VarioLab+ instruments Modules for superstructures We present to you a new collection/line of VarioLab+ modules, based on the knowledge gained from more than twenty-five years of experience in the production of VarioLab+ devices and based on the comments of several thousand users from all over the world of VarioLab+ workplaces. The modules have been completely redesigned and innovated with new functions and elements, all in the spirit of modern needs. Great emphasis during development was placed on the safety of all devices, and along with that, their ergonomics were also improved. With the new...
Open the catalog to page 3VarioLab+ instruments Modules for superstructures In addition to the improved parameters, the optical interaction between the user and the device was also improved by signaling individual device states, and a clear indication of the output voltages on the terminals or compressed air outputs was added. The indication makes working with the devices clearer and the user has clear information about the use of a specific output of the device without searching. This makes work more comfortable and safer. Introduction and basic information on how to choose modules for superstructures Instrument modules...
Open the catalog to page 4Plug and outlet power modules M02 module 2 pcs outlet type „E“, 230 V, 50 Hz, 16 A M07 module 3 x 24 V AC output terminal module with 3 phase circuit breaker M19 module 3 phase 400 V safety output terminal module M20 module 3 phase outlet 16 A with switch M21-06 module 2 pcs single outlet type „E“, 230 V, 50 Hz, with its own circuit breaker 6 A M21-10 module 2 pcs single outlet type „E“, 230 V, 50 Hz, with its own circuit breaker 10 A M25-10 module 3 phase outlet, switch, circuit breaker 3 * 10 A, indicator lights M25-16 module 3 phase outlet, switch, circuit breaker 3 * 16 A, indicator lights...
Open the catalog to page 5VarioLab+ instruments CategoryModuleFixed DC (direct current) voltage source modules M04 DC source module ± 15 V / 1 A M43 module DC stabilized source ± 24 V / 1 A M47 module of unstabilized unfiltered DC source 24 V / 4.5 A M53 module of unstabilized unfiltered DC source 6 - 12 - 24 - 48 V / 2.0 A M62 module of stabilized DC source 5 - 12 - 24 - 48 V / 2 A M99 module DC stabilized source 15 V / 5 A Modules of laboratory sources of DC (direct current) voltage M05 module DC laboratory adjustable source 1 * 0 32 V / 4.1 A; 5 V / 3 A M14 module of double DC laboratory reg source 2 * 0 32 V / 4.1...
Open the catalog to page 6VarioLab+ instruments CategoryModuleAC and AC/DC laboratory power supply modules M09 module of stabilized AC power supply 0 V 255 V / 1 A M44 module of stabilized AC power supply 0 V 255 V / 2 A Ml 27 module of stabilized AC/DC power supply 0 - 48 V AC, 0 - 5 A AC and 0 - 30 V DC, 0 - 4 A DC Measuring instrument modules M10 counter and function generator module M11 simple DC voltmeter and ammeter module M17 3 phase analog ammeters 3 * 20 A / 40 A module M23 circuit acustic tester module M26 TrueRMS digital multimeter module M34 single-phase analog ammeter module up to 15 A AC and voltmeter up...
Open the catalog to page 7CategoryModule Page Variable autotransformer modules M51 3 phase variable autotransformer module, 0 - 100% Uprim / 2A M52 variable autotransformer module 230 V / 2 A with AC / DC output M64 variable autotransformer module 230 V / 3 A with AC / DC output M75 variable autotransformer module 230 V / 6 A with AC / DC output M101 3 phase variable autotransformer module, 0 - 100% Uprim / 4A Modules of decades M71 resistance decade module M72 induction decade module M73 capacitance decade module M74 module of resistance, inductance and capacitance decade Modules of passive elements M77 1000 uF + 1000...
Open the catalog to page 8VarioLab+ instruments Covers M00 – cover 60 mm Description: Blanking cover for empty space. M01 – cover 120 mm Description: Blanking cover for empty space. Description: Blanking cover for empty space.
Open the catalog to page 9VarioLab+ instruments Covers M58 – cover 240 mm Description: Blanking cover for empty space.
Open the catalog to page 10VarioLab+ instruments Plug and outlet power modules M02 – module 2 pcs outlet „E“ 230 V, 50 Hz, 16 A Description: 2 outlets 230 V / 16 A protected by module M08 or module M32. The voltage is signaled by a LED light. Parameters supply voltage: maximum output current: dimensions (h x w): M07 – 3 x 24 V AC output terminal module with 3 phase circuit breaker Description: Output terminal module for connecting existing 3 x 24 V AC-Y distribution. A transformer/s can be supplied to realise the distribution (parameters must be specified). The output is switched by a contactor controlled by the M08 or...
Open the catalog to page 11VarioLab+ instruments Plug and outlet power modules M20 – module 3 phase outlet 16 A + switch Description: Module with three-phase outlet 16 A (5 pins), switch and indicator light. Voltage is applied via the internal terminal board. It is advisable to secure the module with a primary fuse module, for example the M18, M30, M32 module. The module is connected to the M08 or M32 module. When the superstructure is turned off, the module is turned off too. Parameters maximum operating voltage: maximum output current: dimensions (h x w): note: 3 x 400 V / 50 Hz 16 A 200 x 120 mm it is advisable to subordinate...
Open the catalog to page 12VarioLab+ instruments Plug and outlet power modules M25 – module 3 phase outlet, switch, circuit breaker 3 × 10 A, indicator lights Description: Three-phase outlet, switch, 3 indicator lights, protection with a three-phase circuit breaker. Voltage supply through the superstructure terminal block. The module is subordinate to the M08 or M32 module, it is switched off when the superstructure is switched off. Parameters maximum operating voltage: maximum output current: circuit breaker used: dimensions (h x w): M25–16 – module 3 phase outlet, switch, circuit breaker 3 × 16 A, indicator lights Description:...
Open the catalog to page 13VarioLab+ instruments Plug and outlet power modules M35 – module 1 pc single outlet 230 V + 1 pc PC outlet 230 V, 50 Hz, 16 A Description: Single-phase outlet and appliance single-phase outlet. The module is protected by the M08 module or the M32 module. The voltage in the outlets is signaled by a light. Parameters supply voltage: maximum output current: dimensions (h x w): M37–10 – module of double 3 phase safety outlets 3 × 400 V, circuit breaker 10 A, TOTAL STOP Description: Mains voltage source with circuit breaker and on-off control. The presence of voltage at the output outlets is indicated...
Open the catalog to page 142 Pages