Application: Water pumping stations: - Acqueducts - Irrigation - Water process Size range: DN 200 - DN 1000 (NPS 8 - NPS 40) Seawater applications: - Chemical industries - Process industries Maximum working pressure: Temperature range: Flange accommodation: DN 200 - DN 1000: 40 bar , Class 300 at ambient temperature -10°C to +130°C (+50°F to +266°F) EN 1092-1 ASME B16.5 AWWAC207 Others on request EN 12266-1 API 569 General A.SA.R check valves can be mounted in horizontal, vertical and diagonal direction. features ( DN 400-1000 mm) . Working pressure range is available in 10/16/25 /40 Bar. Due...
Open the catalog to page 2A.SA.R. WAFWER TYPE 1 Axial disc HDPE/PTFE GJS400/500 EN 1563/Stainless steel/Ductile NiResist alloy Stainless steel GJS400/500 EN 1563/Stainless steel/Ductile NiResist alloy NBR/EPDM Our rm reserves the right to make any technical changes without any notice to the clien
Open the catalog to page 3Application : Water pumping stations: - Acqueducts - Irrigation - Water process Size range: DN 200 - DN 1000 (NPS 8 - NPS 40) Seawater applications: - Chemical industries - Process industries Maximum working pressure: DN 200 - DN 1000: 40 bar , Class 300 at ambient temperature Temperature range: -10°C to +130°C (+50°F to +266°F) Flange accommodation: EN 1092-1 ASME B16.5 AWWAC207 Others on request Tests: EN 12266-1 API 569 General CLA.SA.R Geeno Type check valves can be mounted in horizontal, vertical and diagonal direction. They are ideal valves to prevent back flow trough pumps in any conditions....
Open the catalog to page 4A.SA.R. FLANGED TYPE A Axial disc Body Spring GJS400/500 EN 1563/Stainless steel Ductile NiResist alloy HDPE/PTFE GJS400/500 EN 1563/Stainless steel Ductile NiResist alloy Stainless steel Our rm reserves the right to make any technical changes without any notice to the clien
Open the catalog to page 5CLA.SA.R Wafer type A B C D E NOTE: NP40 Bar and CLASS 300 on request CLA.SA.R Flanged type PN A B C D E NOTE: NP40 Bar and CLASS 300 on request Our firm reserves the right to make any technical changes without any notice to the cl
Open the catalog to page 6kv is the flow in m3/h of water, at an average temperature of 20°c, crossing the valve creating a headloss of 1 bar. HEADLOSS (Δp) Simplified formula: Δp headloss (meter of water columm ) Definitions: Δp headloos (bar) ρ density (for water, ρ=1) Q flow (m3/h) Kv flow coefficient (m3/h) Our firm reserves the right to make any technical changes without any notice to the client.