The CORONA DP 405 is a multi-jet meter designed for proportional control of pumps and motors, and for remote transmission of flow rates. It is suitable for both horizontal and rising pipe installations.
Features
  • Dry-running design with magnetic coupling to prevent sediment faults.
  • Waterproof, rotatable counter for easy reading.
  • Built-in pulse contact with a 2-meter cable, housed in a waterproof enclosure.
  • Maximum contact load of 24 V (SELV) 0.2 A.
  • Outlet prepared for a DVGW-approved non-return valve.
  • Special hard nickel-plated version available.
General Specifications
  • Medium temperature range: 0 to 30°C, with safety up to 90°C.
  • Ambient storage temperature: 0 to 55°C.
  • Nominal pressure: 16 bar.
  • Display range: 0.05 liters to 99,999 m³.
  • Pulse values available: 0.25 to 1000 liters per pulse.
  • Accuracy class: A, Protection class: IP 65.
Technical Data for Horizontal Pipes
  • Nominal diameters: 20, 25, 40, 50 mm.
  • Nominal flow rates: 2.5 to 15 m³/h.
  • Maximum flow rates: 5 to 30 m³/h.
  • Transition flow rates: 250 to 1500 l/h.
  • Minimum flow rates: 100 to 600 l/h.
  • Starting flow rates: 20-90 l/h.
  • Flow rate at 1 bar pressure loss: 7 to 34 m³/h.
Dimensions for Horizontal Pipes
  • Overall lengths: 175 to 300 mm.
  • Connection threads: G1B to G2B.
  • Weights without coupling: 1.7 to 11.7 kg.
Technical Data for Rising Pipes
  • Nominal diameters: 20, 25, 40 mm.
  • Nominal flow rates: 2.5 to 10 m³/h.
  • Maximum flow rates: 5 to 20 m³/h.
  • Transition flow rates: 250 to 1000 l/h.
  • Minimum flow rates: 100 to 400 l/h.
  • Starting flow rates: 20-70 l/h.
  • Flow rate at 1 bar pressure loss: 6 to 22 m³/h.
Dimensions for Rising Pipes
  • Overall lengths: 105 to 200 mm.
  • Connection threads: G1B to G2B.
  • Weights without coupling: 2.1 to 5.5 kg.
Graphs
The document includes pressure loss and typical error graphs for both horizontal and rising pipe installations.
See more

Catalog excerpts

CORONA DP 405-1

MULTI-JET METER | DRY RUNNER Contact water meter for proportional control of pumps, motors, etc. and for remote transmission of flow rates. ► Multi-jet impeller meter in completely dry-running design with magnetic ► Only the impeller operates in the wet chamber to prevent faults due to ► Encapsulated waterproof counter. Reading not obstructed by condensation ► Counter can be rotated to any position for easy reading ► Built-in pulse contact (with cable 2 m) cast in a waterproof enclosure and easily replaceable Max. contact load 24 V (SELV) 0.2 A ► The outlet is prepared for installing a non-return valve (DVGW approved) ► Special version hard nickel-plated available

 Open the catalog to page 1
CORONA DP 405-2

CORONA DP 405Meter for horizontal pipes MULTI-JET METER | DRY RUNNER GENERAL Medium temperature range Meter for horizontal pipes 0 ... 30 Temperature safety Ambient storage temperature Nominal pressure Display range Pulse value* Accuracy class Protection class * Reed switch with luster terminal available. TECHNICAL DATA Nominal diameter Nominal flow rate Maximum flow rate (short-term) Transition flow rate Minimum flow rate Overall length with coupling Starting flow rate Flow rate at 1 bar pressure loss Nominal diameter Nominal flow rate Connection thread on meter (ISO 228/1) Connection thread...

 Open the catalog to page 2
CORONA DP 405-3

CORONA DP 405 Meter for horizontal pipes MULTI-JET METER | DRY RUNNER PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph HYDROMETER GmbH • Postfach 1462 • 91505 Ansbach Subject to technical adjustments

 Open the catalog to page 3
CORONA DP 405-4

CORONA DP 405Meter for rising pipes MULTI-JET METER | DRY RUNNER GENERAL Medium temperature range Meter for rising pipes 0 ... 30 Temperature safety Ambient storage temperature Nominal pressure Display range Pulse value* Accuracy class Protection class * Reed switch with luster terminal available. TECHNICAL DATA Nominal diameter Nominal flow rate Maximum flow rate (short-term) Transition flow rate Minimum flow rate Overall length with coupling Starting flow rate Flow rate at 1 bar pressure loss Nominal diameter Nominal flow rate Connection thread on meter (ISO 228/1) Connection thread of coupling...

 Open the catalog to page 4
CORONA DP 405-5

CORONA DP 405 Meter for rising pipes MULTI-JET METER | DRY RUNNER PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph HYDROMETER GmbH • Postfach 1462 • 91505 Ansbach Subject to technical adjustments

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.