DICTATOR Fire door control solutions

DICTATOR Fire door control solutions
1 / 80 PagesView full catalog

DICTATOR Fire door control solutions

Product catalog summary
Introduction to Hold-Open Systems
Hold-open systems are vital for fire safety in buildings, ensuring fire doors close automatically during a fire to prevent its spread. These systems keep doors open only when necessary for operational purposes.
Components and Functionality
A typical system includes a power supply, tripping device, fire detectors, an electromagnet, and a hand release switch. The central unit, like the RZ-24, powers and evaluates signals from fire detectors, triggering door closure during a fire.
Regulations and Compliance
Systems must comply with standards such as EN 14637. In Germany, specific approvals dictate installation requirements. Regular testing and maintenance are mandatory.
Installation and Maintenance
Qualified professionals must install and maintain these systems, with regular checks documented in a log book. Smoke and heat detectors should be replaced every eight years.
Training and Support
DICTATOR offers training for installation, maintenance, and compliance, along with advisory services to ensure legal and safety requirements are met.
Replacement and Upgrades
DICTATOR provides replacement components like RM 2000 and WM 3000+ detectors to facilitate maintenance without a complete system overhaul.
RZ-24 Central Unit Overview
The RZ-24 converts 230 VAC to 24 VDC to power detectors and electromagnets, initiating door closure during an alarm. It includes a RESET key and options for external release switches.
Technical Specifications
Operates on 85-265 VAC, consuming about 30 W, with a 24 VDC output and 0.9 A load capacity. Operating temperature ranges from -30°C to +40°C, with an IP rating of IP 64.
Functions and Features
Supports manual release, tripping by detectors, and RESET functions, with LED status indicators. Can accommodate additional components like relay circuit boards.
Installation and Order Information
Available in standard and larger casings, with various part numbers. Installation considerations include cable inlet positioning and additional detectors.
Additional Components
Optional components include a time relay circuit board, emergency power supply, and additional relay contacts.
Compliance and Standards
Meets EN 14637 standards and is approved by the German Institute for Building Engineering, supporting optical and acoustic signaling.
Smoke and Heat Detectors
RM 4000 and WM 4000 detectors are designed for fire protection closures, with specifications and features ensuring compliance with EN standards.
Installation and Maintenance
Detectors are wired with a 3.9 kΩ resistor in the last detector. Regular testing is required, with smoke detectors replaced every 8 years.
Explosion-Proof Systems
DICTATOR provides systems for hazardous areas compliant with ATEX directive 2014/34/EU, including components like the RZ-24 central unit and explosion-proof magnets.
Electromagnets and Counter Plates
Specifications for various electromagnets, including power consumption, holding force, and installation requirements, are provided. Compliance with EN 1155 standards is emphasized.
Door Sequence Selector SR 2000
Ensures correct closing order for double-leaf fire doors, with specifications for integration with door aesthetics and optional electromagnetic locking features.
HLS Thermal Bolting
Maintains the integrity of fire and smoke protection doors, activating at high temperatures to prevent dangerous gaps.
See more

Catalog excerpts

DICTATOR Fire door control solutions-1

Fire Door Control Solutions _Contents Hold-Open Systems - Introduction page 07.003.00 RZ-24 Central Smoke and Heat Detectors RM/WM 4000 Fire Detectors RM/WM 2000 page 07.025.00 and RM/WM 3000+, for replacement in existing systems Ex-Proof Hold-Open Systems page 07.029.00 Electromagnets and Counter Plates page 07.035.00 Accessories: Hand Switch page 07.071.00 Brackets for Magnets Door Sequence Selectors HLS Thermal Bolting page 07.079.00 © DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 NeusaB • Germany Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 20190613 Page 07.001.00 Subject to change without notice. Errors do not constitute claims for compensation for damages.

 Open the catalog to page 1
DICTATOR Fire door control solutions-2

Fire Door Control Solutions © DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 Neusäß • Germany Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected]

 Open the catalog to page 2
DICTATOR Fire door control solutions-3

Hold-Open Systems Summary, Regulations Depending on their use and size, buildings are divided into fire areas to prevent a possible fire from spreading in the whole building. As a matter of principle openings in the walls between the fire areas are not allowed. For this reason doors which connect the fire areas have to be approved fire protection closures which always close on their own, i.e. after every opening they close automatically. However, the normal course of operations often requires that doors stay open in order not to interfere with or even endanger the movement of people and material...

 Open the catalog to page 3
DICTATOR Fire door control solutions-4

Hold-Open Systems Summary, Regulations Hold-Open Systems - Structure and Functioning Fire doors are still often kept open by wooden wedges to make passing easier - although this is forbidden. In the case of a fire this wedging or blocking prevents the closing of the door. The safety of the object is no longer ensured, because nothing would hinder a fire from spreading. Installing a hold-open system which meets the demands is the only legal action to keep fire protection closures as long open as the normal use requires it and at the same time to ensure their reliable closing in the event of a...

 Open the catalog to page 4
DICTATOR Fire door control solutions-5

Hold-Open Systems Summary, Regulations Hold-Open Systems - Structure and Functioning, cont. As a matter of principle you can install a hold-open system on all fire protection closures according to the specification of the door manufacturer. They should always be installed when open fire protection doors essentially simplify the movements in the building. Due to the great importance of the faultless functioning of a hold-open system, only qualified persons may approve/accept, test and maintain it. A qualified person has to confirm the correct first placing into operation on a defined plate in...

 Open the catalog to page 5
DICTATOR Fire door control solutions-6

Installation Regulations In Germany the installation directives for fire detectors are to be found in the respective approval of the building authorities or the general type approval. In other countries apply the corresponding directives for hold-open systems. In case there exist no directives, in Europe the EN 14637 serves for orientation. In the following you will find the prescriptions about the number and the mounting position of fire detectors in Germany. The following diagrams will help you to choose the correct number of detectors. When in the following "ceiling detectors" are required,...

 Open the catalog to page 6
DICTATOR Fire door control solutions-7

Hold-Open Systems Summary, Regulations Installation Regulations, cont. Section A - A - B Width Wall opening A Line Height of ceiling Installation areas Min. number of above lower edge (b = b1 or b2) detectors required1) of lintel 1 h1 and/or a1+ a2 + b 2 ceiling and 3 as line 2, but b 1 lintel detector or swing door with door 2 ceiling detectors © DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 NeusaB • Germany Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 20190207 1 Depending on the door width more detectors may be necessary in the case of lines 1 and 2.

 Open the catalog to page 7
DICTATOR Fire door control solutions-8

Hold-Open Systems Summary, Regulations Electrical Installation, Other Prescriptions The installation of the hold-open system on site should be carried out by professionals who are familiar with all the necessary tasks, the corresponding local and national prescriptions and have the necessary certificates. They have to obey the installation instructions of the manufacturer of the components of the hold-open system. The technician as well as his company are responsible for the correct installation of the hold-open system. The same applies to handing over the acceptance documentation of the installation...

 Open the catalog to page 8
DICTATOR Fire door control solutions-9

RZ-24 Central Unit for — Hold-Open Systems The RZ-24 central unit is the core of the DICTATOR hold-open system. This one device combines all essential functions, so that in the simplest case you only have to connect fire detectors and electromagnets. - It changes the 230 VAC mains supply in 24 VDC for feeding the connected fire detectors and electromagnets. - It evaluates the signals of the fire detectors. - I n the event of an alarm or a failure it interrupts the power supply of the electromagnets and thus automatically initiates the closing of the fire/smoke door. - In case of an alarm or a...

 Open the catalog to page 9
DICTATOR Fire door control solutions-10

RZ-24 Central Unit for Hold-Open Systems RZ-24 Central Unit with Power Pack and Tripping Device The RZ-24 has been tested and approved by the Deutsches Institut für Bautechnik (German Institute for Building Engineering). It also meets the demands of the EN 14637. Due to its high performance (900 mA) even large hold-open systems can easily be operated by one central unit. As an option the RZ-24 central unit is available in a bigger casing (part no. 040554) (dimensions 202 x 152 x 90 mm). This offers enough room for additional components as e.g. relay circuit boards or an emergency power supply...

 Open the catalog to page 10
DICTATOR Fire door control solutions-11

RZ-24 Central Unit for Hold-Open Systems RZ-24 Central Unit - cont. The door approvals, standards and prescriptions of the accident prevention regulations/ safety at work may stipulate the optical and acoustical signalling of the closing. This is easily possible with the RZ-24. DICTATOR provides a signaller (part no. 700171) for this purpose which features besides the red LED warning flashlight also a siren which can be switched off - and an extremely low power consumption. In some countries as e.g. Austria it is prescribed that in underground car parks the warning signal has to start before...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.