
Access Control Systems _Contents Interlock Control System page 08.003.00 Door Locks, Electric Strikes, page 08.061.00 Access Control Systems page 08.067.00 24 VDC, 12 VDC Power Supplies page 08.069.00 UPS Power Supply © DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 NeusaB • Germany Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 20180126 Page 08.001.00 Subject to change without notice. Errors do not constitute claims for compensation for damages.
Open the catalog to page 1Access Control Systems. © DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 NeusaB • Germany Page 08.002.00 Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 20180126 Subject to change without notice. Errors do not constitute claims for compensation for damages.
Open the catalog to page 2In clean rooms, laboratories, hospitals etc. doors may often be opened only when others are closed. The DICTATOR interlock control system facilitates an easy configuration of these relations, without a complex PLC control system. The relations are "programmed" directly by DIP switches. Trained persons not requiring any special programming know-how can modify them on site at any time. For an easy mounting the components of the newest generation are connected as telephones or networks by cables with RJ45 connectors (exception: ex-proof version). The power pack for the 24 VDC supply is provided...
Open the catalog to page 3Interlock Control System DICTATOR Interlock Control System - General Information In the DICTATOR interlock control systems all doors of the interlock system are generally locked and are released only temporarily when the operating key of the terminal is pressed. This offers the highest possible safety within the interlock system. Every door is controled by a separate control board. With the peripheral system these are integrated in the control terminal of the respective door, with the central controllers RJ and SK the control boards of all doors forming part of the system are united in a central...
Open the catalog to page 4Interlock Control System DICTATOR Interlock Control System - General Information, cont. The terminals with piezo-type key and transponder of the peripheral and central RJ interlock control system can be combined at will, also on one door. Both models have the same dimensions. This allows, if necessary, to equip certain areas of the interlock system with an automatic access control without needing additional devices. The interlock system or parts of it can only be accessed by a restricted group of people. DICTATOR developed terminals for the interlock control system that feature an integrated...
Open the catalog to page 5Interlock Control System DICTATOR Interlock Control System - General Information, cont. The interlock control system is a very flexible system. Without needing a time-consuming new programmation, the complete interlock control system can easily be adapted to changing requirements. One of the main features of the DICTATOR interlock control system is the very easy "programming" of the relations between the doors. No computing skills at all are needed. All relations are adjusted by DIP switches. The peripheral version features these DIP switches directly in the control terminals. In the central...
Open the catalog to page 6Interlock Control System DICTATOR Interlock Control System - General Information, cont. The DICTATOR interlock control system is a modular system which can also integrate non-system components. Depending on the chosen version it also offers a great variety of additional possibilities. Some of the options mentioned in the following are not possible in the ex-proof version of the system or the system for switch range SP. Details about these two versions and the possible options can be found beginning on page 08.027.00 respectively 08.037.00. Locking Devices To lock interlock doors bar magnets,...
Open the catalog to page 7Interlock Control System DICTATOR Interlock Control System - General Information, cont. Depending on the type (peripheral, central, ex-proof) the system can be combined to different extents with facility management systems and a large number of additional functions can be achieved. The standard version of the DICTATOR interlock control system (peripheral or central RJ) is very easy to mount and connect. No specialist is needed. All intrasystem components are connected by flat cables with RJ45 connectors. Also the power pack is ready for plug-in in a 230 VAC socket. Discretion Circuit The interlock...
Open the catalog to page 8Interlock Control SystemInterlock Control System - Programming The following matrix helps you to determine the position of the DIP switches on the control boards. Just mark for each door which other door(s) may be open at the same time and which one(s) must stay locked (see example below). There are 3 positions for the DIP switches: Position +: defines the door for which the relations are set (basis door) Position -: this door is locked as long as the "basis door" is open. Position 0: this door can be opened even though the "basis door" is open, too. Clean room Required relations (determined...
Open the catalog to page 9Interlock Control System DICTATOR Interlock Control System - Summary On the following pages you will find detailed information about the different types of the DICTATOR interlock control system and the components which can be used for upgrading the peripheral as well as the central version. Peripheral interlock control system Overview Components Control terminals ST3 Operating terminals BT3 Distribution box Connection cables Order information Central interlock control system Overview page Components page Central controller RJ page Operating terminals BTZ page Operating terminals BT3...
Open the catalog to page 10Interlock Control System Peripheral System Peripheral Interlock Control System Overview The peripheral DICTATOR interlock control system is the most flexible type of the interlock control systems. Its modular structure offers the possibility to meet an extraordinary number of special requirements. All intrasystem components are connected by pluggable cables. Except for the alimentation these are flat cables with RJ45 connectors. The peripheral interlock control system has been designed for up to 8 doors respectively 8 groups of doors of maximum 8 doors each. Basic Set-up The basic set-up of the...
Open the catalog to page 111 Page
116 Pages
52 Pages
24 Pages
88 Pages
72 Pages
116 Pages
72 Pages
80 Pages
4 Pages
16 Pages