UnoVolta catalogue - 1

Tutorial Panels Uno Volta Description and Purpose of Tutorial Panels Uno Volta Tutorial panels Uno Volta are used for teaching wiring and measurement of circuits, as well as experiments of wide range of applications from many fields of electrical engineering and electronics. Basically, these are autonomous panels and each panel is focused on a particular issue. Nevertheless, the individual panels can complement each other and thus form a wider connection. The Uno Volta panels are focused on practicing the principles of connecting, inventing the right connections and detecting circuit failures. They are therefore not designed for a physical connection of wires based on a real practice. For this purpose, the tutorial system is intended. The individual Uno Volta panels offer not only wiring of standard home socket and lighting circuits, but also house wiring with EIB / KNX, or Inels. Other panels include contactor combinations and controls for electrical turntable circuits, both single-phase and three-phase. Other panels demonstrate the function of home console, security systems, or feature and connection of data and telephone networks. Uno Volta panels complement electric motors in a wide range of designs. Students can learn about the connection and potential failures of DC motor, single-phase and three-phase motors. The power supply of the Uno Volta panels is mostly supplied with 230 V / 50 Hz from the mains via conventional power plug. The panel itself always contains certain electrical devices that are related to the problem. All inputs and outputs of all devices are plugged into the safety inlets and for security reasons all cords must be made with safety pins designed for a voltage of at least 230 VAC Cat II. In addition, some panels are equipped with a fault simulator which the teacher can activate by switches that are hidden beneath the lockable door. Thus, learning is getting a further dimension when students have to not only properly integrate the circuit, but also detect any malfunction of any of the devices. The Uno Volta panels are designed to be durable and to withstand a long-time usage during demanding operation of the school from electrical and mechanical points of view without any defects or damage. On the bottom side, they are fitted with rubber legs, so they can be operated in a horizontal position, simply laid on the school desk. If the workpiece is equipped with tables or perforated work-plates, the Uno Volta panels can be hung on them with the supplied hooks. The circuit connection in the vertical position simulates the real environment even better.

Open the catalog to page 1
UnoVolta catalogue - 2

Tutorial Fields Uno Volta ź Light sources and their comparison Security technology Socket circuits and faults in them Data transmission Home electrical wiring DC and AC electrical motors management Data and telephone wiring Simulation of faults in wiring Intelligent building control Safety First Students' safety is more than important when teaching electrical connections. All Uno Volta panels are for this purpose equipped with safety sockets to prevent the student from accidental contact with the live part of the connector. The cords equipped with safety pins only are used to connect...

Open the catalog to page 2
UnoVolta catalogue - 3

Tutorial Panels Uno Volta UV-100 Basic Tutorial Panel for Wiring of Home Installations The UV-100 tutorial panel is used to practice and make experiments with connection of basic heavy current classic type home distribution systems. This panel is supplied with 230 V / 50 Hz voltage from the power supply. This panel is equipped with a fault simulator that teacher can activate by switches beneath the lockable door. Electrical components: Motion sensor: Light fitting: Multi-function time relay: Switch: Switch: Dimmer: Switch button: Contact field with sockets: Circuit fault simulator: 120°,...

Open the catalog to page 3
UnoVolta catalogue - 4

Uno Volta Examples of connection ■ Connection of the home socket in TN-S and TN-C system. ■ Connection of a simple luminaire operated by switch ■ Connection of a simple luminaire and a power-operated socket ■ Connection of a simple luminaire with two-way control ■ Simple lamp with multi-point control ■ Connecting a simple luminaire with a dimmer ■ Connecting a simple luminaire with a motion sensor (PIR) ■ Connecting a simple luminaire with a multifunctional time switch ■ Connecting a device switched via the contactor Accessories: ■ Power cord ■ Operating Instructions Optional accessories ■...

Open the catalog to page 4
UnoVolta catalogue - 5

Tutorial Panels Uno Volta UV-101 Tutorial Panel for Basic Connecting of Light Sources The UV-101 tutorial panel is used to practice and make experiments during connection of basic types of light sources with bulbs and fluorescent lamps. This panel is supplied with 230 V / 50 Hz voltage from the power supply. Electrical components: Socket E27 Starter in socket Fluorescent lamp socket G24 / GX24 Electronic ballast with a dimmer for fluorescent lamps Condenser 1,5 Uf Condenser 2,5 Uf Choke 18 W

Open the catalog to page 5
UnoVolta catalogue - 6

Uno Volta Examples of connection ■ Connection of incandescent bulb ■ Connection of fluorescent lamp, assembly of circuit with individual elements (fluorescent lamp, starter, choke, condenser). ■ Connection of the fluorescent lamp with electronic ballast with regulation of the light intensity. ■ Possibility to compare the luminosity and efficiency of each light source with each other. ■ Possibility to compare the influence of compensatory condenser capacity to the power effect cos 0. ■ Possibility to combine the connection of elements with UV-100 and UV-102 tutorial panels. Accessories: ■...

Open the catalog to page 6
UnoVolta catalogue - 7

Tutorial Panels Uno Volta UV-102 Tutorial Panel for Connection of Light Supply with Discharge Lamps The UV-102 tutorial panel is an extension panel of UV-101 and is used to practice and make experiments with connecting light sources with halogen bulbs and lamps. This panel is supplied with 230 V / 50 Hz voltage from the power supply. Parts used Sleeves E27 Choke Electronic ballast Halogen bulb with socket E27, 50W Pressure sodium lamp E27, 70W Mercury lamp with a socket E27, 50W

Open the catalog to page 7
UnoVolta catalogue - 8

Examples of connection ◼ Connection of a fluorescent lamp with a halogen bulb ◼ Connection of a fluorescent lamp with a classic bulb ◼ Connecting of a lamp, assembling of a circuit with individual elements (choke, ballast) ◼ Possibility to compare the luminosity and efficiency of each individual light source between each other. ◼ The UV-101 panel can be also used for a similar comparison. Příslušenství: ◼ Napájecí šňůra 230V ◼ Návod k obsluze Doporučené příslušenství: ◼ Taška pro uskladnění panelu a jeho převoz ◼ Propojovací bezpečnostní kabely ◼ Náhradní žárovky a zářivky ◼ Soubor úloh...

Open the catalog to page 8

All Diametral a.s. catalogs and technical brochures

  1. Uno Volta

    2 Pages

  2. HBT–1050

    2 Pages

  3. VibraZero

    4 Pages

  4. VertiGO

    1 Pages

  5. VarioClick

    2 Pages

  6. VarioLAB+

    96 Pages