1. Catalogs
  2. DI NICOLA INFINAM
  3. Insulating monolithic joint

Insulating monolithic joint

Insulating monolithic joint

Insulating monolithic joint

Product catalog summary
Overview: The document discusses dielectric joints, which are primarily used to electrically isolate structures not involved in cathodic protection systems, such as impressed current and galvanic anodes. These joints can also be used in conjunction with such systems, especially in extensive and complex networks, to protect sections affected by stray currents and control interference.
Specifications: The metallic elements of standard production joints are connected with corner and butt welds, separated by a dielectric element, with upper and lower seals and internal resin coating. The special polymer resin in Di Nicola joints ensures air insulation standards of 5 MΩ and an electrical breakdown voltage of >= 5KV AC at a maximum operating temperature of 70°C.
Model Information: Model Name: Giunto 1800 - 10. Study Name: Studio 15 Bar. Chart Type: Static nodal stress. Deformation Scale: 5.
Development and Testing: Di Nicola has developed a new dielectric series for water, utilizing modern prototyping technologies to verify loads and stresses on the joint under pressure. The joints undergo hydraulic testing and are accompanied by EN 10204 31B certification.
Technical Sheets: Drawings and dimensions are indicative, and the firm reserves the right to make changes at any time without prior approval.
See more

Catalog excerpts

Insulating monolithic joint-2

GIUNTI DIELETTRICI / MONOLITIC JOINTS I giunti dielettrici generalmente vengono utilizzati al fine di isolare elettricamente ogni altra struttura estranea che non debba essere interessata da impianti di protezione catodica di tipo diverso quali quelli a corrente impressa e ad anodi galvanici . Talvolta, gli stessi vengono utilizzati in aggiunta a tali sistemi di prote- zione catodica , specialmente in reti molto estese e geome- tricamente complesse , rendendo fattibile la loro protezione da quei tronchi interessati dalle correnti vaganti dal resto delle strutture, e rendendo possibile il controllo...

 Open the catalog to page 2
Insulating monolithic joint-3

SCHEDE TECNICHE * Disegni e dimensioni solo indicativi. La Ditta si riserva di apportare modifiche in qualsiasi momento - Drawings and dimensions just indicative. Our Firm reserves the right to make changes at any time without previous approval