAN WP HE CHECK 725
3 Pages
-
WESAN WP H 225
3 Pages
-
WESAN WPV A 226/216
3 Pages
-
ALTAIR V3
3 Pages
-
CORONA ST 130
3 Pages
-
CORONA P 423/424
5 Pages
-
CORONA MCI COMPOSITE 108
3 Pages
-
AQUARIUS S/RS/P
3 Pages
-
Wesan WB E
5 Pages
-
HYDRUS
8 Pages
-
ALTAIR MCI 119
3 Pages
-
WESAN WB 234
3 Pages
-
WESAN WS 233
3 Pages
-
Corona ER
8 Pages
-
WESAN HP 225
3 Pages
-
Altair
3 Pages
-
Wesan
4 Pages
-
SHARKY Model 775
6 Pages
-
Sharky Model 773
10 Pages
-
Ray Model
12 Pages
-
energy calculator ENERGY-INT6
11 Pages
-
bulk water meter model 725
2 Pages
-
dry runner sheet model 118
2 Pages